Volumn 23, Issue 9, 1999, Pages 98-106

Relative efficiencies of double filters or tighter filters for small- organism removals

Author keywords

[No Author keywords available]

Indexed keywords

BACTERIUM; CHANNEL GATING; FILTER; FILTRATION; FLOW RATE; MEMBRANE; NONHUMAN; POROSITY; REVIEW; TEMPERATURE; VISCOSITY;

EID: 0032872891     PISSN: 01478087     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (3)

References (19)
  • 2
    • 0030063809 scopus 로고    scopus 로고
    • Bacterial Retention Mechanisms of Membrane Filters
    • U. Osumi, N. Yamada, and U. Toya, "Bacterial Retention Mechanisms of Membrane Filters," PDA J. Pharm. Sci. Technol. 50 (1), 30-34 (1996).
    • (1996) PDA J. Pharm. Sci. Technol. , vol.50 , Issue.1 , pp. 30-34
    • Osumi, U.1    Yamada, N.2    Toya, U.3
  • 3
    • 0002235305 scopus 로고
    • Scanning Electron Microscopy of Nanobacteria - Novel Biofilm Producing Organisms in Blood
    • K.K. Akerman, I. Kuronen, and E.O. Kajander, "Scanning Electron Microscopy of Nanobacteria - Novel Biofilm Producing Organisms in Blood," Scanning 15, Suppl. III (1993).
    • (1993) Scanning , vol.15 , Issue.3 SUPPL.
    • Akerman, K.K.1    Kuronen, I.2    Kajander, E.O.3
  • 4
    • 0000899711 scopus 로고    scopus 로고
    • Fetal Bovine Serum: Discovery of Nanobacteria
    • E.O. Kajander, K. Kuronen, and N. Ciftcioglu, "Fetal Bovine Serum: Discovery of Nanobacteria," Mol. Biol. Cell 7 (Suppl.), 517a (1996).
    • (1996) Mol. Biol. Cell , vol.7 , Issue.SUPPL.
    • Kajander, E.O.1    Kuronen, K.2    Ciftcioglu, N.3
  • 5
    • 0007837065 scopus 로고
    • Paul Hargreaves Speaks Out on Pharmaceutical Manufacturing
    • P. Hargreaves, "Paul Hargreaves Speaks Out on Pharmaceutical Manufacturing," PDA Letter 29, 10-13 (1993).
    • (1993) PDA Letter , vol.29 , pp. 10-13
    • Hargreaves, P.1
  • 7
    • 0002344128 scopus 로고
    • Viable but Non-Culturable Bacteria and Their Implications for Water Purification
    • R.R. Colwell and A. Huq, "Viable but Non-Culturable Bacteria and Their Implications for Water Purification," Ultrapure Water 122 (3), 67-74 (1995).
    • (1995) Ultrapure Water , vol.122 , Issue.3 , pp. 67-74
    • Colwell, R.R.1    Huq, A.2
  • 8
    • 0032439728 scopus 로고    scopus 로고
    • Diminutive Bacteria -Implications for Sterile Filtration
    • P. Blosse, E. Boulter, and S. Sundaram, "Diminutive Bacteria -Implications for Sterile Filtration," Amer. Biotechnol. Lab. 16 (12), 38-40 (1998).
    • (1998) Amer. Biotechnol. Lab. , vol.16 , Issue.12 , pp. 38-40
    • Blosse, P.1    Boulter, E.2    Sundaram, S.3
  • 9
    • 85069240106 scopus 로고    scopus 로고
    • Application of Membrane Filtration for Removal of Diminutive Bioburden Organisms in Pharmaceutical Products and Processes
    • in press
    • S. Sundaram et al., "Application of Membrane Filtration for Removal of Diminutive Bioburden Organisms in Pharmaceutical Products and Processes," PDA J. Pharm. Sci. Technol, in press.
    • PDA J. Pharm. Sci. Technol
    • Sundaram, S.1
  • 10
    • 0031705375 scopus 로고    scopus 로고
    • Application-Directed Selection of 0.1-μm or 0.2-μm Rated Sterilizing Filters
    • T.H. Meltzer, M.W. Jornitz, and A.M. Trotter, "Application-Directed Selection of 0.1-μm or 0.2-μm Rated Sterilizing Filters," Pharm. Technol. 22 (9), 116-122 (1998).
    • (1998) Pharm. Technol. , vol.22 , Issue.9 , pp. 116-122
    • Meltzer, T.H.1    Jornitz, M.W.2    Trotter, A.M.3
  • 11
    • 0005463070 scopus 로고    scopus 로고
    • Sterile Double Filtration
    • M.W. Jornitz and T.H. Meltzer, "Sterile Double Filtration," Pharm. Technol. 22 (10), 92-100 (1998).
    • (1998) Pharm. Technol. , vol.22 , Issue.10 , pp. 92-100
    • Jornitz, M.W.1    Meltzer, T.H.2
  • 12
    • 0000632290 scopus 로고
    • Aerosol Filters: Pore-Size Distribution in Fibrous Filters
    • H.W. Piekaar and L.A. Klarenburg, "Aerosol Filters: Pore-Size Distribution in Fibrous Filters," Chem. Eng. Sci. 22, 1399-1408 (1967).
    • (1967) Chem. Eng. Sci. , vol.22 , pp. 1399-1408
    • Piekaar, H.W.1    Klarenburg, L.A.2
  • 13
    • 0003220445 scopus 로고
    • Bacteria Removal Prediction in Membrane Filters
    • University of Tennessee, Knoxville
    • D.B. Pall and E.A. Kirnbauer, "Bacteria Removal Prediction in Membrane Filters," presented at 52nd Colloids and Surfaces Symposium, University of Tennessee, Knoxville, 1978.
    • (1978) 52nd Colloids and Surfaces Symposium
    • Pall, D.B.1    Kirnbauer, E.A.2
  • 14
    • 0042118639 scopus 로고
    • publication FTAS/TR Cleveland: Case Western Reserve University, Dept. of Mechanical and Aerospace Engineering
    • N.D. Rosenstein, A. Dybbs, and R.V. Edwards, "Nonlinear Flow in a Porous Medium," publication FTAS/TR (Cleveland: Case Western Reserve University, Dept. of Mechanical and Aerospace Engineering, 1980).
    • (1980) Nonlinear Flow in a Porous Medium
    • Rosenstein, N.D.1    Dybbs, A.2    Edwards, R.V.3
  • 18
    • 0031893594 scopus 로고    scopus 로고
    • Bacterial Cell Size and Surface Charge Characteristics Relevant to Filter Validation Studies
    • M.W. Mittelman, M.W. Jornitz, and T.H. Meltzer, "Bacterial Cell Size and Surface Charge Characteristics Relevant to Filter Validation Studies," PDA J. Pharm. Sci. Technol. 50 (1), 37-42 (1998).
    • (1998) PDA J. Pharm. Sci. Technol. , vol.50 , Issue.1 , pp. 37-42
    • Mittelman, M.W.1    Jornitz, M.W.2    Meltzer, T.H.3
  • 19
    • 7844234697 scopus 로고
    • Filtrative Particle Removal from Liquids
    • Marcel Dekker, New York
    • T.H. Meltzer, "Filtrative Particle Removal from Liquids," in Filtration in the Pharmaceutical Industry (Marcel Dekker, New York, 1986), pp. 343-346.
    • (1986) Filtration in the Pharmaceutical Industry , pp. 343-346
    • Meltzer, T.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.