Estimation of alveolar deadspace fraction using arterial and end-tidal CP2: A factor analysis using a physiological simulation

Author keywords

Lung: pulmonary deadspace, physiological ventilation, theoretical model

Indexed keywords

ARTERIAL CARBON DIOXIDE TENSION; ARTICLE; ARTIFICIAL VENTILATION; DIAGNOSTIC ACCURACY; END TIDAL CARBON DIOXIDE TENSION; FACTORIAL ANALYSIS; LUNG ALVEOLUS; LUNG ARTERIOVENOUS SHUNT; LUNG DEAD SPACE; LUNG DISEASE; LUNG MINUTE VOLUME; LUNG VENTILATION; METABOLIC RATE; PATIENT MONITORING; PREDICTION; SIMULATION; WEANING;

EID: 0032857060     PISSN: 0310057X     EISSN: None     Source Type: Journal    
DOI: 10.1177/0310057x9902700503     Document Type: Article
Times cited : (41)

References (26)
  • 1
    • 0022609241 scopus 로고
    • The physiologic determinants of ventilator dependence
    • Marini JJ. The physiologic determinants of ventilator dependence. Resp Care 1986; 31:271-282.
    • (1986) Resp Care , vol.31 , pp. 271-282
    • Marini, J.J.1
  • 2
    • 0025022632 scopus 로고
    • Work of breathing: Reliable predictor of weaning and extubation
    • Shikora SA, Bistrian BR, Borlase BC, et al. Work of breathing: reliable predictor of weaning and extubation. Crit Care Med 1990; 18:157-162.
    • (1990) Crit Care Med , vol.18 , pp. 157-162
    • Shikora, S.A.1    Bistrian, B.R.2    Borlase, B.C.3
  • 4
    • 0029098479 scopus 로고
    • Intraoperative end-tidal carbon dioxide values and derived calculations correlated with outcome: Prognosis and capnography
    • Domsky M, Wilson RF, Heins J. Intraoperative end-tidal carbon dioxide values and derived calculations correlated with outcome: Prognosis and capnography. Crit Care Med 1995; 23:1497-1503.
    • (1995) Crit Care Med , vol.23 , pp. 1497-1503
    • Domsky, M.1    Wilson, R.F.2    Heins, J.3
  • 6
    • 72849165961 scopus 로고
    • 2 tension difference in anaesthetized man
    • 2 tension difference in anaesthetized man. J App Physiol 1960; 15:383-389.
    • (1960) J App Physiol , vol.15 , pp. 383-389
    • Nunn, J.F.1    Hill, D.W.2
  • 7
    • 0031671408 scopus 로고    scopus 로고
    • A physiology simulator: Validation of its respiratory components and its ability to predict the patient's response to changes in mechanical ventilation
    • Hardman JG, Bedforth NM, Ahmed AB, Mahajan RP, Aitkenhead AR. A physiology simulator: validation of its respiratory components and its ability to predict the patient's response to changes in mechanical ventilation. Br J Anaesth 1998; 81:327-332.
    • (1998) Br J Anaesth , vol.81 , pp. 327-332
    • Hardman, J.G.1    Bedforth, N.M.2    Ahmed, A.B.3    Mahajan, R.P.4    Aitkenhead, A.R.5
  • 8
    • 0031918393 scopus 로고    scopus 로고
    • Predicting the response to adjustment of mechanical ventilation using a physiological simulator
    • Hardman JG, Bedforth NM, Mahajan RP, Aitkenhead AR. Predicting the response to adjustment of mechanical ventilation using a physiological simulator. Br J Anaesth 1998; 80:549.
    • (1998) Br J Anaesth , vol.80 , pp. 549
    • Hardman, J.G.1    Bedforth, N.M.2    Mahajan, R.P.3    Aitkenhead, A.R.4
  • 9
    • 0033064564 scopus 로고    scopus 로고
    • Estimating venous admixture using a physiological simulator
    • Hardman JG, Bedforth NM. Estimating venous admixture using a physiological simulator. Br J Anaesth 1998; 82:346-349.
    • (1998) Br J Anaesth , vol.82 , pp. 346-349
    • Hardman, J.G.1    Bedforth, N.M.2
  • 10
    • 0342783870 scopus 로고    scopus 로고
    • Predicting the patient's response to changes in mechanical ventilation: A comparison between physicians and a physiological simulator
    • Bedforth NM, Hardman JG, Mahajan RP, Aitkenhead AR. Predicting the patient's response to changes in mechanical ventilation: a comparison between physicians and a physiological simulator. Br J Anaesth 1998; 80:161-162.
    • (1998) Br J Anaesth , vol.80 , pp. 161-162
    • Bedforth, N.M.1    Hardman, J.G.2    Mahajan, R.P.3    Aitkenhead, A.R.4
  • 12
    • 0019382061 scopus 로고
    • A computer program for calculating respiratory anatomic deadspace
    • Rickaby DA, Hanus MJ, Hamilton LH. A computer program for calculating respiratory anatomic deadspace. Int J Biomed Comput 1981; 12:125-138.
    • (1981) Int J Biomed Comput , vol.12 , pp. 125-138
    • Rickaby, D.A.1    Hanus, M.J.2    Hamilton, L.H.3
  • 14
    • 0022492073 scopus 로고
    • Gas exchange during controlled ventilation in children with normal and abnormal pulmonary circulation: A study using the single breath test for carbon dioxide
    • Fletcher R, Niklason L, Drefeldt B. Gas exchange during controlled ventilation in children with normal and abnormal pulmonary circulation: A study using the single breath test for carbon dioxide. Anesth Analg 1986; 65:645-652.
    • (1986) Anesth Analg , vol.65 , pp. 645-652
    • Fletcher, R.1    Niklason, L.2    Drefeldt, B.3
  • 15
    • 0019454371 scopus 로고
    • Prediction of the physiological deadspace/tidal volume ratio during anaesthesia/IPPV from simple pre-operative tests
    • Fletcher R, Jonson B. Prediction of the physiological deadspace/tidal volume ratio during anaesthesia/IPPV from simple pre-operative tests. Acta Anaesthesiol Scand 1981; 25:58-62.
    • (1981) Acta Anaesthesiol Scand , vol.25 , pp. 58-62
    • Fletcher, R.1    Jonson, B.2
  • 16
    • 0017181176 scopus 로고
    • Gas exchange during exercise in healthy people. 1. The physiological deadspace volume
    • Bradley CA, Harris EA, Seelye ER, Whitlock RM. Gas exchange during exercise in healthy people. 1. The physiological deadspace volume. Clin Sci Molec Med 1976; 51:323-333.
    • (1976) Clin Sci Molec Med , vol.51 , pp. 323-333
    • Bradley, C.A.1    Harris, E.A.2    Seelye, E.R.3    Whitlock, R.M.4
  • 17
    • 0025989556 scopus 로고
    • Measurement of alveolar ventilation and changes in deadspace by indirect calorimetry during mechanical ventilation: A laboratory and clinical validation
    • Kiiski R, Takala J, Eissa NT. Measurement of alveolar ventilation and changes in deadspace by indirect calorimetry during mechanical ventilation: A laboratory and clinical validation. Crit Care Med 1991; 19:1303-1309.
    • (1991) Crit Care Med , vol.19 , pp. 1303-1309
    • Kiiski, R.1    Takala, J.2    Eissa, N.T.3
  • 18
    • 0024401336 scopus 로고
    • A microcomputer system for on-line monitoring of pulmonary function during artificial ventilation
    • Klingstedt C, Ludwigs U, Baehrendtz S, Bokliden A, Matell G. A microcomputer system for on-line monitoring of pulmonary function during artificial ventilation. Int J Clin Monit Comput 1989; 6:99-107.
    • (1989) Int J Clin Monit Comput , vol.6 , pp. 99-107
    • Klingstedt, C.1    Ludwigs, U.2    Baehrendtz, S.3    Bokliden, A.4    Matell, G.5
  • 19
    • 0026718089 scopus 로고
    • Ventilation/perfusion indices do not correlate with the difference between oxygen consumption measured by the fick principle and metabolic monitoring systems in critically ill patients
    • Myburgh JA, Webb RK, Worthley LIG. Ventilation/perfusion indices do not correlate with the difference between oxygen consumption measured by the Fick principle and metabolic monitoring systems in critically ill patients. Crit Care Med 1992; 20:479-482.
    • (1992) Crit Care Med , vol.20 , pp. 479-482
    • Myburgh, J.A.1    Webb, R.K.2    Worthley, L.I.G.3
  • 20
    • 0028624696 scopus 로고
    • The effect of a heat and moisture exchange filter on sidestream spirometry in critically ill patients
    • Puolakka JJ, Jousela IT. The effect of a heat and moisture exchange filter on sidestream spirometry in critically ill patients. Int J Clin Monit Comput 1994; 11:217-222.
    • (1994) Int J Clin Monit Comput , vol.11 , pp. 217-222
    • Puolakka, J.J.1    Jousela, I.T.2
  • 21
    • 0027340719 scopus 로고
    • Breathing system filters can affect the performance of anaesthetic monitors
    • Costigan SN, Snowdon SL. Breathing system filters can affect the performance of anaesthetic monitors. Anaesthesia 1993; 48:1015-1016.
    • (1993) Anaesthesia , vol.48 , pp. 1015-1016
    • Costigan, S.N.1    Snowdon, S.L.2
  • 22
    • 0023908393 scopus 로고
    • Invasive and non-invasive measurement of the respiratory deadspace in anaesthetized children with cardiac disease
    • Fletcher R. Invasive and non-invasive measurement of the respiratory deadspace in anaesthetized children with cardiac disease. Anesth Analg 1988; 67:442-447.
    • (1988) Anesth Analg , vol.67 , pp. 442-447
    • Fletcher, R.1
  • 23
    • 0024571805 scopus 로고
    • Relationship between alveolar deadspace and arterial oxygenation in children with congenital cardiac disease
    • Fletcher R. Relationship between alveolar deadspace and arterial oxygenation in children with congenital cardiac disease. Br J Anaesth 1989; 62:168-176.
    • (1989) Br J Anaesth , vol.62 , pp. 168-176
    • Fletcher, R.1
  • 24
    • 0025580066 scopus 로고
    • Deadspace during anaesthesia
    • Fletcher R. Deadspace during anaesthesia. Acta Anaesthesiol Scand 1990; 34:46-50.
    • (1990) Acta Anaesthesiol Scand , vol.34 , pp. 46-50
    • Fletcher, R.1
  • 25
    • 0015888103 scopus 로고
    • The use of iso-shunt lines for control of oxygen therapy
    • Benatar SR, Hewlett AM, Nunn JF. The use of iso-shunt lines for control of oxygen therapy. Br J Anaesth 1973; 45:711-718.
    • (1973) Br J Anaesth , vol.45 , pp. 711-718
    • Benatar, S.R.1    Hewlett, A.M.2    Nunn, J.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.