-
1
-
-
0001397739
-
The evolution of upper-airway retraction: New and old laryngoscopy blades
-
Benumof JL (Ed.). St. Louis: Mosby
-
Cooper SD. The evolution of upper-airway retraction: new and old laryngoscopy blades. In: Benumof JL (Ed.). Airway Management. Principles and Practice. St. Louis: Mosby, 1996: 374-411.
-
(1996)
Airway Management. Principles and Practice
, pp. 374-411
-
-
Cooper, S.D.1
-
2
-
-
0028916427
-
Cervical spine movement during laryngoscopy with the Bullard, MacIntosh, and Miller laryngoscopes
-
Hastings RH, Vigil AC, Hanna R, Yang B-H, Sartoris DJ. Cervical spine movement during laryngoscopy with the Bullard, MacIntosh, and Miller laryngoscopes. Anesthesiology 1995; 82: 859-69.
-
(1995)
Anesthesiology
, vol.82
, pp. 859-869
-
-
Hastings, R.H.1
Vigil, A.C.2
Hanna, R.3
Yang, B.-H.4
Sartoris, D.J.5
-
3
-
-
0031454801
-
Comparison of the Bullard and Macintosh laryngoscopes for endotracheal intubation of patients with a potential cervical spine injury
-
Watts ADJ, Gelb AW, Bach DB, Pelz DM. Comparison of the Bullard and Macintosh laryngoscopes for endotracheal intubation of patients with a potential cervical spine injury. Anesthesiology 1997; 87: 1335-42.
-
(1997)
Anesthesiology
, vol.87
, pp. 1335-1342
-
-
Watts, A.D.J.1
Gelb, A.W.2
Bach, D.B.3
Pelz, D.M.4
-
4
-
-
0028302574
-
Nasal intubation with the Bullard laryngoscope: A useful approach for difficult airways
-
Shigematsu T, Miyazawa N, Kobayashi M, Yorozu T, Toyoda Y, Morisaki H. Nasal intubation with the Bullard laryngoscope: a useful approach for difficult airways. Anesth Analg 1994; 79: 132-5.
-
(1994)
Anesth Analg
, vol.79
, pp. 132-135
-
-
Shigematsu, T.1
Miyazawa, N.2
Kobayashi, M.3
Yorozu, T.4
Toyoda, Y.5
Morisaki, H.6
-
5
-
-
0025058913
-
The Bullard laryngoscope. A new indirect oral laryngoscope (pediatric version)
-
Borland LM, Casselbrant M. The Bullard laryngoscope. A new indirect oral laryngoscope (pediatric version). Anesth Analg 1990; 70: 105-8.
-
(1990)
Anesth Analg
, vol.70
, pp. 105-108
-
-
Borland, L.M.1
Casselbrant, M.2
-
6
-
-
0028908539
-
Awake intubation of the adult trachea using the Bullard laryngoscope
-
Cohn AI, McGraw SR, King WH. Awake intubation of the adult trachea using the Bullard laryngoscope. Can J Anaesth 1995; 42: 246-8.
-
(1995)
Can J Anaesth
, vol.42
, pp. 246-248
-
-
Cohn, A.I.1
McGraw, S.R.2
King, W.H.3
-
7
-
-
0029083309
-
The Bullard laryngoscope for emergency airway management in a morbidly obese parturient
-
Cohn AI, Hart RT, McGraw SR, Blass NH. The Bullard laryngoscope for emergency airway management in a morbidly obese parturient. Anesth Analg 1995; 81: 872-3.
-
(1995)
Anesth Analg
, vol.81
, pp. 872-873
-
-
Cohn, A.I.1
Hart, R.T.2
McGraw, S.R.3
Blass, N.H.4
-
8
-
-
0028847105
-
Awake endotracheal intubation in patients with cervical spine disease: A comparison of the Bullard laryngoscope and the fiberoptic bronchoscope
-
Cohn AI, Zornow MH. Awake endotracheal intubation in patients with cervical spine disease: a comparison of the Bullard laryngoscope and the fiberoptic bronchoscope. Anesth Analg 1995; 81: 1283-6.
-
(1995)
Anesth Analg
, vol.81
, pp. 1283-1286
-
-
Cohn, A.I.1
Zornow, M.H.2
-
9
-
-
0030038018
-
Use of the Bullard laryngoscope blade in patients with maxillofacial injuries
-
Gbouri AF, Bernstein CA. Use of the Bullard laryngoscope blade in patients with maxillofacial injuries (Letter). Anesthesiology 1996; 84: 490.
-
(1996)
Anesthesiology
, vol.84
, pp. 490
-
-
Gbouri, A.F.1
Bernstein, C.A.2
-
10
-
-
0025748830
-
Management of the challenging airway with the Bullard laryngoscope
-
Gorback MS. Management of the challenging airway with the Bullard laryngoscope. J Clin Anesth 1991; 3: 473-7.
-
(1991)
J Clin Anesth
, vol.3
, pp. 473-477
-
-
Gorback, M.S.1
-
11
-
-
2642634792
-
The adult Bullard laryngoscope in paediatric patients
-
Shulman GB, Connelly NR, Gibson C. The adult Bullard laryngoscope in paediatric patients. Can J Anaesth 1997; 44: 969-72.
-
(1997)
Can J Anaesth
, vol.44
, pp. 969-972
-
-
Shulman, G.B.1
Connelly, N.R.2
Gibson, C.3
-
12
-
-
0000416396
-
Clinical assessment of the adult Bullard laryngoscope
-
Saunders PR, Geisecke AH. Clinical assessment of the adult Bullard laryngoscope. Can J Anaesth 1989; 36: S118-9.
-
(1989)
Can J Anaesth
, vol.36
-
-
Saunders, P.R.1
Geisecke, A.H.2
-
14
-
-
0021701206
-
Difficult tracheal intubation in Obstetrics
-
Cormack RS, Lehane J. Difficult tracheal intubation in Obstetrics. Anaesthesia 1984; 39: 1105-11.
-
(1984)
Anaesthesia
, vol.39
, pp. 1105-1111
-
-
Cormack, R.S.1
Lehane, J.2
-
15
-
-
4243235972
-
Tracheal intubation using a gum elastic bougie for patients with restricted cervical spine movement
-
McNeil P, Hung OR. Tracheal intubation using a Gum Elastic Bougie for patients with restricted cervical spine movement. Can J Anaesth 1996; 43: A26.
-
(1996)
Can J Anaesth
, vol.43
-
-
McNeil, P.1
Hung, O.R.2
-
16
-
-
17544391230
-
Forced air warming can facilitate fiberoptic intubations
-
Dunn SM, Pulai I. Forced air warming can facilitate fiberoptic intubations (Letter). Anesthesiology 1998; 88: 282.
-
(1998)
Anesthesiology
, vol.88
, pp. 282
-
-
Dunn, S.M.1
Pulai, I.2
-
17
-
-
0028834689
-
Techniques using the Bullard laryngoscope
-
Crosby ET. Techniques using the Bullard laryngoscope (Letter). Anesth Analg 1995; 81: 1314.
-
(1995)
Anesth Analg
, vol.81
, pp. 1314
-
-
Crosby, E.T.1
-
19
-
-
0028104556
-
Evaluation of the Bullard laryngoscope using the new intubating stylet: Comparison with conventional laryngoscopy
-
Cooper SD, Benumof JL, Ozaki GT. Evaluation of the Bullard laryngoscope using the new intubating stylet: comparison with conventional laryngoscopy. Anesth Analg 1994; 79: 965-70.
-
(1994)
Anesth Analg
, vol.79
, pp. 965-970
-
-
Cooper, S.D.1
Benumof, J.L.2
Ozaki, G.T.3
-
20
-
-
0023150275
-
Cardiovascular and catecholamine responses to laryngoscopy with and without tracheal intubation
-
Shribman AJ, Smith G, Achola KJ. Cardiovascular and catecholamine responses to laryngoscopy with and without tracheal intubation. Br J Anaesth 1987; 59: 295-9.
-
(1987)
Br J Anaesth
, vol.59
, pp. 295-299
-
-
Shribman, A.J.1
Smith, G.2
Achola, K.J.3
|