Volumn 84, Issue 1-4, 1999, Pages 375-380

An active personal dosemeter/spectrometer for neutrons

Author keywords

[No Author keywords available]

Indexed keywords

SILICON;

EID: 0032812737     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.rpd.a032760     Document Type: Conference Paper
Times cited : (11)

References (14)
  • 2
    • 0030894191 scopus 로고    scopus 로고
    • Single Diode Detector for Individual Neutron Dosimetry Using a Pulse Shape Analysis
    • Bordy, J. M., Lahaye, T., Landre, F., Hoflack, C., Lequin, S. and Barthe, J. Single Diode Detector for Individual Neutron Dosimetry Using a Pulse Shape Analysis. Radiat. Prot. Dosim. 70, 73-78 (1997).
    • (1997) Radiat. Prot. Dosim. , vol.70 , pp. 73-78
    • Bordy, J.M.1    Lahaye, T.2    Landre, F.3    Hoflack, C.4    Lequin, S.5    Barthe, J.6
  • 4
    • 0344871881 scopus 로고
    • A Combined Real Time Wide Energy Neutron Dosimeter and Survey Meter for High Neutron Dose Rates with Si Surface Barrier Detectors
    • Eisen, Y., Engler, G., Ovadia, E. and Shamai, Y. A Combined Real Time Wide Energy Neutron Dosimeter and Survey Meter for High Neutron Dose Rates with Si Surface Barrier Detectors. Nucl. Instrum. Methods 211, 171-178 (1983).
    • (1983) Nucl. Instrum. Methods , vol.211 , pp. 171-178
    • Eisen, Y.1    Engler, G.2    Ovadia, E.3    Shamai, Y.4
  • 5
    • 0000899868 scopus 로고
    • PTB Neutron Fields for the Calibration of Neutron Sensitive Devices
    • Köln: TÜV Rheinland GmbH
    • Guldbakke, S., Dietz, E., Kluge, H. and Schlegel, D. PTB Neutron Fields for the Calibration of Neutron Sensitive Devices. In: Strahlenschutz: Physik und Meßtechnik. (Köln: TÜV Rheinland GmbH) pp. 240-247 (1994).
    • (1994) Strahlenschutz: Physik und Meßtechnik , pp. 240-247
    • Guldbakke, S.1    Dietz, E.2    Kluge, H.3    Schlegel, D.4
  • 9
    • 0025907009 scopus 로고
    • The Calibration of Secondary Standard Ionisation Chambers in High Energy Photon Fields
    • Guldbakke, S., Rossiter, M. J., Schäffler, D. and Williams, T. T. The Calibration of Secondary Standard Ionisation Chambers in High Energy Photon Fields. Radiat. Prot. Dosim. 35, 237-240 (1991).
    • (1991) Radiat. Prot. Dosim. , vol.35 , pp. 237-240
    • Guldbakke, S.1    Rossiter, M.J.2    Schäffler, D.3    Williams, T.T.4
  • 10
    • 0030334747 scopus 로고    scopus 로고
    • Conversion Coefficients for Use in Radiological Protection against External Radiation
    • ICRP Publication 74
    • International Commission on Radiation Protection. Conversion Coefficients for Use in Radiological Protection against External Radiation. ICRP Publication 74. Ann. ICRP 26 (3/4) (1996).
    • (1996) Ann. ICRP , vol.26 , Issue.3-4
  • 12
    • 0031343931 scopus 로고    scopus 로고
    • Neutron Spectrometry with CR-39 Track Detectors and Silicon Diodes Using Unfolding Techniques
    • Luszik-Bhadra, M., Dietz, E., d'Errico, F., Guldbakke, S. and Matzke, M. Neutron Spectrometry with CR-39 Track Detectors and Silicon Diodes Using Unfolding Techniques. Radiat. Meas. 28, 473-478 (1997).
    • (1997) Radiat. Meas. , vol.28 , pp. 473-478
    • Luszik-Bhadra, M.1    Dietz, E.2    D'Errico, F.3    Guldbakke, S.4    Matzke, M.5
  • 13
    • 0003842011 scopus 로고
    • Unfolding of Pulse Height Spectra: The HEPRO Program System
    • Braunschweig: PTB
    • Matzke, M. Unfolding of Pulse Height Spectra: The HEPRO Program System. PTB report PTB-N-19 (Braunschweig: PTB) (1994).
    • (1994) PTB Report PTB-N-19
    • Matzke, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.