Volumn 4, Issue 1, 1999, Pages 45-52

Determination of accuracies of 10 models of home blood pressure monitors using an oscillometric simulator

Author keywords

Association for the Advancement of Medical Instrumentation; Blood pressure; British Hypertension Society; Home blood pressure devices; Self care; Standards; Validation

Indexed keywords

ACCURACY; ARTICLE; BLOOD PRESSURE MONITORING; BLOOD PRESSURE REGULATION; DIASTOLIC BLOOD PRESSURE; HYPERTENSION; MEDICAL INSTRUMENTATION; OSCILLOMETRY; PRIORITY JOURNAL; RELIABILITY; REPRODUCIBILITY; SIMULATOR; SYSTOLIC BLOOD PRESSURE;

EID: 0032806757     PISSN: 13595237     EISSN: None     Source Type: Journal    
DOI: 10.1097/00126097-199904010-00007     Document Type: Article
Times cited : (16)

References (17)
  • 1
    • 0031434311 scopus 로고    scopus 로고
    • Substitution of simulators for human subjects
    • Mieke S. Substitution of simulators for human subjects. Blood Press Monit 1997; 2:251-256.
    • (1997) Blood Press Monit , vol.2 , pp. 251-256
    • Mieke, S.1
  • 2
    • 0009612890 scopus 로고    scopus 로고
    • January
    • http://www.fda.gov/cdrh/ode/noninvas.html, January 1997.
    • (1997)
  • 3
    • 0003556396 scopus 로고
    • Arlington, VA: American National Standards Institute
    • Association for the Advancement of Medical Instrumentation. Electronic or automated sphygmomanometers. Arlington, VA: American National Standards Institute; 1992. pp. 1-40.
    • (1992) Electronic or Automated Sphygmomanometers , pp. 1-40
  • 4
    • 0025071770 scopus 로고
    • The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems
    • O'Brien E, Petrie J, Littler W, De Swiet M, Padfield PL, O'Malley K, et al. The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems. J Hypertens 1990; 8:607-619.
    • (1990) J Hypertens , vol.8 , pp. 607-619
    • O'Brien, E.1    Petrie, J.2    Littler, W.3    De Swiet, M.4    Padfield, P.L.5    O'Malley, K.6
  • 5
    • 0027218269 scopus 로고
    • An outline of the revised British Hypertension Society protocol for the evaluation of blood pressure measuring devices [short report]
    • O'Brien E, Petrie J, Littler W, De Swiet M, Padfield PL, Altman DG, et al. An outline of the revised British Hypertension Society protocol for the evaluation of blood pressure measuring devices [short report]. J Hypertens 1993; 11:677-679.
    • (1993) J Hypertens , vol.11 , pp. 677-679
    • O'Brien, E.1    Petrie, J.2    Littler, W.3    De Swiet, M.4    Padfield, P.L.5    Altman, D.G.6
  • 6
    • 0009642016 scopus 로고    scopus 로고
    • http://www.nist.gov/
  • 7
    • 0030203789 scopus 로고    scopus 로고
    • Comparison of the Omron HEM-713C automated blood pressure monitor with a standard auscultatory method using a mercury manometer
    • Mufunda J, Sparks B, Chifamba J, Dakwa C, Matenga JA, Adams JM, et al. Comparison of the Omron HEM-713C automated blood pressure monitor with a standard auscultatory method using a mercury manometer. Central African J Med 1996; 42:230-232.
    • (1996) Central African J Med , vol.42 , pp. 230-232
    • Mufunda, J.1    Sparks, B.2    Chifamba, J.3    Dakwa, C.4    Matenga, J.A.5    Adams, J.M.6
  • 8
    • 0029364662 scopus 로고
    • Accuracy of an oscillometric automatic blood pressure device: The Omron HEM403C
    • O'Brien E, Atkins N. Accuracy of an oscillometric automatic blood pressure device: the Omron HEM403C. J Hum Hypertens 1995; 9:781-783.
    • (1995) J Hum Hypertens , vol.9 , pp. 781-783
    • O'Brien, E.1    Atkins, N.2
  • 10
    • 1842426223 scopus 로고    scopus 로고
    • Evaluation of three devices for self-measurement of blood pressure according to the revised British Hypertension Society Protocol: The Omron HEM-705CP, Philips HP5332, and Nissei DS-175
    • O'Brien E, Mee F, Atkins N, Thomas M. Evaluation of three devices for self-measurement of blood pressure according to the revised British Hypertension Society Protocol: the Omron HEM-705CP, Philips HP5332, and Nissei DS-175. Blood Press Monit 1996; 1:55-61.
    • (1996) Blood Press Monit , vol.1 , pp. 55-61
    • O'Brien, E.1    Mee, F.2    Atkins, N.3    Thomas, M.4
  • 11
    • 0028101528 scopus 로고
    • Accuracy of the Omron HEM 706 portable monitor for home measurement of blood pressure
    • Foster C, McKinlay S, Cruickshank JM, Coats AJ. Accuracy of the Omron HEM 706 portable monitor for home measurement of blood pressure. J Hum Hypertens 1994; 8:661-664.
    • (1994) J Hum Hypertens , vol.8 , pp. 661-664
    • Foster, C.1    McKinlay, S.2    Cruickshank, J.M.3    Coats, A.J.4
  • 13
    • 16044368606 scopus 로고    scopus 로고
    • Deutsches Institut für Normung. Ptorzheim: Deutsches Institut für Normung
    • Deutsches Institut für Normung. Nichtinvasive Blutdruckmegßerǎte-Klinische Prüfung. Ptorzheim: Deutsches Institut für Normung; 1996.
    • (1996) Nichtinvasive Blutdruckmegßerǎte-Klinische Prüfung
  • 14
    • 0031847323 scopus 로고    scopus 로고
    • Validation of an oscillometric electronic sphygmomanometer in an obstetric population
    • Kwek K, Chan YGS, Tan KH, Yeo GSH: Validation of an oscillometric electronic sphygmomanometer in an obstetric population. Am J Hypertens 1998; 11:978-982.
    • (1998) Am J Hypertens , vol.11 , pp. 978-982
    • Kwek, K.1    Chan, Y.G.S.2    Tan, K.H.3    Yeo, G.S.H.4
  • 15
    • 0009561379 scopus 로고    scopus 로고
    • Personal communication from Osamu Shirasaki, Omron Healthcare, Inc., Director of Technology
    • Personal communication from Osamu Shirasaki, Omron Healthcare, Inc., Director of Technology 1998.
    • (1998)
  • 16
    • 0031464019 scopus 로고    scopus 로고
    • Considerations for simulation-based evaluation of noninvasive blood pressure monitors
    • Ng K. Considerations for simulation-based evaluation of noninvasive blood pressure monitors. Blood Press Monit 1997; 2:257-268.
    • (1997) Blood Press Monit , vol.2 , pp. 257-268
    • Ng, K.1
  • 17
    • 0031088983 scopus 로고    scopus 로고
    • An evaluation of three oscillometric non-invasive blood pressure simulators
    • Amoore JN, Geake WB. An evaluation of three oscillometric non-invasive blood pressure simulators. J Clin Eng 1997; 22:93-100.
    • (1997) J Clin Eng , vol.22 , pp. 93-100
    • Amoore, J.N.1    Geake, W.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.