메뉴 건너뛰기




Volumn 13, Issue 5, 1999, Pages 541-544

Accidental intraaortic placement of a Greenfield filter

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ARTICLE; CASE REPORT; DEVICE; HEAD INJURY; HUMAN; HUMAN CELL; HUMAN TISSUE; IATROGENIC DISEASE; MALE; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; SURGICAL TECHNIQUE; VENA CAVA FILTER;

EID: 0032848710     PISSN: 08905096     EISSN: None     Source Type: Journal    
DOI: 10.1007/s100169900295     Document Type: Article
Times cited : (8)

References (23)
  • 2
    • 0028840044 scopus 로고
    • Comparative efficacy and complications of vena cava filters
    • Mohan CR, Hoballah JJ, Sharp WJ, et al. Comparative efficacy and complications of vena cava filters. J Vasc Surg 1995;21:235-246.
    • (1995) J Vasc Surg , vol.21 , pp. 235-246
    • Mohan, C.R.1    Hoballah, J.J.2    Sharp, W.J.3
  • 3
    • 0023788388 scopus 로고
    • Problems in placement of the Greenfield inferior vena cava filter
    • Goff JM Jr, Puyau FA, Rice JC, Kerstein MD. Problems in placement of the Greenfield inferior vena cava filter. Am Surg 1988;54:544-547.
    • (1988) Am Surg , vol.54 , pp. 544-547
    • Goff J.M., Jr.1    Puyau, F.A.2    Rice, J.C.3    Kerstein, M.D.4
  • 4
    • 0025630638 scopus 로고
    • Acute myocardial infarction resulting from the migration of a Greenfield filter
    • Puram B, Maley TJ, White NM, et al. Acute myocardial infarction resulting from the migration of a Greenfield filter. Chest 1990;98:1510-1511.
    • (1990) Chest , vol.98 , pp. 1510-1511
    • Puram, B.1    Maley, T.J.2    White, N.M.3
  • 5
    • 0029800522 scopus 로고    scopus 로고
    • Tricuspid insufficiency after intracardiac migration of a Greenfield filter: Case report and review of the literature
    • James KV, Sobolewski AP, Lorh JM, Welling RE. Tricuspid insufficiency after intracardiac migration of a Greenfield filter: case report and review of the literature. J Vasc Surg 1996;24:494-498.
    • (1996) J Vasc Surg , vol.24 , pp. 494-498
    • James, K.V.1    Sobolewski, A.P.2    Lorh, J.M.3    Welling, R.E.4
  • 6
    • 0025654964 scopus 로고
    • Perforation of the vena cava with aortic penetration by a Greenfield filter: Diagnostic ability of ultrasonography
    • Angeli E, Paesano PL, Zanello A, Del Maschio A. Perforation of the vena cava with aortic penetration by a Greenfield filter: diagnostic ability of ultrasonography. Radiol Med 1990;80:929-931.
    • (1990) Radiol Med , vol.80 , pp. 929-931
    • Angeli, E.1    Paesano, P.L.2    Zanello, A.3    Del Maschio, A.4
  • 7
    • 0024335849 scopus 로고
    • Spontaneous fatal perforation of aorta and vena cava by Mobin-Uddin umbrella
    • Rozin L, Perper JA. Spontaneous fatal perforation of aorta and vena cava by Mobin-Uddin umbrella. Am J Forensic Med Pathol 1989;10:149-151.
    • (1989) Am J Forensic Med Pathol , vol.10 , pp. 149-151
    • Rozin, L.1    Perper, J.A.2
  • 8
    • 0029113444 scopus 로고
    • Late complication of a Greenfield filter associating caudal migration and perforation of the abdominal aorta by a ruptured strut
    • Dabbagh A, Chakfe N, Kretz J-G, et al. Late complication of a Greenfield filter associating caudal migration and perforation of the abdominal aorta by a ruptured strut. J Vasc Surg 1995;22:182-187.
    • (1995) J Vasc Surg , vol.22 , pp. 182-187
    • Dabbagh, A.1    Chakfe, N.2    Kretz, J.-G.3
  • 9
    • 0025975719 scopus 로고
    • Late arterial hemorrhage secondary to a Greenfield filter requiring operative intervention
    • Howerton RM, Watkins M, Feldman L. Late arterial hemorrhage secondary to a Greenfield filter requiring operative intervention. Surgery 1991:109:265-268.
    • (1991) Surgery , vol.109 , pp. 265-268
    • Howerton, R.M.1    Watkins, M.2    Feldman, L.3
  • 10
    • 0027957930 scopus 로고
    • The transjugular intrahepatic portosystemic stent-shunt procedure for variceal bleeding
    • Rossle M, Haag K, Ochs A, et al. The transjugular intrahepatic portosystemic stent-shunt procedure for variceal bleeding. N Engl J Med 1994;330:165-171.
    • (1994) N Engl J Med , vol.330 , pp. 165-171
    • Rossle, M.1    Haag, K.2    Ochs, A.3
  • 11
    • 0025960042 scopus 로고
    • Angiographic follow-up after placement of a self-expanding coronary-artery stent
    • Serruys PW, Strauss BH, Beatt KJ, et al. Angiographic follow-up after placement of a self-expanding coronary-artery stent. N Engl J Med 1991;324:13-17.
    • (1991) N Engl J Med , vol.324 , pp. 13-17
    • Serruys, P.W.1    Strauss, B.H.2    Beatt, K.J.3
  • 12
    • 0028218404 scopus 로고
    • Reaction to injury following balloon angioplasty and intravascular stent placement in the canine femoral artery
    • Salam TA, Taylor B, Suggs WD, et al. Reaction to injury following balloon angioplasty and intravascular stent placement in the canine femoral artery. Ann Surg 1994;60:353-357.
    • (1994) Ann Surg , vol.60 , pp. 353-357
    • Salam, T.A.1    Taylor, B.2    Suggs, W.D.3
  • 13
    • 0028289006 scopus 로고
    • The role of elastic recoil after balloon angioplasty of rabbit arteries and its prevention by stent implantation
    • Hehrlein C, Zimmermann M, Pill J, et al. The role of elastic recoil after balloon angioplasty of rabbit arteries and its prevention by stent implantation. Eur Heart J 1994;15:277-280.
    • (1994) Eur Heart J , vol.15 , pp. 277-280
    • Hehrlein, C.1    Zimmermann, M.2    Pill, J.3
  • 14
    • 0025745269 scopus 로고
    • Percutaneous iliac artery stent: Angiographic long-term follow-up
    • Long AL, Page PE, Raynaud AC, et al. Percutaneous iliac artery stent: angiographic long-term follow-up. Radiology 1991;180:771-778.
    • (1991) Radiology , vol.180 , pp. 771-778
    • Long, A.L.1    Page, P.E.2    Raynaud, A.C.3
  • 15
    • 0027396882 scopus 로고
    • Preliminary observations on the use of the Palmaz stent in the distal portion of the abdominal aorta
    • Diethrich EB, Santiago O, Gustafson G, Heuser RR. Preliminary observations on the use of the Palmaz stent in the distal portion of the abdominal aorta. Am Heart J 1993;125:490-501.
    • (1993) Am Heart J , vol.125 , pp. 490-501
    • Diethrich, E.B.1    Santiago, O.2    Gustafson, G.3    Heuser, R.R.4
  • 16
    • 0028061624 scopus 로고
    • Balloon angioplasty with intraluminal stenting as the initial treatment modality in aorto-iliac occlusive disease
    • Williams JB, Watts PW, Nguyen VA, Peterson CL. Balloon angioplasty with intraluminal stenting as the initial treatment modality in aorto-iliac occlusive disease. Am J Surg 1994;168:202-204.
    • (1994) Am J Surg , vol.168 , pp. 202-204
    • Williams, J.B.1    Watts, P.W.2    Nguyen, V.A.3    Peterson, C.L.4
  • 17
    • 0026080868 scopus 로고
    • Iliac artery stenosis or obstruction after unsuccessful balloon angioplasty: Treatment with a self-expandable stent
    • Gunther RW, Vorwerk D, Antonucci F, et al. Iliac artery stenosis or obstruction after unsuccessful balloon angioplasty: treatment with a self-expandable stent. AJR Am J Roentgenol 1991;156:389-393.
    • (1991) AJR Am J Roentgenol , vol.156 , pp. 389-393
    • Gunther, R.W.1    Vorwerk, D.2    Antonucci, F.3
  • 18
    • 0024333946 scopus 로고
    • Comparative analysis of retroperitoneal and transperitoneal aortic replacement for aneurysm
    • Leather RP, Shah DM, Kaufman JL, et al. Comparative analysis of retroperitoneal and transperitoneal aortic replacement for aneurysm. Surg Gynecol Obstet 1989;168:387-393.
    • (1989) Surg Gynecol Obstet , vol.168 , pp. 387-393
    • Leather, R.P.1    Shah, D.M.2    Kaufman, J.L.3
  • 19
    • 0028019776 scopus 로고
    • Staging of fixation and retrievability of Greenfield filters
    • Greenfield LJ, Proctor MC, James EA, et al. Staging of fixation and retrievability of Greenfield filters. J Vasc Surg 1994; 20:744-750.
    • (1994) J Vasc Surg , vol.20 , pp. 744-750
    • Greenfield, L.J.1    Proctor, M.C.2    James, E.A.3
  • 21
    • 0021208245 scopus 로고
    • Pelvic hemorrhage after percutaneous femoral angiography
    • Kaufman JL. Pelvic hemorrhage after percutaneous femoral angiography. AJR Am J Roentgenol 1984;143:335-336.
    • (1984) AJR Am J Roentgenol , vol.143 , pp. 335-336
    • Kaufman, J.L.1
  • 22
    • 0025328552 scopus 로고
    • Errant percutaneous Greenfield filter placement into the retroperitoneum
    • Adye BA, Raabe RD, Zobell RL. Errant percutaneous Greenfield filter placement into the retroperitoneum. J Vasc Surg 1990;12:60-61.
    • (1990) J Vasc Surg , vol.12 , pp. 60-61
    • Adye, B.A.1    Raabe, R.D.2    Zobell, R.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.