메뉴 건너뛰기




Volumn 48, Issue 2, 1999, Pages 230-234

Difference in security of stent jail between Palmaz-Schatz, NIR, and multi-link stents: The effect of balloon inflation through stent struts

Author keywords

Angioplasty; Coronary artery disease; Stent

Indexed keywords

ARTICLE; BALLOON CATHETER; BALLOON DILATATION; CORONARY ARTERY DISEASE; CORONARY STENT; STENOSIS;

EID: 0032834083     PISSN: 15221946     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-726X(199910)48:2<230::AID-CCD25>3.0.CO;2-B     Document Type: Article
Times cited : (16)

References (8)
  • 3
    • 0000992850 scopus 로고    scopus 로고
    • Coronary stent implantation in bifurcational lesions: Immediate and follow-up results
    • Kobayashi Y, Colombo A, Reimers B, Di Mario C. Coronary stent implantation in bifurcational lesions: immediate and follow-up results. Circulation 1997;96:I693.
    • (1997) Circulation , vol.96
    • Kobayashi, Y.1    Colombo, A.2    Reimers, B.3    Di Mario, C.4
  • 4
    • 0002560229 scopus 로고    scopus 로고
    • Intravascular ultrasound identification of stent deformity after kissing balloon inflation
    • Kobayashi Y, Di Mario C, Akiyama T, Reimers B, Colombo A. Intravascular ultrasound identification of stent deformity after kissing balloon inflation. Intravasc Imaging 1997;1:91-92.
    • (1997) Intravasc Imaging , vol.1 , pp. 91-92
    • Kobayashi, Y.1    Di Mario, C.2    Akiyama, T.3    Reimers, B.4    Colombo, A.5
  • 5
    • 0028020558 scopus 로고
    • Comparison of three coronary stents: Clinical and angiographicoutcome after elective placement in 134 consecutive patients
    • MacIsaac AI, Ellis SG, Muller DW, Topol EJ, Whitlow PL. Comparison of three coronary stents: clinical and angiographicoutcome after elective placement in 134 consecutive patients. Cathet Cardiovasc Diagn 1994;33:199-204.
    • (1994) Cathet Cardiovasc Diagn , vol.33 , pp. 199-204
    • MacIsaac, A.I.1    Ellis, S.G.2    Muller, D.W.3    Topol, E.J.4    Whitlow, P.L.5
  • 7
    • 0041797886 scopus 로고    scopus 로고
    • Immediate and follow-up results following implantation of the long and short NIR stent: Comparison with the Palmaz-Schatz stent
    • Kobayashi Y, De Gregorio J, Reimers B, Di Mario C, Finci L, Colombo A. Immediate and follow-up results following implantation of the long and short NIR stent: comparison with the Palmaz-Schatz stent. J Am Coll Cardiol 1998;31:312A.
    • (1998) J Am Coll Cardiol , vol.31
    • Kobayashi, Y.1    De Gregorio, J.2    Reimers, B.3    Di Mario, C.4    Finci, L.5    Colombo, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.