1
-
-
0022712534
-
Mathematical tools for spatial computations with biplane isocentric x-ray equipment
-
Wollschläger, H.; P. Lee, A. Zeiher, U. Solzbach, T. Bonzel, H. J. Just: Mathematical tools for spatial computations with biplane isocentric x-ray equipment. Biomed. Tech. 31 (1986), 101-116.
-
(1986)
Biomed. Tech.
, vol.31
, pp. 101-116
-
-
Wollschläger, H.1
Lee, P.2
Zeiher, A.3
Solzbach, U.4
Bonzel, T.5
Just, H.J.6
-
2
-
-
0022489418
-
Derivation of spatial information from biplane multidirectional coronary angiograms
-
Wollschläger, H.; P. Lee, A. Zeiher, T. Bonzel, H. J. Just: Derivation of spatial information from biplane multidirectional coronary angiograms. Med. Progr. Technol. 11 (1986), 57-63.
-
(1986)
Med. Progr. Technol.
, vol.11
, pp. 57-63
-
-
Wollschläger, H.1
Lee, P.2
Zeiher, A.3
Bonzel, T.4
Just, H.J.5
-
3
-
-
0024079712
-
Spatial orientation of segments of the coronary arteries evaluated from 100 coronary angiograms
-
Solzbach, U.; H. Wollschläger, A. Zeiher, B. Willer, A. Philipp, H. J. Just: Spatial orientation of segments of the coronary arteries evaluated from 100 coronary angiograms. IEEE Comp. Cardiol. (1989), 359-362.
-
(1989)
IEEE Comp. Cardiol.
, pp. 359-362
-
-
Solzbach, U.1
Wollschläger, H.2
Zeiher, A.3
Willer, B.4
Philipp, A.5
Just, H.J.6
-
4
-
-
0023224633
-
Three-dimensional reconstruction of moving arterial beds from digital subtraction angiography
-
Parker, D. L.; D. L. Pope, R. Van Bree, H. W. Marshall: Three-dimensional reconstruction of moving arterial beds from digital subtraction angiography. Comput. Biomed. Res. 20 (1987), 166-185.
-
(1987)
Comput. Biomed. Res.
, vol.20
, pp. 166-185
-
-
Parker, D.L.1
Pope, D.L.2
Van Bree, R.3
Marshall, H.W.4
-
5
-
-
0025111082
-
Validation of a new automatic system for biplane quantitative coronary arteriography
-
Büchi, M.; O. M. Hess, R. L. Kirkeeide, T. Suter, M. Muser, H. P. Osenberg, P. Niederer, M. Anliker, K. L. Gould, H. P. Krayenbühl: Validation of a new automatic system for biplane quantitative coronary arteriography. Int. J. Card. Imaging 1990; 5: 93-103.
-
(1990)
Int. J. Card. Imaging
, vol.5
, pp. 93-103
-
-
Büchi, M.1
Hess, O.M.2
Kirkeeide, R.L.3
Suter, T.4
Muser, M.5
Osenberg, H.P.6
Niederer, P.7
Anliker, M.8
Gould, K.L.9
Krayenbühl, H.P.10
-
6
-
-
0029133535
-
Analytic isocenter calibration - A new approach for accurate x-ray gantries
-
Wunderlich, W.; F. Fischer, T. Linderer, R. L. Kirkeeide: Analytic isocenter calibration - a new approach for accurate x-ray gantries. Angiology 46 (1995), 577-582.
-
(1995)
Angiology
, vol.46
, pp. 577-582
-
-
Wunderlich, W.1
Fischer, F.2
Linderer, T.3
Kirkeeide, R.L.4
-
7
-
-
0343310585
-
Accuracy and precision of the analytic calibration method in quantitative coronary angiography
-
Kristiansen, G.; W. Wunderlich, F. Fischer, B. Roehrig, H. R. Arntz, D. Horstkotte, H.-P. Schultheiss: Accuracy and precision of the analytic calibration method in quantitative coronary angiography. IEEE Comp. Cardiol. 23 (1996): 553-556.
-
(1996)
IEEE Comp. Cardiol.
, vol.23
, pp. 553-556
-
-
Kristiansen, G.1
Wunderlich, W.2
Fischer, F.3
Roehrig, B.4
Arntz, H.R.5
Horstkotte, D.6
Schultheiss, H.-P.7
-
8
-
-
0027885022
-
Biplane coronary angiography: Accurate quantitative 3D-reconstruction without isocenter
-
Wahle, A.; E. Wellnhofer, H. Oswald, E. Fleck: Biplane coronary angiography: accurate quantitative 3D-reconstruction without isocenter. IEEE Comp. Cardiol. (1993), 97-100.
-
(1993)
IEEE Comp. Cardiol.
, pp. 97-100
-
-
Wahle, A.1
Wellnhofer, E.2
Oswald, H.3
Fleck, E.4
-
9
-
-
0029327157
-
Assessment of diffuse coronary artery disease by quantitative analysis of coronary morphology based upon 3D-reconstruction from biplane angiograms
-
Wahle, A.; E. Wellnhofer, I. Mugaragu, H. U. Sauer, H. Oswald., E. Fleck: Assessment of diffuse coronary artery disease by quantitative analysis of coronary morphology based upon 3D-reconstruction from biplane angiograms. IEEE Trans. Med. Imaging 14 (1995), 230-241.
-
(1995)
IEEE Trans. Med. Imaging
, vol.14
, pp. 230-241
-
-
Wahle, A.1
Wellnhofer, E.2
Mugaragu, I.3
Sauer, H.U.4
Oswald, H.5
Fleck, E.6
-
10
-
-
0030216930
-
Binary reconstruction of the heart chambers from biplane angiographic image sequences
-
Prause, G. P. M.; D. G. W. Onnasch: Binary reconstruction of the heart chambers from biplane angiographic image sequences. IEEE Trans. Med. Imaging 15 (1996), 532-546.
-
(1996)
IEEE Trans. Med. Imaging
, vol.15
, pp. 532-546
-
-
Prause, G.P.M.1
Onnasch, D.G.W.2
-
11
-
-
0030417884
-
Geometrically correct 3D-reconstruction of coronary wall and plaque: Combining biplane angiography and intravascular ultrasound
-
Prause, G.; S. C. DeJong, C. R. McKay, M. Sonka: Geometrically correct 3D-reconstruction of coronary wall and plaque: combining biplane angiography and intravascular ultrasound. IEEE Comp. Cardiol. 23 (1996), 325-328.
-
(1996)
IEEE Comp. Cardiol.
, vol.23
, pp. 325-328
-
-
Prause, G.1
DeJong, S.C.2
McKay, C.R.3
Sonka, M.4
-
12
-
-
0031333797
-
ANGIO-LINK: On-line acquisition and assignment of gantry geometry data of biplane x-ray systems for analytic angiogram quantification in the cathlab
-
Fischer, F.; W. Wunderlich, D. Horstkotte, H.-P. Schultheiss: ANGIO-LINK: On-line acquisition and assignment of gantry geometry data of biplane x-ray systems for analytic angiogram quantification in the cathlab. IEEE Comp. Cardiol. 24 (1997), 533-536.
-
(1997)
IEEE Comp. Cardiol.
, vol.24
, pp. 533-536
-
-
Fischer, F.1
Wunderlich, W.2
Horstkotte, D.3
Schultheiss, H.-P.4
-
13
-
-
0024080148
-
Optical distortion due to geomagnetism in quantitative angiography
-
Solzbach, U.; U. Oser, H. Wollschläger, A. Zeiher, H. J. Just: Optical distortion due to geomagnetism in quantitative angiography. IEEE Comp. Cardiol. (1989), 355-357.
-
(1989)
IEEE Comp. Cardiol.
, pp. 355-357
-
-
Solzbach, U.1
Oser, U.2
Wollschläger, H.3
Zeiher, A.4
Just, H.J.5
-
14
-
-
84944007037
-
Geometric image correction and isocenter calibration at oblique biplane angiographic views
-
Onnasch, D. G. W.; G. P. M. Prause: Geometric image correction and isocenter calibration at oblique biplane angiographic views. IEEE Comp. Cardiol. (1992), 647-650.
-
(1992)
IEEE Comp. Cardiol.
, pp. 647-650
-
-
Onnasch, D.G.W.1
Prause, G.P.M.2
-
15
-
-
0027867206
-
Effect of spatial orientation on the image-intensifier distortion in quantitative coronary angiography
-
Gronenschild, E.: Effect of spatial orientation on the image-intensifier distortion in quantitative coronary angiography. IEEE Comp. Cardiol. (1993), 595-598.
-
(1993)
IEEE Comp. Cardiol.
, pp. 595-598
-
-
Gronenschild, E.1
-
16
-
-
0031333798
-
Inter- and extrapolation of correction coefficients in dynamic image rectification
-
Wahle, A.; U. Krauss, H. Oswald, E. Fleck: Inter- and extrapolation of correction coefficients in dynamic image rectification. IEEE Comp. Cardiol. 24 (1997), 521-524.
-
(1997)
IEEE Comp. Cardiol.
, vol.24
, pp. 521-524
-
-
Wahle, A.1
Krauss, U.2
Oswald, H.3
Fleck, E.4
-
17
-
-
0343149912
-
Validation of online 3D-localization using isocenter-based biplane radiography and instrumental rotational image alignment
-
Wunderlich, W.; F. Fischer, A. J. Morguet, H. R. Arntz, D. Horstkotte, H.-P. Schultheiss: Validation of online 3D-localization using isocenter-based biplane radiography and instrumental rotational image alignment IEEE Comp. Cardiol. 25 (1998), 433-436.
-
(1998)
IEEE Comp. Cardiol.
, vol.25
, pp. 433-436
-
-
Wunderlich, W.1
Fischer, F.2
Morguet, A.J.3
Arntz, H.R.4
Horstkotte, D.5
Schultheiss, H.-P.6
-
18
-
-
0023561960
-
Computed triple orthogonal projections for optimal radiological imaging with biplane isocentric x-ray systems
-
Wollschläger, H.; A. Zeiher, P. Lee, U. Solzbach, T. Bonzel, H. J. Just: Computed triple orthogonal projections for optimal radiological imaging with biplane isocentric x-ray systems. IEEE Comp. Cardiol. (1987), 185-188.
-
(1987)
IEEE Comp. Cardiol.
, pp. 185-188
-
-
Wollschläger, H.1
Zeiher, A.2
Lee, P.3
Solzbach, U.4
Bonzel, T.5
Just, H.J.6
-
19
-
-
0028200739
-
Optimum angiographie visualization of coronary segments using computer-aided 3D-reconstruction from biplane views
-
Solzbach, U.; U. Oser, M. Rombach, H. Wollschläger, H. J. Just: Optimum angiographie visualization of coronary segments using computer-aided 3D-reconstruction from biplane views. Comp. Biomed. Res. 27 (1994), 178-198.
-
(1994)
Comp. Biomed. Res.
, vol.27
, pp. 178-198
-
-
Solzbach, U.1
Oser, U.2
Rombach, M.3
Wollschläger, H.4
Just, H.J.5
-
20
-
-
0028397659
-
Determination of optimal angiographic viewing angles: Basic principles and evaluation study
-
Dumay, A. C. M.; J. H. C. Reiber, J. J. Gerbrands: Determination of optimal angiographic viewing angles: basic principles and evaluation study. IEEE Trans. Med. Imaging 13 (1994), 13-24. 884
-
(1994)
IEEE Trans. Med. Imaging
, vol.13
, pp. 13-24
-
-
Dumay, A.C.M.1
Reiber, J.H.C.2
Gerbrands, J.J.3
|