메뉴 건너뛰기




Volumn 46, Issue 9, 1999, Pages 1037-1043

Estimation of blood perfusion using phase shift in temperature response to sinusoidal heating at the skin surface

Author keywords

Bio heat; Blood perfusion; Noninvasive estimation; Phase shift; Sinusoidal heating; Thermal contact resistance

Indexed keywords

HEAT FLUX; HEAT RESISTANCE; NONINVASIVE MEDICAL PROCEDURES; SKIN; TEMPERATURE DISTRIBUTION; TEMPERATURE MEASUREMENT;

EID: 0032820258     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/10.784134     Document Type: Article
Times cited : (110)

References (26)
  • 2
    • 0018885071 scopus 로고
    • Measurement of thermal properties of growing tumors
    • J. C. Chato, "Measurement of thermal properties of growing tumors," Ann. New York Academia Sei., vol. 335, pp. 67-85, 1980.
    • (1980) Ann. New York Academia Sei. , vol.335 , pp. 67-85
    • Chato, J.C.1
  • 3
    • 0003009870 scopus 로고
    • A method for the measurement of thermal properties of biological materials
    • New York: Amer. Soc. Mech. Eng.
    • "A method for the measurement of thermal properties of biological materials," in Thermal Problems in Biotechnology, LCN068-58741. New York: Amer. Soc. Mech. Eng., 1968, pp. 16-25.
    • (1968) Thermal Problems in Biotechnology, LCN068-58741. , pp. 16-25
  • 4
    • 0016093507 scopus 로고
    • Temperature field due to a time dependent heat source of spherical geometry in an infinite medium
    • T. A. Balasubramaniam and H. F. Bowman, "Temperature field due to a time dependent heat source of spherical geometry in an infinite medium," ASME J. Heat Transfer, vol. 93, pp. 296-299, 1974.
    • (1974) ASME J. Heat Transfer , vol.93 , pp. 296-299
    • Balasubramaniam, T.A.1    Bowman, H.F.2
  • 5
    • 0019644492 scopus 로고
    • Pulse decay method for measuring the thermal conductivity of living tissues
    • M. M. Chen, K. R. Holmes, and V. Rupinskas, "Pulse decay method for measuring the thermal conductivity of living tissues," ASMEJ. Biomech. Eng., vol. 103, pp. 253-260, 1981.
    • (1981) ASMEJ. Biomech. Eng. , vol.103 , pp. 253-260
    • Chen, M.M.1    Holmes, K.R.2    Rupinskas, V.3
  • 6
    • 0022762487 scopus 로고
    • A sensitivity analysis of the thermal pulse decay method for measurement of local tissue conductivity and blood perfusion
    • H. Arkin, K. R. Holmes, and M. M. Chen, "A sensitivity analysis of the thermal pulse decay method for measurement of local tissue conductivity and blood perfusion," ASME J. Biomech. Eng., vol. 108, pp. 208-214, 1986.
    • (1986) ASME J. Biomech. Eng. , vol.108 , pp. 208-214
    • Arkin, H.1    Holmes, K.R.2    Chen, M.M.3
  • 7
    • 0024764088 scopus 로고
    • "A technique for measuring the thermal conductivity and evaluating the 'apparent conductivity' concept in biomaterials," ASME J. Biomech. Eng., vol. Ill, pp. 276-282, 1989.
    • (1989) ASME J. Biomech. Eng. , vol.3 , pp. 276-282
    • Biomaterials, E.T.1
  • 8
    • 0002701802 scopus 로고
    • In vivo measurement of instrinsic and effective thermal conductivity using sinusoidally heated thermistors,"
    • J. W. Valvano and A. F. Badeau, "In vivo measurement of instrinsic and effective thermal conductivity using sinusoidally heated thermistors," in Proc. 6th Southern Biomédical Engineering Conf., 1987, pp. la-4a.
    • (1987) Proc. 6th Southern Biomédical Engineering Conf.
    • Valvano, J.W.1    Badeau, A.F.2
  • 11
    • 0021472250 scopus 로고
    • The simultaneous measurement of thermal conductivity, thermal diffusivity, and perfusion in small volumes of tissue
    • J. W. Valvano, J. T. Alien, and H. F. Bowman, "The simultaneous measurement of thermal conductivity, thermal diffusivity, and perfusion in small volumes of tissue," ASME J. Biomech. Eng., vol. 106, pp. 192-197, 1984.
    • (1984) ASME J. Biomech. Eng. , vol.106 , pp. 192-197
    • Valvano, J.W.1    Alien, J.T.2    Bowman, H.F.3
  • 12
    • 0025644135 scopus 로고
    • A noninvasive technique to measure perfusion using a focused ultrasound heating sources and a tissue surface temperature measurement
    • Dallas, Texas
    • G. T. Anderson and G. Burnside, "A noninvasive technique to measure perfusion using a focused ultrasound heating sources and a tissue surface temperature measurement," in Proc. Advances in Measuring and Computing Temperatures in Biomedicine: HTD-vol. 147, The Winter Annu. Meeting of ASME, Dallas, Texas, 1990, pp. 31-35.
    • (1990) Proc. Advances in Measuring and Computing Temperatures in Biomedicine: HTD , vol.147 , pp. 31-35
    • Anderson, G.T.1    Burnside, G.2
  • 13
    • 3342908080 scopus 로고    scopus 로고
    • Estimation of blood perfusion using a minimally invasive blood perfusion probe
    • New York: Amer. Soc. Mech. Eng.
    • E. P. Scott, P. Robinson, and T. E. Diller, "Estimation of blood perfusion using a minimally invasive blood perfusion probe," Advances in Biological Heat and Mass Transfer, HTD-vol. 355/BED, vol. 37. New York: Amer. Soc. Mech. Eng., 1997, pp. 205-212.
    • (1997) Advances in Biological Heat and Mass Transfer, HTD-vol. 355/BED , vol.37 , pp. 205-212
    • Scott, E.P.1    Robinson, P.2    Diller, T.E.3
  • 14
    • 3342885542 scopus 로고    scopus 로고
    • Development of a noninvasive blood perfusion probe
    • L. J. Hayes and S. Clegg, Eds. New York: Amer. Soc. Mech. Eng.
    • T. B. O'Reilly, T. L. Gonzales, and T. E. Diller, "Development of a noninvasive blood perfusion probe," in Advances in Biological Heat and Mass Transfer, HTD-vol. 337/BED, , vol. 34, L. J. Hayes and S. Clegg, Eds. New York: Amer. Soc. Mech. Eng., 1996, pp. 67-73.
    • (1996) Advances in Biological Heat and Mass Transfer, HTD-vol. 337/BED , vol.34 , pp. 67-73
    • O'Reilly, T.B.1    Gonzales, T.L.2    Diller, T.E.3
  • 15
  • 17
    • 0000046778 scopus 로고
    • Estimation of the nutrient skin blood flow using a noninvasive segmented thermal clearance probe
    • P. Rolfe, Ed. London, U.K.: Academic
    • G. Holti and K. W. Mitchell, "Estimation of the nutrient skin blood flow using a noninvasive segmented thermal clearance probe," in NonInvasive Physiological Measurements, vol. l, P. Rolfe, Ed. London, U.K.: Academic, 1979, pp. 113-123.
    • (1979) NonInvasive Physiological Measurements , vol.50 , pp. 113-123
    • Holti, G.1    Mitchell, K.W.2
  • 18
    • 0020613273 scopus 로고
    • Steadystate analysis and evaluation of a new thermal sensor for surface measurements of tissue perfusion
    • F. S. Castellana, R. Skalak, J. M. Cho, and R. B. Case, "Steadystate analysis and evaluation of a new thermal sensor for surface measurements of tissue perfusion," Ann. Biomed. Eng., vol. 11, pp. 101-115, 1983.
    • (1983) Ann. Biomed. Eng. , vol.11 , pp. 101-115
    • Castellana, F.S.1    Skalak, R.2    Cho, J.M.3    Case, R.B.4
  • 19
    • 0021575750 scopus 로고
    • A noninvasive technique for quantifying tissue perfusion
    • R. L. Spilker, Ed.. New York: Amer. Soc. Mech. Eng.
    • J. T. Walsh and H. F. Bowman, "A noninvasive technique for quantifying tissue perfusion," in Advaces in Bioengineering, R. L. Spilker, Ed.. New York: Amer. Soc. Mech. Eng., 1984, pp. 5-6.
    • (1984) Advaces in Bioengineering , pp. 5-6
    • Walsh, J.T.1    Bowman, H.F.2
  • 20
    • 0023454575 scopus 로고
    • A self-heated thermistor technique to measure effective thermal properties from the tissue surface
    • P. A. Patel, J. W. Valvano, J. A. Pearce, S. A. Prahl, and C. R. Denham, "A self-heated thermistor technique to measure effective thermal properties from the tissue surface," ASME J. Biomech. Eng., vol. 109, pp. 300-315, 1987.
    • (1987) ASME J. Biomech. Eng. , vol.109 , pp. 300-315
    • Patel, P.A.1    Valvano, J.W.2    Pearce, J.A.3    Prahl, S.A.4    Denham, C.R.5
  • 21
    • 84888360034 scopus 로고
    • Analysis of tissue and arterial blood temperatures in the resting human forearm
    • H. H. Pennes, "Analysis of tissue and arterial blood temperatures in the resting human forearm," J. Appl. Physiol., vol. 1, pp. 93-122, 1948.
    • (1948) J. Appl. Physiol. , vol.1 , pp. 93-122
    • Pennes, H.H.1
  • 23
    • 0000008151 scopus 로고
    • Estimation of tissue blood flow
    • A. Shitzer and R. C. Eberhart, Eds. New York, Plenum, 1985, ch. 9
    • H. F. Bowman, "Estimation of tissue blood flow," Heat Transfer in Medicine and Biology, vol. 1, A. Shitzer and R. C. Eberhart, Eds. New York, Plenum, 1985, ch. 9, pp. 193-230, 1985.
    • (1985) Heat Transfer in Medicine and Biology , vol.1 , pp. 193-230
    • Bowman, H.F.1
  • 24
    • 0029695476 scopus 로고    scopus 로고
    • New high sensitivity, low thermal resistance surface mounted heat flux transducer
    • J. P. Terrell, "New high sensitivity, low thermal resistance surface mounted heat flux transducer," in Proc. 42nd Int. Instrumentation Symp., 1996, pp. 235-249.
    • (1996) Proc. , vol.42 , pp. 235-249
    • Terrell, J.P.1
  • 25
    • 0025932804 scopus 로고
    • The influence of model parameter values on the prediction of skin surface temperature: II. Contact problems
    • Z. F. Cui and J. C. Barbenel, "The influence of model parameter values on the prediction of skin surface temperature: II. Contact problems," Phys. Med. Biol, vol. 36, pp. 1607-1620, 1991.
    • (1991) Phys. Med. Biol , vol.36 , pp. 1607-1620
    • Cui, Z.F.1    Barbenel, J.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.