-
1
-
-
0002836279
-
Mycobacterium
-
Murray P, Baron E, Pfaller M, Tenover F, Yolken R, editors Washington (DC): ASM Press
-
1. Nolte F, Metchock B. Mycobacterium. In: Murray P, Baron E, Pfaller M, Tenover F, Yolken R, editors. Manual of clinical microbiology Washington (DC): ASM Press; 1995. p. 400-37.
-
(1995)
Manual of Clinical Microbiology
, pp. 400-437
-
-
Nolte, F.1
Metchock, B.2
-
3
-
-
0002239984
-
Chemical disinfection of medical and surgical materials
-
Block SS, editor. Philadelphia: Lea & Febiger
-
3. Favero MS, Bond WW. Chemical disinfection of medical and surgical materials. In: Block SS, editor. Disinfection, sterilization, and preservation. Philadelphia: Lea & Febiger; 1991. p.617-41.
-
(1991)
Disinfection, Sterilization, and Preservation
, pp. 617-641
-
-
Favero, M.S.1
Bond, W.W.2
-
4
-
-
0002804124
-
Glutaraldehyde
-
Block SS, editor. Philadelphia: Lea & Febiger
-
4. Scott E, Gorman S. Glutaraldehyde. In: Block SS, editor. Disinfection, sterilization, and preservation. Philadelphia: Lea & Febiger; 1991. p. 596-616.
-
(1991)
Disinfection, Sterilization, and Preservation
, pp. 596-616
-
-
Scott, E.1
Gorman, S.2
-
5
-
-
0027674673
-
Glutaraldehyde resistant mycobacteria from endoscope washers
-
5. Van Klingeren B, Pullen W. Glutaraldehyde resistant mycobacteria from endoscope washers. J Hosp Infect 1993;25:145-9.
-
(1993)
J Hosp Infect
, vol.25
, pp. 145-149
-
-
Van Klingeren, B.1
Pullen, W.2
-
6
-
-
0030956701
-
Glutaraldehyde-resistant mycobacterium chelonae from endoscope washer disinfectors
-
6. Griffiths PA, Babb JR, Bradley CR, Fraise AP. Glutaraldehyde-resistant Mycobacterium chelonae from endoscope washer disinfectors. J Appl Microbiol 1997;82;519-26.
-
(1997)
J Appl Microbiol
, vol.82
, pp. 519-526
-
-
Griffiths, P.A.1
Babb, J.R.2
Bradley, C.R.3
Fraise, A.P.4
-
7
-
-
0029658354
-
Activity of biocides against mycobacteria
-
7. Russell AD. Activity of biocides against mycobacteria. J Appl Bacteriol 1996;81;87S-101S.
-
(1996)
J Appl Bacteriol
, vol.81
-
-
Russell, A.D.1
-
8
-
-
0028244675
-
Efficacy of selected disinfectants against mycobacteria and cryptosporidia
-
8. Holton J, Nye P, McDonald V. Efficacy of selected disinfectants against mycobacteria and cryptosporidia. J Hosp Infect 1994;27:105-15.
-
(1994)
J Hosp Infect
, vol.27
, pp. 105-115
-
-
Holton, J.1
Nye, P.2
McDonald, V.3
-
9
-
-
0028861878
-
Efficacy of 'Nu-Cidex' (0.35% peracetic acid) against mycobacteria and cryptosporidia
-
9. Holton J, Shetty N, McDonald V. Efficacy of 'Nu-Cidex' (0.35% peracetic acid) against mycobacteria and cryptosporidia. J Hosp Infect 1995;31:235-7.
-
(1995)
J Hosp Infect
, vol.31
, pp. 235-237
-
-
Holton, J.1
Shetty, N.2
McDonald, V.3
-
12
-
-
84980193947
-
Utersuchungen uber die bildung von persauren aus organischen sauren und hydroperoxyd
-
12. D'Ans J, Frey W. Utersuchungen uber die bildung von persauren aus organischen sauren und hydroperoxyd. Z Anorg Chem 1913;45:145-50.
-
(1913)
Z Anorg Chem
, vol.45
, pp. 145-150
-
-
D'Ans, J.1
Frey, W.2
-
13
-
-
0018459909
-
Microbiological applications of the inactivation of antibiotics and other antimicrobial agents
-
13. Russell AD, Ahonkhai I, Rogers DT. Microbiological applications of the inactivation of antibiotics and other antimicrobial agents. J Appl Bacteriol 1979;46:207-45.
-
(1979)
J Appl Bacteriol
, vol.46
, pp. 207-245
-
-
Russell, A.D.1
Ahonkhai, I.2
Rogers, D.T.3
-
14
-
-
0027516263
-
Sporocidal properties of peracetic acid and hydrogen peroxide, alone and in combination, in comparison with chlorine and formaldehyde for ultrafiltration membrane disinfection
-
14. Alasri A, Valverde M, Roques C, Michel G, Cabassud C, Aptel P. Sporocidal properties of peracetic acid and hydrogen peroxide, alone and in combination, in comparison with chlorine and formaldehyde for ultrafiltration membrane disinfection. Can J Microbiol 1993;39:52-60.
-
(1993)
Can J Microbiol
, vol.39
, pp. 52-60
-
-
Alasri, A.1
Valverde, M.2
Roques, C.3
Michel, G.4
Cabassud, C.5
Aptel, P.6
-
16
-
-
0020725123
-
Contamination of flexible fiberoptic bronchoscopes
-
16. Pappas S, Schaaf D, DiCostanzo MB, King FW, Sharp JT. Contamination of flexible fiberoptic bronchoscopes. Am Rev Respir Dis 1983;127;391-2.
-
(1983)
Am Rev Respir Dis
, vol.127
, pp. 391-392
-
-
Pappas, S.1
Schaaf, D.2
DiCostanzo, M.B.3
King, F.W.4
Sharp, J.T.5
-
17
-
-
0028694346
-
A pseudoepidemic of Mycobacterium chelonae: Contamination of a bronchoscope and autocleaner
-
17. Campagnaro RL, Teichtahl H, Dwyer B. A pseudoepidemic of Mycobacterium chelonae: contamination of a bronchoscope and autocleaner. Aust N Z J Med 1994;24:693-5.
-
(1994)
Aust N Z J Med
, vol.24
, pp. 693-695
-
-
Campagnaro, R.L.1
Teichtahl, H.2
Dwyer, B.3
-
18
-
-
0029079126
-
Eradication of contaminating mycobacterium chelonae from bronchofiberscopes and an automated bronchoscope disinfection machine
-
18. Takigavva K, Fujita J, Negayama K, Terada S, Yamaji Y, Kawanishi K, et al. Eradication of contaminating Mycobacterium chelonae from bronchofiberscopes and an automated bronchoscope disinfection machine. Respir Med 1995;89;423-7.
-
(1995)
Respir Med
, vol.89
, pp. 423-427
-
-
Takigavva, K.1
Fujita, J.2
Negayama, K.3
Terada, S.4
Yamaji, Y.5
Kawanishi, K.6
-
19
-
-
0029741787
-
Culture variability associated with the U.S. environmental protection agency tuberculocidal activity test method
-
19. Robison RR, Osguthorpe RJ, Carroll SJ, Levitt RW, Schaalje GB, Ascenzi JM. Culture variability associated with the U.S. Environmental Protection Agency tuberculocidal activity test method. Appl Environ Microbiol 1996;62:2681-6.
-
(1996)
Appl Environ Microbiol
, vol.62
, pp. 2681-2686
-
-
Robison, R.R.1
Osguthorpe, R.J.2
Carroll, S.J.3
Levitt, R.W.4
Schaalje, G.B.5
Ascenzi, J.M.6
-
22
-
-
0002215836
-
Disinfection with peroxygens
-
Payne KR, editor. New York: John Wiley & Sons
-
22. Baldry MGC, Fraser JAL. Disinfection with peroxygens. In: Payne KR, editor. Industrial biocides. New York: John Wiley & Sons; 1988. p. 91-116.
-
(1988)
Industrial Biocides
, pp. 91-116
-
-
Baldry, M.G.C.1
Fraser, J.A.L.2
-
24
-
-
0026675476
-
Bactericidal properties of peracetic acid and hydrogen peroxide, alone and in combination, and chlorine and formaldehyde against bacterial water strains
-
24. Alasri A, Roques C, Michel G, Cavassud C, Aptel P. Bactericidal properties of peracetic acid and hydrogen peroxide, alone and in combination, and chlorine and formaldehyde against bacterial water strains. Can J Microbiol 1992;38:625-42.
-
(1992)
Can J Microbiol
, vol.38
, pp. 625-642
-
-
Alasri, A.1
Roques, C.2
Michel, G.3
Cavassud, C.4
Aptel, P.5
-
25
-
-
85030365211
-
Use-dilution methods
-
Helrich D, editor. Arlington (VA): Association of Official Analytical Chemists
-
25. Association of Official Analytical Chemists. Use-dilution methods. In: Helrich D, editor. Official methods of analysis of the Association of Official Analytical Chemists. 15th ed. Arlington (VA): Association of Official Analytical Chemists; 1990. p. 135-7.
-
(1990)
Official Methods of Analysis of the Association of Official Analytical Chemists. 15th Ed.
, pp. 135-137
-
-
|