메뉴 건너뛰기




Volumn 24, Issue 9, 1999, Pages 660-665

Comparison between cortical distribution of I-123 lomazenil and Tc-99m HMPAO in patients with Alzheimer's disease using SPECT

Author keywords

Brain Perfusion; Gamma Aminobutyric Acid A Receptors; Synaptic Density; Tomography

Indexed keywords

4 AMINOBUTYRIC ACID A RECEPTOR; HEXAMETHYLPROPYLENE AMINE OXIME TECHNETIUM TC 99M; IODINE 123; IOMAZENIL;

EID: 0032817447     PISSN: 03639762     EISSN: None     Source Type: Journal    
DOI: 10.1097/00003072-199909000-00004     Document Type: Article
Times cited : (10)

References (31)
  • 1
    • 0023125174 scopus 로고
    • Cerebral perfusion imaging in Alzheimer's disease: Use of single photon emission computed tomography and iofetamine 1-123
    • Johnson KA, Mueller ST, Walshe TM, English RJ, Holman BL: Cerebral perfusion imaging in Alzheimer's disease: Use of single photon emission computed tomography and iofetamine 1-123. Arch Neurol 44:165, 1987.
    • (1987) Arch Neurol , vol.44 , pp. 165
    • Johnson, K.A.1    Mueller, S.T.2    Walshe, T.M.3    English, R.J.4    Holman, B.L.5
  • 2
    • 0026500789 scopus 로고
    • The scintigraphic appearance of Alzheimer's disease: A prospective study using Technetium-99m-HMPAO-SPECT
    • Holman BL, Johnson KA, Gerada B, Carvalho PA, Satlin A: The scintigraphic appearance of Alzheimer's disease: A prospective study using Technetium-99m-HMPAO-SPECT. J Nucl Med 33:181, 1992.
    • (1992) J Nucl Med , vol.33 , pp. 181
    • Holman, B.L.1    Johnson, K.A.2    Gerada, B.3    Carvalho, P.A.4    Satlin, A.5
  • 3
    • 0027445501 scopus 로고
    • Quantitative brain SPECT in Alzheimer's disease and normal aging
    • Johnson KA, Kijewski MF, Becker A, et al: Quantitative brain SPECT in Alzheimer's disease and normal aging. J Nucl Med 34:2044, 1993.
    • (1993) J Nucl Med , vol.34 , pp. 2044
    • Johnson, K.A.1    Kijewski, M.F.2    Becker, A.3
  • 4
    • 0028013696 scopus 로고
    • High-resolution Technetium-99m-HMPAO SPECT in patients with probable Alzheimer's disease: Comparison with fluorine-18-FDG PET
    • Messa C, Perani D, Lucignani G, et al: High-resolution Technetium-99m-HMPAO SPECT in patients with probable Alzheimer's disease: Comparison with fluorine-18-FDG PET. J Nucl Med 35:210, 1994.
    • (1994) J Nucl Med , vol.35 , pp. 210
    • Messa, C.1    Perani, D.2    Lucignani, G.3
  • 5
    • 0026300720 scopus 로고
    • Positron emission tomography in Alzheimer's disease in relation to disease pathogenesis: A critical review
    • Rapoport SI: Positron emission tomography in Alzheimer's disease in relation to disease pathogenesis: A critical review. Cerebrovascular and Brain Metabolism Reviews 3:297, 1991.
    • (1991) Cerebrovascular and Brain Metabolism Reviews , vol.3 , pp. 297
    • Rapoport, S.I.1
  • 6
    • 0038423217 scopus 로고
    • Biochemistry of senile dementia
    • Laitha A, ed. New York: Plenum Press
    • De Kosky ST, Bass NH: Biochemistry of senile dementia. In: Laitha A, ed. Handbook of Neurochemistry. New York: Plenum Press, 1985, pp 617-49.
    • (1985) Handbook of Neurochemistry , pp. 617-649
    • De Kosky, S.T.1    Bass, N.H.2
  • 7
    • 0024309958 scopus 로고
    • Aging, amyloid, and Alzheimer's disease
    • Selkoe DJ: Aging, amyloid, and Alzheimer's disease. N Engl J Med 320:1484, 1989.
    • (1989) N Engl J Med , vol.320 , pp. 1484
    • Selkoe, D.J.1
  • 8
    • 0019494341 scopus 로고
    • Some morphometric aspects of the brain in senile dementia of the Alzheimer type
    • Terry RD, Peck A, De Teresa R, Schlechter R, Horoupian DS: Some morphometric aspects of the brain in senile dementia of the Alzheimer type. Ann Neurol 10:184, 1981.
    • (1981) Ann Neurol , vol.10 , pp. 184
    • Terry, R.D.1    Peck, A.2    De Teresa, R.3    Schlechter, R.4    Horoupian, D.S.5
  • 9
    • 0023812818 scopus 로고
    • A variety of cerebral amyloid deposits in the brains of the Alzheimer-type dementia demonstrated by β-protein immunostaining
    • Yamaguchi F, Hirai S, Morimatso M, et al: A variety of cerebral amyloid deposits in the brains of the Alzheimer-type dementia demonstrated by β-protein immunostaining. Acta Neuropathol 76:541, 1988.
    • (1988) Acta Neuropathol , vol.76 , pp. 541
    • Yamaguchi, F.1    Hirai, S.2    Morimatso, M.3
  • 12
  • 13
    • 0025086191 scopus 로고
    • HMPAO-SpECT imaging resembling Alzheimer-type dementia in mitochondrial encephalomyopathy with lactic acidosis and stroke-like episodes (MELAS)
    • Grunwald F, Zierz S, Broich K, et al: HMPAO-SPECT imaging resembling Alzheimer-type dementia in mitochondrial encephalomyopathy with lactic acidosis and stroke-like episodes (MELAS). J Nucl Med 31:1740, 1990.
    • (1990) J Nucl Med , vol.31 , pp. 1740
    • Grunwald, F.1    Zierz, S.2    Broich, K.3
  • 14
    • 0025662006 scopus 로고
    • Differential diagnosis of bilateral parietal abnormalities in I-123 IMP SPECT imaging
    • Kuwabara Y, Ichiya Y, Otsuka M, et al: Differential diagnosis of bilateral parietal abnormalities in I-123 IMP SPECT imaging. Clin Nucl Med 15:893, 1990.
    • (1990) Clin Nucl Med , vol.15 , pp. 893
    • Kuwabara, Y.1    Ichiya, Y.2    Otsuka, M.3
  • 15
    • 0025975473 scopus 로고
    • SPECT imaging of the benzodiazepine receptor in non-human primate brain with [I-123]Ro 16-0154
    • Innis R, Zoghbi S, Johnson E, et al: SPECT imaging of the benzodiazepine receptor in non-human primate brain with [I-123]Ro 16-0154. Eur J Pharmacol 193:249, 1991.
    • (1991) Eur J Pharmacol , vol.193 , pp. 249
    • Innis, R.1    Zoghbi, S.2    Johnson, E.3
  • 16
    • 0026448375 scopus 로고
    • Dynamic SPECT imaging after the injection of the benzodiazepine receptor ligand [I-123]iomazenil in healthy human subjects
    • Woods SW, Seibyl JP, Goddard AW, et al: Dynamic SPECT imaging after the injection of the benzodiazepine receptor ligand [I-123]iomazenil in healthy human subjects. Psychiatry Res Neuroimaging 45:67, 1992.
    • (1992) Psychiatry Res Neuroimaging , vol.45 , pp. 67
    • Woods, S.W.1    Seibyl, J.P.2    Goddard, A.W.3
  • 17
    • 0028158841 scopus 로고
    • SPECT measurement of benzodiazepine receptors in human brain with iodine-123-iomazenil: Kinetic and equilibrium paradigms
    • Abi-Dargham A, Laurelle M, Seibyl J, et al: SPECT measurement of benzodiazepine receptors in human brain with iodine-123-iomazenil: Kinetic and equilibrium paradigms. J Nucl Med 35:228, 1994.
    • (1994) J Nucl Med , vol.35 , pp. 228
    • Abi-Dargham, A.1    Laurelle, M.2    Seibyl, J.3
  • 18
    • 0028855340 scopus 로고
    • Reproducibility of SPECT measurement of benzodiazepine receptors in human brain with iodinc-123-iomazcnil
    • Abi-Dargham A, Gandelman M, Zoghbi SS, et al: Reproducibility of SPECT measurement of benzodiazepine receptors in human brain with iodinc-123-iomazcnil. J Nucl Med 36:167, 1995.
    • (1995) J Nucl Med , vol.36 , pp. 167
    • Abi-Dargham, A.1    Gandelman, M.2    Zoghbi, S.S.3
  • 19
    • 0029796805 scopus 로고    scopus 로고
    • Preliminary evaluation of distribution volume for 123-I-iomazenil in Alzheimer's disease as a measure of loss of synapses
    • Soricelli A, Postiglione A, Grivet-Fojaia MR, et al: Preliminary evaluation of distribution volume for 123-I-iomazenil in Alzheimer's disease as a measure of loss of synapses. Eur J Nucl Med 23:1323, 1996.
    • (1996) Eur J Nucl Med , vol.23 , pp. 1323
    • Soricelli, A.1    Postiglione, A.2    Grivet-Fojaia, M.R.3
  • 20
    • 0030967717 scopus 로고    scopus 로고
    • Comparison of iodine-123-iomazenil SPECT and technetium-99m-HMPAO-SPECT in Alzheimer's disease
    • Fukuchi K, Hashikawa K, Seike Y, et al: Comparison of iodine-123-iomazenil SPECT and technetium-99m-HMPAO-SPECT in Alzheimer's disease. J Nucl Med 38:467, 1997.
    • (1997) J Nucl Med , vol.38 , pp. 467
    • Fukuchi, K.1    Hashikawa, K.2    Seike, Y.3
  • 21
    • 0029039009 scopus 로고
    • Simple quantification of benzodiazepine receptor binding and ligand transport using iodine-123-iomazenil and two SPECT scans
    • Onishi Y, Yonekura Y, Takao M, et al: Simple quantification of benzodiazepine receptor binding and ligand transport using iodine-123-iomazenil and two SPECT scans. J Nucl Med 36: 1201, 1995.
    • (1995) J Nucl Med , vol.36 , pp. 1201
    • Onishi, Y.1    Yonekura, Y.2    Takao, M.3
  • 22
    • 0029914546 scopus 로고    scopus 로고
    • Noninvasive quantification of iodine-123-iomazenil SPECT
    • Onishi Y, Yonekura Y, Nishizawa S, et al: Noninvasive quantification of iodine-123-iomazenil SPECT. J Nucl Med 37:374, 1996.
    • (1996) J Nucl Med , vol.37 , pp. 374
    • Onishi, Y.1    Yonekura, Y.2    Nishizawa, S.3
  • 23
    • 0021271971 scopus 로고
    • Clinical diagnosis of Alzheimer's disease: Report of the NINCDS-ADRDA work group under the auspices of department of health and human services task force on Alzheimer's disease
    • McKhann G, Drachman D, Folstein M, et al: Clinical diagnosis of Alzheimer's disease: Report of the NINCDS-ADRDA Work Group under the auspices of Department of Health and Human Services Task Force on Alzheimer's Disease. Neurology 34:939, 1984.
    • (1984) Neurology , vol.34 , pp. 939
    • McKhann, G.1    Drachman, D.2    Folstein, M.3
  • 25
    • 0019967975 scopus 로고
    • The global deterioration scale for assessment of primary degenerative dementia
    • Reisberg B, Ferris SH, de Leon MJ, Crook T: The global deterioration scale for assessment of primary degenerative dementia. Am J Psychiatry 139:1136, 1982.
    • (1982) Am J Psychiatry , vol.139 , pp. 1136
    • Reisberg, B.1    Ferris, S.H.2    De Leon, M.J.3    Crook, T.4
  • 26
    • 0016823810 scopus 로고
    • Mini-mental state: A pratical method for grading the cognitive state of patients for the clinician
    • Folstein MF, Folstein SE, McHugh PR: Mini-mental state: A pratical method for grading the cognitive state of patients for the clinician. J Psychiatr Res 12:189, 1975.
    • (1975) J Psychiatr Res , vol.12 , pp. 189
    • Folstein, M.F.1    Folstein, S.E.2    McHugh, P.R.3
  • 27
    • 84935513944 scopus 로고
    • The development of ASPECT, an annular single crystal brain camera for high efficiency SPECT
    • Genna S, Smith AP: The development of ASPECT, an annular single crystal brain camera for high efficiency SPECT. IEEE Trans Nucl Sci 35:654, 1988.
    • (1988) IEEE Trans Nucl Sci , vol.35 , pp. 654
    • Genna, S.1    Smith, A.P.2
  • 28
    • 0017452940 scopus 로고
    • A method for attenuation correction in radionuclide computed tomography
    • Chang L-T: A method for attenuation correction in radionuclide computed tomography. IEEE Trans Nucl Sci 25:638, 1978.
    • (1978) IEEE Trans Nucl Sci , vol.25 , pp. 638
    • Chang, L.-T.1
  • 29
    • 0024242589 scopus 로고
    • The retention of [Tc-99m]-d,l,-HMPAO in the human brain after intracarotid bolus injection: A kinetic analysis
    • Lassen NA, Andersen AR, Friberg L, Paulson OB: The retention of [Tc-99m]-d,l,-HMPAO in the human brain after intracarotid bolus injection: A kinetic analysis. J Cereb Blood Flow Metab 8:S13, 1988.
    • (1988) J Cereb Blood Flow Metab , vol.8
    • Lassen, N.A.1    Andersen, A.R.2    Friberg, L.3    Paulson, O.B.4
  • 30
    • 0024231146 scopus 로고
    • The retention mechanism of technetium-99m-HMPAO: Intracellular reaction with glutathione
    • Neirinckx RD, Burke JF, Harrison RC, et al: The retention mechanism of technetium-99m-HMPAO: Intracellular reaction with glutathione. J Cereb Blood Flow Metab 8:S4 1988.
    • (1988) J Cereb Blood Flow Metab , vol.8
    • Neirinckx, R.D.1    Burke, J.F.2    Harrison, R.C.3
  • 31
    • 0029833654 scopus 로고    scopus 로고
    • Comparison of technetium-99m-HMPAO and Xenon-133 measurements of regional cerebral blood flow by SPECT
    • Payne JK, Trivedi MH, Devous MD: Comparison of technetium-99m-HMPAO and Xenon-133 measurements of regional cerebral blood flow by SPECT. J Nucl Med 37:1735, 1996.
    • (1996) J Nucl Med , vol.37 , pp. 1735
    • Payne, J.K.1    Trivedi, M.H.2    Devous, M.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.