Volumn 34, Issue 3, 1999, Pages 471-477

Intradialytic serial vascular access flow measurements

Author keywords

Access thrombosis; Hemodialysis vascular access; Mean arterial blood pressure; Ultrasound dilution technique; Vascular access blood flow

Indexed keywords

ADULT; AGED; ARTICLE; BLOOD FLOW; CHRONIC KIDNEY FAILURE; CORRELATION FUNCTION; DILUTION; FEMALE; HEMODIALYSIS; HUMAN; MALE; MEAN ARTERIAL PRESSURE; MEASUREMENT; THROMBOSIS; ULTRAFILTRATION; VASCULAR ACCESS;

EID: 0032883478     PISSN: 02726386     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0272-6386(99)70074-0     Document Type: Article
Times cited : (51)

References (11)
  • 1
    • 85119817305 scopus 로고    scopus 로고
    • US Renal Data System: USRDS 1997 Annual Data Report
    • US Renal Data System: USRDS 1997 Annual Data Report Am J Kidney Dis 30 suppl 3 1997 S1 S152 National Institutes of Health, National Institute of Diabetes and Digestive and Kidney Diseases, Bethesda, MD
    • (1997) Am J Kidney Dis , vol.30 , Issue.suppl 3 , pp. S1-S152
  • 2
    • 0024787757 scopus 로고
    • Intimal fibromuscular hyperplasia at the venous anastomosis of PTFE grafts in hemodialysis patients
    • SH Swedberg BG Brown R Sigley TN Wight D Gordon S Nicholls Intimal fibromuscular hyperplasia at the venous anastomosis of PTFE grafts in hemodialysis patients Circulation 80 1989 1726 1736
    • (1989) Circulation , vol.80 , pp. 1726-1736
    • Swedberg, SH1    Brown, BG2    Sigley, R3    Wight, TN4    Gordon, D5    Nicholls, S6
  • 3
    • 0028886525 scopus 로고
    • Prolongation of hemodialysis access survival with elective revision
    • J Sands CL Miranda Prolongation of hemodialysis access survival with elective revision Clin Nephrol 44 1995 329 333
    • (1995) Clin Nephrol , vol.44 , pp. 329-333
    • Sands, J1    Miranda, CL2
  • 4
    • 0028793648 scopus 로고
    • Clinical measurement of blood flow in hemodialysis access fistulae and grafts by ultrasound dilution
    • TA Depner NM Krivitski Clinical measurement of blood flow in hemodialysis access fistulae and grafts by ultrasound dilution ASAIO J 41 1995 M745 M749
    • (1995) ASAIO J , vol.41 , pp. M745-M749
    • Depner, TA1    Krivitski, NM2
  • 5
    • 0024467709 scopus 로고
    • Prevention of hemodialysis fistula thrombosis. Early detection of venous stenosis
    • SJ Schwab JR Raymond M Saeed GE Newman PA Dennis RR Bollinger Prevention of hemodialysis fistula thrombosis. Early detection of venous stenosis Kidney Int 36 1989 707 711
    • (1989) Kidney Int , vol.36 , pp. 707-711
    • Schwab, SJ1    Raymond, JR2    Saeed, M3    Newman, GE4    Dennis, PA5    Bollinger, RR6
  • 6
    • 0002745499 scopus 로고    scopus 로고
    • DOQI Clinical practice guidelines for vascular access. Guideline 10: Monitoring dialysis AV grafts for stenosis
    • National Kidney Foundation DOQI Clinical practice guidelines for vascular access. Guideline 10: Monitoring dialysis AV grafts for stenosis Am J Kidney Dis 30 suppl 3 1997 S162 S164
    • (1997) Am J Kidney Dis , vol.30 , Issue.suppl 3 , pp. S162-S164
    • National Kidney Foundation1
  • 7
    • 0029048487 scopus 로고
    • Theory and validation of access flow measurement by dilution technique during hemodialysis
    • NM Krivitski Theory and validation of access flow measurement by dilution technique during hemodialysis Kidney Int 48 1995 244 250
    • (1995) Kidney Int , vol.48 , pp. 244-250
    • Krivitski, NM1
  • 10
    • 0028808026 scopus 로고
    • Novel method to measure access flow during hemodialysis by ultrasound dilution technique
    • NM Krivitski Novel method to measure access flow during hemodialysis by ultrasound dilution technique ASAIO J 41 1995 741 745
    • (1995) ASAIO J , vol.41 , pp. 741-745
    • Krivitski, NM1
  • 11
    • 0030250444 scopus 로고    scopus 로고
    • Access flow measured during hemodialysis
    • J Sands D Glidden C Miranda Access flow measured during hemodialysis ASAIO J 42 1996 M530 M532
    • (1996) ASAIO J , vol.42 , pp. M530-M532
    • Sands, J1    Glidden, D2    Miranda, C3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.