메뉴 건너뛰기




Volumn 34, Issue 4 I, 1999, Pages 448-452

Observer variation in measured ST-segment elevation

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; ELECTROCARDIOGRAM; EMERGENCY MEDICINE; FIBRINOLYTIC THERAPY; HEART INFARCTION; HISTOGRAM; HUMAN; MAJOR CLINICAL STUDY; MEDICAL DECISION MAKING; MEDICAL STUDENT; PERFORMANCE; PHYSICIAN ATTITUDE; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; RESIDENT; ST SEGMENT ELEVATION;

EID: 0032852035     PISSN: 01960644     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0196-0644(99)80045-6     Document Type: Article
Times cited : (19)

References (10)
  • 1
    • 0001104909 scopus 로고
    • The measurement of interrater agreement
    • Fleiss JL The measurement of interrater agreement Statistical Methods for Rates and Proportions 2nd ed. 1995 John Wiley & Sons New York 212 236
    • (1995) , pp. 212-236
    • Fleiss, JL1
  • 2
    • 0022375290 scopus 로고
    • Prevention of myocardial damage in acute myocardial ischemia by early treatment with intravenous streptokinase
    • Koren G Weiss AT Hasin Y Prevention of myocardial damage in acute myocardial ischemia by early treatment with intravenous streptokinase N Engl J Med 313 1985 1384 1389
    • (1985) N Engl J Med , vol.313 , pp. 1384-1389
    • Koren, G1    Weiss, AT2    Hasin, Y3
  • 3
    • 84912681129 scopus 로고
    • Randomized trial of intravenous recombinant tissue-type plasminogen activator versus intravenous streptokinase in acute myocardial infarction: Report from the European Cooperative Study Group for Recombinant Tissue-type Plasminogen Activator
    • Verstraete M Bemard R Bory M Randomized trial of intravenous recombinant tissue-type plasminogen activator versus intravenous streptokinase in acute myocardial infarction: Report from the European Cooperative Study Group for Recombinant Tissue-type Plasminogen Activator Lancet 1 1985 842 847
    • (1985) Lancet , vol.1 , pp. 842-847
    • Verstraete, M1    Bemard, R2    Bory, M3
  • 4
    • 0011279777 scopus 로고
    • Observer variation in reports on electrocardiograms
    • Davies LG Observer variation in reports on electrocardiograms Br Heart J 20 1958 153 161
    • (1958) Br Heart J , vol.20 , pp. 153-161
    • Davies, LG1
  • 5
    • 0005614753 scopus 로고
    • The electrocardiogram and its interpretation: A study of reports by 20 physicians on a set of 100 electrocardiograms
    • Segall HN The electrocardiogram and its interpretation: A study of reports by 20 physicians on a set of 100 electrocardiograms Can Med Assoc J 82 1960 2 6
    • (1960) Can Med Assoc J , vol.82 , pp. 2-6
    • Segall, HN1
  • 6
    • 0026689595 scopus 로고
    • Interpretation of the electrocardiogram in suspected myocardial infarction: A randomized controlled study of the effect of a training programme to reduce interobserver variation
    • Gjorup T Kalbaek H Nielsen D Interpretation of the electrocardiogram in suspected myocardial infarction: A randomized controlled study of the effect of a training programme to reduce interobserver variation J Intern Med 231 1992 407 412
    • (1992) J Intern Med , vol.231 , pp. 407-412
    • Gjorup, T1    Kalbaek, H2    Nielsen, D3
  • 7
    • 0026749794 scopus 로고
    • Physician electrocardiogram reading in the emergency department—Accuracy and effect on triage decisions: Findings from a multicenter study
    • Jayes RL Jr Larsen GC Bshansky JR Physician electrocardiogram reading in the emergency department—Accuracy and effect on triage decisions: Findings from a multicenter study J Gen Intern Med 7 1992 387 392
    • (1992) J Gen Intern Med , vol.7 , pp. 387-392
    • Jayes, RL1    Larsen, GC2    Bshansky, JR3
  • 8
    • 0031111522 scopus 로고    scopus 로고
    • Computer versus manual measurement of ST-segment deviation
    • Pelter MM Adams MG Drew BJ Computer versus manual measurement of ST-segment deviation J Electrocardiol 30 1997 151 156
    • (1997) J Electrocardiol , vol.30 , pp. 151-156
    • Pelter, MM1    Adams, MG2    Drew, BJ3
  • 9
    • 0025001755 scopus 로고
    • An off-line digital system for reproducible interpretation of the exercise ECG
    • Caralis DG Wiens G Shaw L An off-line digital system for reproducible interpretation of the exercise ECG J Electrocadiol 23 1990 285 291
    • (1990) J Electrocadiol , vol.23 , pp. 285-291
    • Caralis, DG1    Wiens, G2    Shaw, L3
  • 10
    • 0032126372 scopus 로고    scopus 로고
    • Differences between local investigator and core laboratory interpretation of the admission electrocardiogram in patients with unstable angina pectoris or non-Q-wave myocardial infarction (A Thrombin Inhibition in Myocardial Ischemia [TRIM] substudy)
    • Holmvang L Hasbak P Clemmensen P Differences between local investigator and core laboratory interpretation of the admission electrocardiogram in patients with unstable angina pectoris or non-Q-wave myocardial infarction (A Thrombin Inhibition in Myocardial Ischemia [TRIM] substudy) Am J Cardiol 82 1998 54 60
    • (1998) Am J Cardiol , vol.82 , pp. 54-60
    • Holmvang, L1    Hasbak, P2    Clemmensen, P3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.