메뉴 건너뛰기




Volumn 9, Issue 9, 1999, Pages 853-858

Toward real-world sequencing by microdevice electrophoresis

Author keywords

[No Author keywords available]

Indexed keywords

ALCOHOL; DNA FRAGMENT;

EID: 0032856328     PISSN: 10889051     EISSN: None     Source Type: Journal    
DOI: 10.1101/gr.9.9.853     Document Type: Article
Times cited : (60)

References (20)
  • 1
    • 0028536034 scopus 로고
    • Separation of fragments up to 570 bases in length by use of 6% T non-crosslinked polyacrylamide for DNA sequencing in capillary electrophoresis
    • Best, N., E. Arriaga, D.Y. Chen, and N.J. Dovichi. 1994. Separation of fragments up to 570 bases in length by use of 6% T non-crosslinked polyacrylamide for DNA sequencing in capillary electrophoresis. Anal. Chem. 66: 4063-4067.
    • (1994) Anal. Chem. , vol.66 , pp. 4063-4067
    • Best, N.1    Arriaga, E.2    Chen, D.Y.3    Dovichi, N.J.4
  • 2
    • 0029830767 scopus 로고    scopus 로고
    • Rapid DNA sequencing of more than 1000 bases per run by capillary electrophoresis using replaceable linear polyacrylamide solutions
    • Carrilho, E. M.C. Ruiz-Martinez, J. Berka, I. Smirnov, W. Goetzinger, A.W. Miller, D. Brady, and B.L. Karger. 1996. Rapid DNA sequencing of more than 1000 bases per run by capillary electrophoresis using replaceable linear polyacrylamide solutions Anal. Chem. 68: 3305-3313.
    • (1996) Anal. Chem. , vol.68 , pp. 3305-3313
    • Carrilho, E.1    Ruiz-Martinez, M.C.2    Berka, J.3    Smirnov, I.4    Goetzinger, W.5    Miller, A.W.6    Brady, D.7    Karger, B.L.8
  • 3
    • 0031978181 scopus 로고    scopus 로고
    • Base-calling of automated sequencer traces using Phred. II. Error probabilities
    • Ewing, B. and P. Green. 1998. Base-calling of automated sequencer traces using Phred. II. Error probabilities. Genome Res. 8: 186-194.
    • (1998) Genome Res. , vol.8 , pp. 186-194
    • Ewing, B.1    Green, P.2
  • 4
    • 0031955518 scopus 로고    scopus 로고
    • Base-calling of automated sequencer traces using Phred. I. Accuracy assessment
    • Ewing, B., LD. Hillier, M.C. Wendl, and P. Green. 1998. Base-calling of automated sequencer traces using Phred. I. Accuracy assessment. Genome Res. 8: 175-185.
    • (1998) Genome Res. , vol.8 , pp. 175-185
    • Ewing, B.1    Hillier, L.D.2    Wendl, M.C.3    Green, P.4
  • 5
    • 77956015605 scopus 로고    scopus 로고
    • Downsizing chemistry. Chemical analysis and synthesis on microchips promise a variety of potential benefits
    • Freemantle, M. 1999. Downsizing chemistry. Chemical analysis and synthesis on microchips promise a variety of potential benefits. Chem. Eng. News 77: 27-36.
    • (1999) Chem. Eng. News , vol.77 , pp. 27-36
    • Freemantle, M.1
  • 6
    • 0031913461 scopus 로고    scopus 로고
    • Characterization of high molecular weight mass linear polyacrylamide powder prepared by emulsion polymerization as a replaceable polymer matrix for DNA sequencing by capillary electrophoresis
    • Goetzinger, W., L. Kotler, E. Carrilho, M.C. Ruiz-Martinez, O. Salas-Solano, and B.L. Karger. 1998. Characterization of high molecular weight mass linear polyacrylamide powder prepared by emulsion polymerization as a replaceable polymer matrix for DNA sequencing by capillary electrophoresis. Electrophoresis 19: 242-248.
    • (1998) Electrophoresis , vol.19 , pp. 242-248
    • Goetzinger, W.1    Kotler, L.2    Carrilho, E.3    Ruiz-Martinez, M.C.4    Salas-Solano, O.5    Karger, B.L.6
  • 7
    • 0342507903 scopus 로고
    • Micromachining a miniaturized capillary electrophoresis-based chemical analysis system on a chip
    • Harrison, D.J., K. Fluri, K. Seiler, Z. Fan, C.S. Effenhauser, and A. Manz. 1993. Micromachining a miniaturized capillary electrophoresis-based chemical analysis system on a chip. Science 261: 895-897.
    • (1993) Science , vol.261 , pp. 895-897
    • Harrison, D.J.1    Fluri, K.2    Seiler, K.3    Fan, Z.4    Effenhauser, C.S.5    Manz, A.6
  • 8
    • 46549101119 scopus 로고
    • High-performance electrophoresis elimination of electroendosmosis and solute adsorption
    • Hjerten, S. 1985. High-performance electrophoresis elimination of electroendosmosis and solute adsorption. J. Chromatogr. 347: 191-198.
    • (1985) J. Chromatogr. , vol.347 , pp. 191-198
    • Hjerten, S.1
  • 9
    • 33845279783 scopus 로고
    • Bias in quantitative capillary zone electrophoresis caused by electrokinetic sample injection
    • Huang, X., M.J. Gordon, and R.N. Zare. 1988. Bias in quantitative capillary zone electrophoresis caused by electrokinetic sample injection. Anal. Chem. 60: 375-377.
    • (1988) Anal. Chem. , vol.60 , pp. 375-377
    • Huang, X.1    Gordon, M.J.2    Zare, R.N.3
  • 10
    • 0029692711 scopus 로고    scopus 로고
    • Microchip electrophoretic immunoassay for serum cortisol
    • Koutny, L.B., D. Schmalzing, T.A. Taylor, and M. Fuchs. 1996. Microchip electrophoretic immunoassay for serum cortisol. Anal. Chem. 68: 18-22.
    • (1996) Anal. Chem. , vol.68 , pp. 18-22
    • Koutny, L.B.1    Schmalzing, D.2    Taylor, T.A.3    Fuchs, M.4
  • 12
    • 0033083477 scopus 로고    scopus 로고
    • Optimization of high-speed DNA sequencing on microfabricated capillary electrophoresis channels
    • Liu, S., Y. Shi, W.W. Ja, and R.A. Mathies. 1999. Optimization of high-speed DNA sequencing on microfabricated capillary electrophoresis channels. Anal. Chem. 71: 566-573.
    • (1999) Anal. Chem. , vol.71 , pp. 566-573
    • Liu, S.1    Shi, Y.2    Ja, W.W.3    Mathies, R.A.4
  • 13
    • 0000990701 scopus 로고
    • Analysis of resolution in DNA sequencing by capillary gel electrophoresis
    • Luckey, J.A., T.B. Norris, and L.M. Smith, 1993. Analysis of resolution in DNA sequencing by capillary gel electrophoresis. J Phys. Chem. 97: 3067-3075.
    • (1993) J Phys. Chem. , vol.97 , pp. 3067-3075
    • Luckey, J.A.1    Norris, T.B.2    Smith, L.M.3
  • 14
    • 0032049675 scopus 로고    scopus 로고
    • A sample purification method for rugged and high-performance DNA sequencing by capillary electrophoresis using replaceable polymer solutions. A. Development of the cleanup protocol
    • Ruiz-Martinez, M.C., O. Salas-Solano, E. Carrilho, L. Kotler, and B.L. Karger. 1998. A sample purification method for rugged and high-performance DNA sequencing by capillary electrophoresis using replaceable polymer solutions. A. Development of the cleanup protocol. Anal. Chem. 70: 1516-1527.
    • (1998) Anal. Chem. , vol.70 , pp. 1516-1527
    • Ruiz-Martinez, M.C.1    Salas-Solano, O.2    Carrilho, E.3    Kotler, L.4    Karger, B.L.5
  • 15
    • 0032047581 scopus 로고    scopus 로고
    • A sample purification method for rugged and high-performance DNA sequencing using replaceable polymer solutions. B. Quantitative determination of the role of sample matrix components on sequencing analysis
    • Salas-Solano, O., M.C. Ruiz-Martinez, E. Carrilho, L. Kotler, and B.L. Karger. 1998. A sample purification method for rugged and high-performance DNA sequencing using replaceable polymer solutions. B. Quantitative determination of the role of sample matrix components on sequencing analysis. Anal. Chem. 70: 1528-1535.
    • (1998) Anal. Chem. , vol.70 , pp. 1528-1535
    • Salas-Solano, O.1    Ruiz-Martinez, M.C.2    Carrilho, E.3    Kotler, L.4    Karger, B.L.5
  • 18
    • 0033562563 scopus 로고    scopus 로고
    • Two-color multiplexed analysis of eight short tandem repeat loci with an electrophoretic microdevice
    • Schmalzing, D., L.B. Koutny, A. Adourian, D. Chisholm, P. Matsudaira, and D. Ehrlich. 1999. Two-color multiplexed analysis of eight short tandem repeat loci with an electrophoretic microdevice. Anal. Biochem. 270: 148-152.
    • (1999) Anal. Biochem. , vol.270 , pp. 148-152
    • Schmalzing, D.1    Koutny, L.B.2    Adourian, A.3    Chisholm, D.4    Matsudaira, P.5    Ehrlich, D.6
  • 20
    • 0029645606 scopus 로고
    • Ultra-high-speed DNA sequencing using capillary electrophoresis chips
    • Woolley, A.T. and R.A. Mathies. 1995. Ultra-high-speed DNA sequencing using capillary electrophoresis chips. Anal. Chem. 67: 3676-3680.
    • (1995) Anal. Chem. , vol.67 , pp. 3676-3680
    • Woolley, A.T.1    Mathies, R.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.