Volumn 24, Issue 7, 1999, Pages 793-797

Vascular access devices used during harvest of peripheral blood stem cells: High complication rate in patients with a long-term dialysis central venous catheter

Author keywords

Central venous access; Central venous catheter; Complication; Harvest; PBSC collection; Thrombosis

Indexed keywords

ALTEPLASE;

EID: 0032837871     PISSN: 02683369     EISSN: None     Source Type: Journal    
DOI: 10.1038/sj.bmt.1701988     Document Type: Article
Times cited : (15)

References (23)
  • 1
    • 0031047784 scopus 로고    scopus 로고
    • Blood and marrow transplantation activity in Europe 1995
    • Gratwohl A, Hermans J, Baldomero H. Blood and marrow transplantation activity in Europe 1995. Bone Marrow Transplant 1997; 19: 407-419.
    • (1997) Bone Marrow Transplant , vol.19 , pp. 407-419
    • Gratwohl, A.1    Hermans, J.2    Baldomero, H.3
  • 2
    • 0028963895 scopus 로고
    • Large-bore central venous catheters for the collection of peripheral blood stem cells
    • Hahn U, Goldschmidt H, Salwender H et al. Large-bore central venous catheters for the collection of peripheral blood stem cells. J Clin Apheresis 1995; 10: 12-16.
    • (1995) J Clin Apheresis , vol.10 , pp. 12-16
    • Hahn, U.1    Goldschmidt, H.2    Salwender, H.3
  • 3
    • 0030909130 scopus 로고    scopus 로고
    • Complications associated with central venous catheters used for the collection of peripheral stem cells to support high-dose chemotherapy and autologous stem-cell rescue
    • Meisenberg BR, Callaghan M, Sloan C et al. Complications associated with central venous catheters used for the collection of peripheral stem cells to support high-dose chemotherapy and autologous stem-cell rescue. Support Care Cancer 1997; 5: 223-227.
    • (1997) Support Care Cancer , vol.5 , pp. 223-227
    • Meisenberg, B.R.1    Callaghan, M.2    Sloan, C.3
  • 4
    • 0024539684 scopus 로고
    • Successful use of double-lumen silicone rubber catheters for permanent hemodialysis access
    • Shusterman NH, Kloss K, Mullen JL. Successful use of double-lumen silicone rubber catheters for permanent hemodialysis access. Kidney Int 1989; 35: 887-890.
    • (1989) Kidney Int , vol.35 , pp. 887-890
    • Shusterman, N.H.1    Kloss, K.2    Mullen, J.L.3
  • 5
    • 0025094473 scopus 로고
    • Use of a silicone duallumen catheter with a dacron cuff as a long-term access for hemodialysis patients
    • Moss AH, Vasilakis C, Holley JL et al. Use of a silicone duallumen catheter with a dacron cuff as a long-term access for hemodialysis patients. Am J Kidney Dis 1990; 16: 211-215.
    • (1990) Am J Kidney Dis , vol.16 , pp. 211-215
    • Moss, A.H.1    Vasilakis, C.2    Holley, J.L.3
  • 6
    • 0025871822 scopus 로고
    • Five years experience with the Quinton PermCath for vascular access
    • Gibson SP, Mosquera D. Five years experience with the Quinton PermCath for vascular access. Nephrol Dial Transplant 1991; 6: 269-274.
    • (1991) Nephrol Dial Transplant , vol.6 , pp. 269-274
    • Gibson, S.P.1    Mosquera, D.2
  • 7
    • 0026551235 scopus 로고
    • Use of dacron cuffed silicone catheters as long-term hemodialysis access
    • Shaffer D, Madras PN, Williams ME et al. Use of dacron cuffed silicone catheters as long-term hemodialysis access. ASAIO J 1992; 38: 55-58.
    • (1992) ASAIO J , vol.38 , pp. 55-58
    • Shaffer, D.1    Madras, P.N.2    Williams, M.E.3
  • 8
    • 0028107039 scopus 로고
    • Transesophageal echocardiographic assessment of superior vena cava thrombosis in patients with long-term central venous hemodialysis catheters
    • Grote J, Lufft V, Nikutta P et al. Transesophageal echocardiographic assessment of superior vena cava thrombosis in patients with long-term central venous hemodialysis catheters. Clin Nephrol 1994; 42: 183-188.
    • (1994) Clin Nephrol , vol.42 , pp. 183-188
    • Grote, J.1    Lufft, V.2    Nikutta, P.3
  • 9
    • 0029071360 scopus 로고
    • Percutaneously inserted silastic jugular hemodialysis catheters seldom cause jugular vein thrombosis
    • Agraharkar M, Isaacson S, Mendelssohn D et al. Percutaneously inserted silastic jugular hemodialysis catheters seldom cause jugular vein thrombosis. ASAIO J 1995; 41: 169-172.
    • (1995) ASAIO J , vol.41 , pp. 169-172
    • Agraharkar, M.1    Isaacson, S.2    Mendelssohn, D.3
  • 10
    • 0029336486 scopus 로고
    • Lessons from vascular access procedures for hemodialysis
    • Shaffer D. Lessons from vascular access procedures for hemodialysis. Surg Oncol Clin N Am 1995; 4: 537-548.
    • (1995) Surg Oncol Clin N Am , vol.4 , pp. 537-548
    • Shaffer, D.1
  • 11
    • 0025689353 scopus 로고
    • Translumbar inferior vena cava catheters: Experience with 58 catheters in peripheral stem cell collection and transplantation
    • Haire WD, Lieberman RP, Lund GB et al. Translumbar inferior vena cava catheters: experience with 58 catheters in peripheral stem cell collection and transplantation. Transfus Sci 1990; 11: 195-200.
    • (1990) Transfus Sci , vol.11 , pp. 195-200
    • Haire, W.D.1    Lieberman, R.P.2    Lund, G.B.3
  • 13
    • 0028943487 scopus 로고
    • Change of central venous catheter dressings twice a week is superior to once a week in patients with haematological malignancies
    • Engervall P, Ringertz S, Hagman E et al. Change of central venous catheter dressings twice a week is superior to once a week in patients with haematological malignancies. J Hosp Infect 1995; 29: 275-286.
    • (1995) J Hosp Infect , vol.29 , pp. 275-286
    • Engervall, P.1    Ringertz, S.2    Hagman, E.3
  • 14
    • 0029153745 scopus 로고
    • Complications of peripheral blood stem cell harvesting: Review of 554 PBSC leukaphereses
    • Goldberg SL, Mangan TR, Klumpp TR et al. Complications of peripheral blood stem cell harvesting: review of 554 PBSC leukaphereses. J Hematother 1995; 4: 85-90.
    • (1995) J Hematother , vol.4 , pp. 85-90
    • Goldberg, S.L.1    Mangan, T.R.2    Klumpp, T.R.3
  • 15
    • 0029587645 scopus 로고
    • Increased incidence of central venous catheter-related infections in bone marrow transplant patients
    • Keung Y-K, Watkins K, Chen S-C et al. Increased incidence of central venous catheter-related infections in bone marrow transplant patients. Am J Clin Oncol 1995; 18: 469-474.
    • (1995) Am J Clin Oncol , vol.18 , pp. 469-474
    • Keung, Y.-K.1    Watkins, K.2    Chen, S.-C.3
  • 16
    • 0029262608 scopus 로고
    • Reducing central line catheter infections in bone marrow transplant patients
    • Richard-Smith A, Buh S. Reducing central line catheter infections in bone marrow transplant patients. Nurs Clin North Am 1995; 30: 45-51.
    • (1995) Nurs Clin North Am , vol.30 , pp. 45-51
    • Richard-Smith, A.1    Buh, S.2
  • 18
    • 0030161777 scopus 로고    scopus 로고
    • Comparison of central venous catheter dressings in bone marrow transplant recipients
    • Brandt B, DePalma J, Irwin M et al. Comparison of central venous catheter dressings in bone marrow transplant recipients. Oncol Nurs Forum 1996; 23: 829-836.
    • (1996) Oncol Nurs Forum , vol.23 , pp. 829-836
    • Brandt, B.1    Depalma, J.2    Irwin, M.3
  • 19
    • 0030183205 scopus 로고    scopus 로고
    • Guideline for prevention of intravascular device related infections
    • Hospital Infection Control Practices Advisory Committee
    • Pearson ML. Hospital Infection Control Practices Advisory Committee. Guideline for prevention of intravascular device related infections. Infect Control Hosp Epidemiol 1996; 17: 438-473.
    • (1996) Infect Control Hosp Epidemiol , vol.17 , pp. 438-473
    • Pearson, M.L.1
  • 20
    • 84942476317 scopus 로고
    • The relationship between the thrombotic and infectious complications of central venous catheters
    • Raad II, Luna M, Sayed-Ahmedh H et al. The relationship between the thrombotic and infectious complications of central venous catheters. JAMA 1994; 271: 1014-1016.
    • (1994) JAMA , vol.271 , pp. 1014-1016
    • Raad, I.I.1    Luna, M.2    Sayed-Ahmedh, H.3
  • 21
    • 0025237877 scopus 로고
    • Very low dose of warfarin can prevent thrombosis in central venous catheters
    • Bern M, Lokich J, Wallach S et al. Very low dose of warfarin can prevent thrombosis in central venous catheters. Am Coll Physicians 1990; 112: 423-428.
    • (1990) Am Coll Physicians , vol.112 , pp. 423-428
    • Bern, M.1    Lokich, J.2    Wallach, S.3
  • 22
    • 0031803169 scopus 로고    scopus 로고
    • Prevention of central venous catheter associated thrombosis using minidose warfarin in patients with haematological malignancies
    • Boraks P, Scale J, Price J et al. Prevention of central venous catheter associated thrombosis using minidose warfarin in patients with haematological malignancies. Br J Haematol 1998; 101: 483-486.
    • (1998) Br J Haematol , vol.101 , pp. 483-486
    • Boraks, P.1    Scale, J.2    Price, J.3
  • 23
    • 10544240763 scopus 로고    scopus 로고
    • Quinton-mahurkar catheter as short-term central venous access for PBSC collection: Single-center experience of 370 aphereses in 110 patients
    • Alegre A, Requena MJ, Fernández-Villalta MJ et al. Quinton-Mahurkar catheter as short-term central venous access for PBSC collection: single-center experience of 370 aphereses in 110 patients. Bone Marrow Transplant 1996; 18: 865-869.
    • (1996) Bone Marrow Transplant , vol.18 , pp. 865-869
    • Alegre, A.1    Requena, M.J.2    Fernández-Villalta, M.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.