메뉴 건너뛰기




Volumn 21, Issue 5, 1999, Pages 343-352

Toward a portable blood pressure recorder device equipped with an accelerometer

Author keywords

Accelerometer; Ambulatory blood pressure; Anti hypertensive drugs; Modeling

Indexed keywords

ACCELEROMETERS; BLOOD; PORTABLE EQUIPMENT; PRESSURE MEASUREMENT;

EID: 0032844844     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1350-4533(99)00059-4     Document Type: Article
Times cited : (8)

References (10)
  • 1
    • 0025690705 scopus 로고
    • Smoothing twenty-four ambulatory blood pressures profiles: A comparison of alternative methods
    • Streiberg B., Meyer-Sabelleck W. Smoothing twenty-four ambulatory blood pressures profiles: a comparison of alternative methods. J. Hypertension. 8(6):1990;S21-S27.
    • (1990) J. Hypertension , vol.8 , Issue.6
    • Streiberg, B.1    Meyer-Sabelleck, W.2
  • 2
    • 0019215210 scopus 로고
    • The influence of physical activity on arterial pressure during ambulatory recordings in man
    • Rowlands D., Stallard T., Watson R., Littler W. The influence of physical activity on arterial pressure during ambulatory recordings in man. Clin. Sci. 58:1980;115-117.
    • (1980) Clin. Sci. , vol.58 , pp. 115-117
    • Rowlands, D.1    Stallard, T.2    Watson, R.3    Littler, W.4
  • 3
    • 0027215803 scopus 로고
    • A comparison of ambulatory blood pressure and heart rate at home and work on work and non-work days
    • Pieper C., Warren K., Pickering T. A comparison of ambulatory blood pressure and heart rate at home and work on work and non-work days. J. Hypertension. 11:1993;177-183.
    • (1993) J. Hypertension , vol.11 , pp. 177-183
    • Pieper, C.1    Warren, K.2    Pickering, T.3
  • 5
    • 0031106807 scopus 로고    scopus 로고
    • A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity
    • Bouten C., Koekkoek K., Verduin M., Kodde R., Janssen J. A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity. IEEE Trans. Biomed. Engng. 44(3):1997;136-147.
    • (1997) IEEE Trans. Biomed. Engng , vol.44 , Issue.3 , pp. 136-147
    • Bouten, C.1    Koekkoek, K.2    Verduin, M.3    Kodde, R.4    Janssen, J.5
  • 6
    • 84944374730 scopus 로고
    • Blood pressure during normal daily activities, sleep, and exercise. Comparison of values in normal and hypertensive subjects
    • Pickering T., Harsfield G., Kleinert H., Blank S., Laragh J. Blood pressure during normal daily activities, sleep, and exercise. Comparison of values in normal and hypertensive subjects. JAMA. 247(7):1982;992-996.
    • (1982) JAMA , vol.247 , Issue.7 , pp. 992-996
    • Pickering, T.1    Harsfield, G.2    Kleinert, H.3    Blank, S.4    Laragh, J.5
  • 7
    • 0027516276 scopus 로고
    • Diurnal blood pressure variability and physical activity measured electronically and by diary
    • Gretler D., Carlson G., Montano A., Murphy M. Diurnal blood pressure variability and physical activity measured electronically and by diary. Am. J. Hypertension. 6:1993;127-133.
    • (1993) Am. J. Hypertension , vol.6 , pp. 127-133
    • Gretler, D.1    Carlson, G.2    Montano, A.3    Murphy, M.4
  • 8
    • 0023237973 scopus 로고
    • A quantitative analysis of the effects of activity and time of day on the diurnal variations of blood pressure
    • Clark A., Denby L., Pregibon D., Harshfield G., Pickering T.G., Blank S., Laragh J.H. A quantitative analysis of the effects of activity and time of day on the diurnal variations of blood pressure. J. Chron. Disease. 40(7):1987;671-681.
    • (1987) J. Chron. Disease , vol.40 , Issue.7 , pp. 671-681
    • Clark, A.1    Denby, L.2    Pregibon, D.3    Harshfield, G.4    Pickering, T.G.5    Blank, S.6    Laragh, J.H.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.