메뉴 건너뛰기




Volumn 48, Issue 4, 1999, Pages 437-441

Measurement of and compensation for the difference between voltage and current centres in HRTEM

Author keywords

Current centre; HRTEM; Lens alignment; Lens axis; Optical axis; Voltage centre

Indexed keywords

'CURRENT; CURRENT CENTER; HIGH-RESOLUTION TRANSMISSION ELECTRON MICROSCOPES; LENS ALIGNMENT; LENS AXIS; MEASUREMENTS OF; OPTICAL AXIS; TRANSMISSION ELECTRON; VOLTAGE CENTER;

EID: 0032827973     PISSN: 00220744     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.jmicro.a023699     Document Type: Article
Times cited : (1)

References (9)
  • 2
    • 0344719255 scopus 로고    scopus 로고
    • Axis adjustment in high-resolution observation
    • Ishizuka K. (1996) Axis adjustment in high-resolution observation. Denshi-kenbikyo 30: 254-259.
    • (1996) Denshi-kenbikyo , vol.30 , pp. 254-259
    • Ishizuka, K.1
  • 3
    • 0011922691 scopus 로고
    • Capability of high-resolution objective lens with miniaturized lower pole piece top. I
    • Yanaka T, Shirota K, Yonezawa A, and Arai Y (1974) Capability of high-resolution objective lens with miniaturized lower pole piece top. I. 8th ICEM, Canberra 1: 128-129.
    • (1974) 8th ICEM, Canberra , vol.1 , pp. 128-129
    • Yanaka, T.1    Shirota, K.2    Yonezawa, A.3    Arai, Y.4
  • 7
    • 0018227155 scopus 로고
    • Coma-free alignment of high resolution electron microscopes with the aid of optical diffractograms
    • Zemlin F, Weiss K, Schiske P, Kunath W, and Herrmann K.-H. (1978) Coma-free alignment of high resolution electron microscopes with the aid of optical diffractograms. Ultramicroscopy 3: 49-60.
    • (1978) Ultramicroscopy , vol.3 , pp. 49-60
    • Zemlin, F.1    Weiss, K.2    Schiske, P.3    Kunath, W.4    Herrmann, K.-H.5
  • 8
    • 0028518917 scopus 로고
    • Coma-free alignment of a high-resolution electron microscope with three-fold astigmatism
    • Ishizuka K (1994) Coma-free alignment of a high-resolution electron microscope with three-fold astigmatism. Ultramicroscopy 55: 407-418.
    • (1994) Ultramicroscopy , vol.55 , pp. 407-418
    • Ishizuka, K.1
  • 9
    • 0030250541 scopus 로고    scopus 로고
    • Lens-field center alignment for high resolution electron microscopy
    • Ishizuka K and Shirota K (1996) Lens-field center alignment for high resolution electron microscopy. Ultramicroscopy 65: 71-79.
    • (1996) Ultramicroscopy , vol.65 , pp. 71-79
    • Ishizuka, K.1    Shirota, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.