메뉴 건너뛰기




Volumn 23, Issue 8, 1999, Pages 774-779

Feasibility of a tiny Gyro centrifugal pump as an implantable ventricular assist device

Author keywords

Hemolysis; Implantable; Infant; Pediatric; Small centrifugal pump; Ventricular assist device

Indexed keywords

CENTRIFUGAL PUMPS; CENTRIFUGATION; GYROSCOPES; HOUSING; IMPELLERS; LEFT VENTRICULAR ASSIST DEVICES; PEDIATRICS;

EID: 0032864444     PISSN: 0160564X     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1525-1594.1999.06421.x     Document Type: Article
Times cited : (12)

References (13)
  • 1
    • 0029759211 scopus 로고
    • Hemolytic characteristics of a pivot bearing supported Gyro centrifugal pump (C1E3) simulating various clinical applications
    • Takami Y, Makinouchi K, Nakazawa T, Benkowski R, Glueck J, Ohara Y, Nosé Y. Hemolytic characteristics of a pivot bearing supported Gyro centrifugal pump (C1E3) simulating various clinical applications. Artif Organs 1993;17:1042-9.
    • (1993) Artif Organs , vol.17 , pp. 1042-1049
    • Takami, Y.1    Makinouchi, K.2    Nakazawa, T.3    Benkowski, R.4    Glueck, J.5    Ohara, Y.6    Nosé, Y.7
  • 2
    • 0028852325 scopus 로고
    • HeartMate implantable left ventricular assist device: Bridge to transplantation and future applications
    • McCarthy PM. HeartMate implantable left ventricular assist device: bridge to transplantation and future applications. Ann Thorac Surg 1995;59:546-51.
    • (1995) Ann Thorac Surg , vol.59 , pp. 546-551
    • McCarthy, P.M.1
  • 5
    • 0030939380 scopus 로고    scopus 로고
    • Clinical experience with the MEDOS HIA-VAD system in infants and children: A preliminary report
    • Konertz W, Hotz H, Schneider M, Redlin M, Reul H. Clinical experience with the MEDOS HIA-VAD system in infants and children: A preliminary report. Ann Thorac Surg 1997; 63:1138-44.
    • (1997) Ann Thorac Surg , vol.63 , pp. 1138-1144
    • Konertz, W.1    Hotz, H.2    Schneider, M.3    Redlin, M.4    Reul, H.5
  • 13
    • 0026539951 scopus 로고
    • Effect of stationary guiding vanes on improvement of the washout behind the rotor in centrifugal blood pumps
    • Schima H, Huber L, Melvin D, Trubel W, Prodinger A, Losert U, Thoma H, Wolner E. Effect of stationary guiding vanes on improvement of the washout behind the rotor in centrifugal blood pumps. ASAIO J 1992;38:M220-4.
    • (1992) ASAIO J , vol.38
    • Schima, H.1    Huber, L.2    Melvin, D.3    Trubel, W.4    Prodinger, A.5    Losert, U.6    Thoma, H.7    Wolner, E.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.