메뉴 건너뛰기




Volumn 173, Issue 4, 1999, Pages 1017-1021

Resource requirements for interventional radiologic management of long- term ambulatory hemodialysis patients

Author keywords

[No Author keywords available]

Indexed keywords

AMBULATORY CARE; ARTICLE; FEMALE; HEALTH CARE QUALITY; HEALTH SERVICE; HEMODIALYSIS PATIENT; HUMAN; INTERVENTIONAL RADIOLOGY; MAJOR CLINICAL STUDY; MALE; MEDICAL RECORD; PRIORITY JOURNAL; RESOURCE MANAGEMENT;

EID: 0032861949     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/ajr.173.4.10511170     Document Type: Article
Times cited : (3)

References (10)
  • 1
    • 0003443751 scopus 로고    scopus 로고
    • New York: National Kidney Foundation
    • National Kidney Foundation Dialysis Outcomes Quality Initiative. Clinical practice guidelines for vascular access. New York: National Kidney Foundation, 1997:20, 22, 26, 55-59
    • (1997) Clinical Practice Guidelines for Vascular Access , pp. 20
  • 2
    • 0017350395 scopus 로고
    • Nine years' experience with internal arteriovenous fistulas for hemodialysis: Study of some factors influencing results
    • Kinnaert P, Vereerstraeten P, Toussaint C, Van Geertruyden J. Nine years' experience with internal arteriovenous fistulas for hemodialysis: study of some factors influencing results. BrJ Surg 1977;64:242-246
    • (1977) BrJ Surg , vol.64 , pp. 242-246
    • Kinnaert, P.1    Vereerstraeten, P.2    Toussaint, C.3    Van Geertruyden, J.4
  • 3
    • 0022452121 scopus 로고
    • Comparison of autogenous fistula versus expanded polytetrafluoroethylene graft fistula for angioaccess in hemodialysis
    • Kherlakian GM, Roedersheimer LR, Arbaugh JJ, Newmark KJ, King LR. Comparison of autogenous fistula versus expanded polytetrafluoroethylene graft fistula for angioaccess in hemodialysis. Am J Surg 1986;152:238-243
    • (1986) Am J Surg , vol.152 , pp. 238-243
    • Kherlakian, G.M.1    Roedersheimer, L.R.2    Arbaugh, J.J.3    Newmark, K.J.4    King, L.R.5
  • 6
    • 0029787793 scopus 로고    scopus 로고
    • Silastic cuffed catheters for hemodialysis vascular access: Thrombolytic and mechanical correction of malfunction
    • Suchoki PV, Conlon PJ Jr, Knelson MH, Harland R, Schwab SJ. Silastic cuffed catheters for hemodialysis vascular access: thrombolytic and mechanical correction of malfunction. Am J Kidney Dis 1996;28:379-386
    • (1996) Am J Kidney Dis , vol.28 , pp. 379-386
    • Suchoki, P.V.1    Conlon P.J., Jr.2    Knelson, M.H.3    Harland, R.4    Schwab, S.J.5
  • 7
    • 0030832873 scopus 로고    scopus 로고
    • Percutaneous intervention for permanent hemodialysis access: A review
    • Gray RJ. Percutaneous intervention for permanent hemodialysis access: a review. J Vasc Interv Radiol 1997;8:313-327
    • (1997) J Vasc Interv Radiol , vol.8 , pp. 313-327
    • Gray, R.J.1
  • 8
    • 0027299267 scopus 로고
    • Permanent vascular access: A nephrologist's view
    • Windus DW. Permanent vascular access: a nephrologist's view. Am J Kidney Dis 1993;21:457-471
    • (1993) Am J Kidney Dis , vol.21 , pp. 457-471
    • Windus, D.W.1
  • 9
    • 0030077086 scopus 로고    scopus 로고
    • Radiological placement of long-term hemodialysis catheters: The trend continues
    • Mauro MA, Jaques PF. Radiological placement of long-term hemodialysis catheters: the trend continues (editorial). Radiology 1996;198:316-317
    • (1996) Radiology , vol.198 , pp. 316-317
    • Mauro, M.A.1    Jaques, P.F.2
  • 10
    • 0345460370 scopus 로고    scopus 로고
    • Maintenance of long-term dialysis catheters
    • Jaques PF. Maintenance of long-term dialysis catheters. Tech Vasc Interv Radiol 1998;1:148-153
    • (1998) Tech Vasc Interv Radiol , vol.1 , pp. 148-153
    • Jaques, P.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.