Ultrasound biomicroscopy examination of intraocular lens haptic position after phacoemulsification with continuous curvilinear capsulorhexis and extracapsular cataract extraction with linear capsulotomy

Author keywords

Continuous curvilinear capsulorhexis; Extracapsular cataract extraction; Intraocular lens position; Linear capsulotomy; Phacoemulsification; Ultrasound biomicroscopy

Indexed keywords

AGED; ANTERIOR EYE CHAMBER ANGLE; ARTICLE; BIOMICROSCOPY; CAPSULORHEXIS; CAPSULOTOMY; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; EXTRACAPSULAR CATARACT EXTRACTION; FEMALE; HUMAN; IRIS; LASER FLARE CELL METER; LENS CAPSULE; LENS IMPLANT; MALE; PHACOEMULSIFICATION; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; SENSORY ORGAN INFLAMMATION; SLIT LAMP; STATISTICAL ANALYSIS; THICKNESS; VISUAL STIMULATION;

EID: 0032813455     PISSN: 13953907     EISSN: None     Source Type: Journal    
DOI: 10.1034/j.1600-0420.1999.770406.x     Document Type: Article
Times cited : (31)

References (9)
  • 2
    • 0025349162 scopus 로고
    • The round capsulorhexis capsulotomy and the rationale for 11.0 mm diameter IOL
    • Blumenthal M, Assia E & Neumann D (1990): The round capsulorhexis capsulotomy and the rationale for 11.0 mm diameter IOL. Eur J Implant Refract Surg 2: 15-19.
    • (1990) Eur J Implant Refract Surg , vol.2 , pp. 15-19
    • Blumenthal, M.1    Assia, E.2    Neumann, D.3
  • 3
    • 0031905457 scopus 로고    scopus 로고
    • Phacoemulsification and lens implantation in rabbit eyes: Capsular bag versus ciliary sulcus implantation and 4.0 versus 7.0 mm capsulorhexis
    • Laurell C-G, Zetterström C & Lundgren B (1998). Phacoemulsification and lens implantation in rabbit eyes: Capsular bag versus ciliary sulcus implantation and 4.0 versus 7.0 mm capsulorhexis. J Cataract Refract Surg 24: 230-236.
    • (1998) J Cataract Refract Surg , vol.24 , pp. 230-236
    • Laurell, C.-G.1    Zetterström, C.2    Lundgren, B.3
  • 4
    • 0031728104 scopus 로고    scopus 로고
    • Randomized study of the blood-aqueous barrier reaction after phacoemulsification and extracapsular cataract extraction
    • Laurell C-G, Zetterström C, Philipson B & Syrén-Nordquist S (1998): Randomized study of the blood-aqueous barrier reaction after phacoemulsification and extracapsular cataract extraction. Acta Ophthalmologica Scandinavica 76: 573-578.
    • (1998) Acta Ophthalmologica Scandinavica , vol.76 , pp. 573-578
    • Laurell, C.-G.1    Zetterström, C.2    Philipson, B.3    Syrén-Nordquist, S.4
  • 5
    • 0022517132 scopus 로고
    • Pseudophakic posterior iris chafing syndrome
    • Masket S (1986): Pseudophakic posterior iris chafing syndrome. J Cataract Refract Surg 12: 252-256.
    • (1986) J Cataract Refract Surg , vol.12 , pp. 252-256
    • Masket, S.1
  • 7
    • 0028348655 scopus 로고
    • Ultrasound biomicroscopic analysis of haptic position in late-onset, recurrent hyphema after posterior chamber lens implantation
    • Pavlin CJ, Harasiewicz K, Eng P & Foster FS (1994): Ultrasound biomicroscopic analysis of haptic position in late-onset, recurrent hyphema after posterior chamber lens implantation. J. Cataract Refract. Surg. 20: 182-5.
    • (1994) J. Cataract Refract. Surg. , vol.20 , pp. 182-185
    • Pavlin, C.J.1    Harasiewicz, K.2    Eng, P.3    Foster, F.S.4
  • 9
    • 0026552857 scopus 로고
    • Ultrasound biomicroscopy analysis of the anterior segment in normal and glaucomatous eyes
    • Pavlin CJ, Harasiewicz K & Foster FS (1992): Ultrasound biomicroscopy analysis of the anterior segment in normal and glaucomatous eyes. Am J Ophthalmol 113: 381-389.
    • (1992) Am J Ophthalmol , vol.113 , pp. 381-389
    • Pavlin, C.J.1    Harasiewicz, K.2    Foster, F.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.