메뉴 건너뛰기




Volumn 20, Issue 6, 1999, Pages 875-887

Nested designs in ruggedness testing

Author keywords

Nested designs; Ruggedness test

Indexed keywords

TETRACYCLINE;

EID: 0032808729     PISSN: 07317085     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0731-7085(99)00112-0     Document Type: Article
Times cited : (27)

References (19)
  • 1
    • 0345712741 scopus 로고
    • The National Formulary XVII, United States Pharmacopeial Convention, Rockville, MD and 1712.
    • The United States Pharmacopeia XXII, The National Formulary XVII, United States Pharmacopeial Convention, Rockville, MD, 1990, p. 1337 and 1712.
    • (1990) The United States Pharmacopeia , vol.22 , pp. 1337
  • 2
    • 0343071330 scopus 로고
    • The National Formulary XVIII, United States Pharmacopeial Convention, Rockville, MD
    • The United States Pharmacopeia 23, The National Formulary XVIII, United States Pharmacopeial Convention, Rockville, MD, 1995, p. 1510.
    • (1995) The United States Pharmacopeia , vol.23 , pp. 1510
  • 4
    • 0001131698 scopus 로고
    • The design of optimum multifactorial experiments
    • Plackett R.L., Burman J.P. The design of optimum multifactorial experiments. Biometrika. 33:1946;305-325.
    • (1946) Biometrika , vol.33 , pp. 305-325
    • Plackett, R.L.1    Burman, J.P.2
  • 7
    • 0031738199 scopus 로고    scopus 로고
    • Ruggedness testing of chromatographic methods: Selection of factors and levels
    • Vander Heyden Y., Questier F., Massart D.L. Ruggedness testing of chromatographic methods: selection of factors and levels. J. Pharm. Biomed. Anal. 18:1998;43-56.
    • (1998) J. Pharm. Biomed. Anal. , vol.18 , pp. 43-56
    • Vander Heyden, Y.1    Questier, F.2    Massart, D.L.3
  • 9
    • 0003515157 scopus 로고
    • Accuracy (trueness and precision) of measurements methods and results
    • ISO, International Organization for Standardization International Standard ISO/DIS 5725-3
    • ISO, International Organization for Standardization, Accuracy (trueness and precision) of measurements methods and results. Part 3: Intermediate measures of the precision of a standard measurement method, International Standard ISO/DIS 5725-3, 1994.
    • (1994) Part 3: Intermediate Measures of the Precision of a Standard Measurement Method
  • 10
    • 0029143805 scopus 로고
    • Ruggedness tests on the HPLC assay of the United States Pharmacopeia XXII for tetracycline hydrochloride. A comparison of experimental designs and statistical interpretations
    • Vander Heyden Y., Luypaert K., Hartmann C., Massart D.L., Hoogmartens J., De Beer J. Ruggedness tests on the HPLC assay of the United States Pharmacopeia XXII for tetracycline hydrochloride. A comparison of experimental designs and statistical interpretations. Anal. Chim. Acta. 312:1995;245-262.
    • (1995) Anal. Chim. Acta , vol.312 , pp. 245-262
    • Vander Heyden, Y.1    Luypaert, K.2    Hartmann, C.3    Massart, D.L.4    Hoogmartens, J.5    De Beer, J.6
  • 11
    • 0028846756 scopus 로고
    • Ruggedness tests on an HPLC assay: Comparison of tests at two and three levels by using two-level Plackett-Burman designs
    • Vander Heyden Y., Hartmann C., Massart D.L., Michel L., Kiechle P., Erni F. Ruggedness tests on an HPLC assay: comparison of tests at two and three levels by using two-level Plackett-Burman designs. Anal. Chim. Acta. 316:1995;15-26.
    • (1995) Anal. Chim. Acta , vol.316 , pp. 15-26
    • Vander Heyden, Y.1    Hartmann, C.2    Massart, D.L.3    Michel, L.4    Kiechle, P.5    Erni, F.6
  • 14
    • 0003510032 scopus 로고    scopus 로고
    • Statgraphics® Plus, by Statistical Graphics Corporation, version 6, Manugistics Inc., Rockville, USA.
    • Statgraphics® Plus, Statistical Graphics System by Statistical Graphics Corporation, version 6, Manugistics Inc., Rockville, USA.
    • Statistical Graphics System
  • 16
    • 0030753997 scopus 로고    scopus 로고
    • Influence of the sequence of experiments in a ruggedness test when drift occurs
    • Vander Heyden Y., Bourgeois A., Massart D.L. Influence of the sequence of experiments in a ruggedness test when drift occurs. Anal. Chim. Acta. 347:1997;369-384.
    • (1997) Anal. Chim. Acta , vol.347 , pp. 369-384
    • Vander Heyden, Y.1    Bourgeois, A.2    Massart, D.L.3
  • 17
    • 0032080894 scopus 로고    scopus 로고
    • A ruggedness test strategy for procedure related factors: Experimental set-up and interpretation
    • Vander Heyden Y., Questier F., Massart D.L. A ruggedness test strategy for procedure related factors: experimental set-up and interpretation. J. Pharm. Biomed. Anal. 17:1998;153-168.
    • (1998) J. Pharm. Biomed. Anal. , vol.17 , pp. 153-168
    • Vander Heyden, Y.1    Questier, F.2    Massart, D.L.3
  • 18
    • 84946641055 scopus 로고
    • Symmetrical and asymmetrical fractional factorial plans
    • Addelman S. Symmetrical and asymmetrical fractional factorial plans. Technometrics. 4:1962;21-46.
    • (1962) Technometrics , vol.4 , pp. 21-46
    • Addelman, S.1
  • 19
    • 0027323147 scopus 로고
    • Influence of experimental parameters on the microencapsulation of a photopolymerizable phase
    • Pernot J.M., Brun H., Pouyet B., Sergent M., Phan-Tan-Luu R. Influence of experimental parameters on the microencapsulation of a photopolymerizable phase. J. Microencapsulation. 10(3):1993;323-328.
    • (1993) J. Microencapsulation , vol.10 , Issue.3 , pp. 323-328
    • Pernot, J.M.1    Brun, H.2    Pouyet, B.3    Sergent, M.4    Phan-Tan-Luu, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.