메뉴 건너뛰기




Volumn 364, Issue , 1999, Pages 254-266

Use of a polyglycolide lactide cement plug restrictor in total hip arthroplasty

Author keywords

[No Author keywords available]

Indexed keywords

BONE CEMENT; POLYETHYLENE; POLYGLACTIN;

EID: 0032855454     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1097/00003086-199907000-00032     Document Type: Article
Times cited : (17)

References (29)
  • 1
    • 0040500608 scopus 로고
    • Force plate analysis: A noninvasive tool for gait evaluation
    • Anderson MA, Mann FA: Force plate analysis: A noninvasive tool for gait evaluation. Small Anim Orthop 16:857-861, 1994.
    • (1994) Small Anim Orthop , vol.16 , pp. 857-861
    • Anderson, M.A.1    Mann, F.A.2
  • 2
    • 0021192353 scopus 로고
    • Effect of cement pressure and bone strength on polymethylmethacrylate fixation
    • Askew MJ, Steege JW, Lewis JL, Ranieri JR, Wixson RL: Effect of cement pressure and bone strength on polymethylmethacrylate fixation. J Orthop Res 1:412-420, 1984.
    • (1984) J Orthop Res , vol.1 , pp. 412-420
    • Askew, M.J.1    Steege, J.W.2    Lewis, J.L.3    Ranieri, J.R.4    Wixson, R.L.5
  • 3
    • 58149372230 scopus 로고
    • Degradable implant materials: A review of synthetic absorbable polymers and their applications
    • Barrows TH: Degradable implant materials: A review of synthetic absorbable polymers and their applications. Clin Mater 1:223-257, 1986.
    • (1986) Clin Mater , vol.1 , pp. 223-257
    • Barrows, T.H.1
  • 4
    • 0025971712 scopus 로고
    • Current concepts review: Adsorbable implants for the fixation of fractures
    • Bostman O: Current concepts review: Adsorbable implants for the fixation of fractures. J Bone Joint Surg 73A:148-153, 1991.
    • (1991) J Bone Joint Surg , vol.73 A , pp. 148-153
    • Bostman, O.1
  • 5
    • 0025784686 scopus 로고
    • Osteolytic changes accompanying degradation of absorbable fracture fixation implants
    • Bostman O: Osteolytic changes accompanying degradation of absorbable fracture fixation implants. J Bone Joint Surg 73B:679-682, 1991.
    • (1991) J Bone Joint Surg , vol.73 B , pp. 679-682
    • Bostman, O.1
  • 6
    • 0025334647 scopus 로고
    • Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers
    • Bostman O, Hirvensalo E, Makinen J, Rokkanen P: Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers. J Bone Joint Surg 72B:592-595, 1990.
    • (1990) J Bone Joint Surg , vol.72 B , pp. 592-595
    • Bostman, O.1    Hirvensalo, E.2    Makinen, J.3    Rokkanen, P.4
  • 7
    • 0025255649 scopus 로고
    • Degradable polyglycolide rods for the internal fixation of displaced bimalleolar fractures
    • Bostman O, Hirvensalo E, Vainionpaa S, et al: Degradable polyglycolide rods for the internal fixation of displaced bimalleolar fractures. Int Orthop 14:1-8, 1990.
    • (1990) Int Orthop , vol.14 , pp. 1-8
    • Bostman, O.1    Hirvensalo, E.2    Vainionpaa, S.3
  • 9
    • 0023198604 scopus 로고
    • Biodegradable internal fixation for malleolar fractures: A prospective randomised trial
    • Bostman O, Vaninionpaa S, Hirvensalo E, et al: Biodegradable internal fixation for malleolar fractures: A prospective randomised trial. J Bone Joint Surg 69B:615-619, 1987.
    • (1987) J Bone Joint Surg , vol.69 B , pp. 615-619
    • Bostman, O.1    Vaninionpaa, S.2    Hirvensalo, E.3
  • 10
    • 0021355275 scopus 로고
    • Femoral cement pressurization during total hip arthroplasty
    • Bourne RB, Oh I, Harris WH: Femoral cement pressurization during total hip arthroplasty. Clin Orthop 183:12-16, 1984.
    • (1984) Clin Orthop , vol.183 , pp. 12-16
    • Bourne, R.B.1    Oh, I.2    Harris, W.H.3
  • 11
    • 0015754154 scopus 로고
    • Ectopic ossification following total hip replacement. Incidence and method of classification
    • Brooker AF, Bowerman JW, Robinson RA, Riley LH: Ectopic ossification following total hip replacement. Incidence and method of classification. J Bone Joint Surg 55A:1629-1632, 1973.
    • (1973) J Bone Joint Surg , vol.55 A , pp. 1629-1632
    • Brooker, A.F.1    Bowerman, J.W.2    Robinson, R.A.3    Riley, L.H.4
  • 13
    • 0028054956 scopus 로고
    • Wear and corrosion of modular interfaces in total hip replacements
    • Cook SD, Barrack RL, Baffes GC, et al: Wear and corrosion of modular interfaces in total hip replacements. Clin Orthop 298:80-88, 1994.
    • (1994) Clin Orthop , vol.298 , pp. 80-88
    • Cook, S.D.1    Barrack, R.L.2    Baffes, G.C.3
  • 14
    • 0027717246 scopus 로고
    • In vitro and in vivo studies of pressurization of femoral cement in total hip arthroplasty
    • Davies JP, Harris WH: In vitro and in vivo studies of pressurization of femoral cement in total hip arthroplasty. J Arthroplasty 8:585-591, 1983.
    • (1983) J Arthroplasty , vol.8 , pp. 585-591
    • Davies, J.P.1    Harris, W.H.2
  • 15
    • 0026465553 scopus 로고
    • Osteolysis after biodegradable pin fixation of fractures in children
    • Fraser RK, Cole WG: Osteolysis after biodegradable pin fixation of fractures in children. J Bone Joint Surg 74B:929-930, 1992.
    • (1992) J Bone Joint Surg , vol.74 B , pp. 929-930
    • Fraser, R.K.1    Cole, W.G.2
  • 16
    • 0026450611 scopus 로고
    • Advances in biomaterials and factors affecting implant fixation
    • The American Academy of Orthopaedic Surgeons
    • Friedman RJ: Advances in biomaterials and factors affecting implant fixation. The American Academy of Orthopaedic Surgeons, Inst Course Lect 41:127-136, 1992.
    • (1992) Inst Course Lect , vol.41 , pp. 127-136
    • Friedman, R.J.1
  • 18
    • 0018687995 scopus 로고
    • Modes of failure of cemented stem-type femoral components: A radiographic analysis of loosening
    • Gruen TA, McNeice GM, Amstutz HC: Modes of failure of cemented stem-type femoral components: A radiographic analysis of loosening. Clin Orthop 141:17-27, 1979.
    • (1979) Clin Orthop , vol.141 , pp. 17-27
    • Gruen, T.A.1    McNeice, G.M.2    Amstutz, H.C.3
  • 19
    • 0028798063 scopus 로고
    • The problem is osteolysis
    • Harris WH: The problem is osteolysis. Clin Orthop 311:46-53, 1995.
    • (1995) Clin Orthop , vol.311 , pp. 46-53
    • Harris, W.H.1
  • 20
    • 0027442645 scopus 로고
    • The rationale for cementless total hip replacement
    • Hungerford DS, Jones LC: The rationale for cementless total hip replacement. Orthop Clin North Am 24:617-624, 1993.
    • (1993) Orthop Clin North Am , vol.24 , pp. 617-624
    • Hungerford, D.S.1    Jones, L.C.2
  • 22
    • 0017053093 scopus 로고
    • In vitro measurement of boneacrylic interface pressure during femoral component insertion
    • Markolf KL, Amstutz HC: In vitro measurement of boneacrylic interface pressure during femoral component insertion. Clin Orthop 121:60-66, 1976.
    • (1976) Clin Orthop , vol.121 , pp. 60-66
    • Markolf, K.L.1    Amstutz, H.C.2
  • 23
    • 0017536083 scopus 로고
    • Degradation rates of oral resorbable implants: Rate modification with changes in PLA/PGA copolymer ratios
    • Miller RA, Brady JM, Cutright DE: Degradation rates of oral resorbable implants: Rate modification with changes in PLA/PGA copolymer ratios. J Biomed Mater Res 11:711-719, 1977.
    • (1977) J Biomed Mater Res , vol.11 , pp. 711-719
    • Miller, R.A.1    Brady, J.M.2    Cutright, D.E.3
  • 24
    • 0021076942 scopus 로고
    • The femoral cement compactor. An improvement in cementing technique in total hip replacement
    • Oh I, Bourne RB, Harris WH: The femoral cement compactor. An improvement in cementing technique in total hip replacement. J Bone Joint Surg 65A:1335-1338, 1983.
    • (1983) J Bone Joint Surg , vol.65 A , pp. 1335-1338
    • Oh, I.1    Bourne, R.B.2    Harris, W.H.3
  • 25
    • 0028034465 scopus 로고
    • Fixation with biodegradable devices of acetabular components in a canine model
    • Otsuka NY, Binnington AG, Fornasier VL, Davey JR: Fixation with biodegradable devices of acetabular components in a canine model. Clin Orthop 306:250-255, 1994.
    • (1994) Clin Orthop , vol.306 , pp. 250-255
    • Otsuka, N.Y.1    Binnington, A.G.2    Fornasier, V.L.3    Davey, J.R.4
  • 26
    • 0021842535 scopus 로고
    • Biodegradable implants in fracture fixation: Early results of the treatment of fractures of the ankle
    • Rokkanen P, Vainionpaa S, Tormala P, et al: Biodegradable implants in fracture fixation: Early results of the treatment of fractures of the ankle. Lancet 1:1422-1424, 1985.
    • (1985) Lancet , vol.1 , pp. 1422-1424
    • Rokkanen, P.1    Vainionpaa, S.2    Tormala, P.3
  • 28
    • 0026603824 scopus 로고
    • Mechanisms of biodegradation of implantable polymers
    • Williams DF: Mechanisms of biodegradation of implantable polymers. Clin Mater 1:9-12, 1992.
    • (1992) Clin Mater , vol.1 , pp. 9-12
    • Williams, D.F.1
  • 29
    • 0027414965 scopus 로고
    • Reinsertion of the ruptured ulnar collateral ligament of the metacarpophalangeal joint with an adsorbable self-reinforced polylactide tack
    • Vihtonen K, Juutilainen T, Patiala H, Rokkanen P, Tormala P: Reinsertion of the ruptured ulnar collateral ligament of the metacarpophalangeal joint with an adsorbable self-reinforced polylactide tack. J Hand Surg 18B:200-203, 1993.
    • (1993) J Hand Surg , vol.18 B , pp. 200-203
    • Vihtonen, K.1    Juutilainen, T.2    Patiala, H.3    Rokkanen, P.4    Tormala, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.