메뉴 건너뛰기




Volumn 17, Issue 12, 1999, Pages 1210-1213

Optical tracking and detection of immunomagnetically selected and aligned cells

Author keywords

Cell analysis; Compact disk player; Cytometry; Ferrofluids; Ferromagnetic nanoparticles

Indexed keywords

FERROMAGNETIC MATERIAL;

EID: 0032804666     PISSN: 10870156     EISSN: None     Source Type: Journal    
DOI: 10.1038/70761     Document Type: Article
Times cited : (106)

References (11)
  • 1
    • 0001194259 scopus 로고
    • High speed automatic blood cell counter and cell size analyzer
    • Coulter, W.H. High speed automatic blood cell counter and cell size analyzer. Proc. Watt Electronics Conf. 12, 1034 (1956).
    • (1956) Proc. Watt Electronics Conf. , vol.12 , pp. 1034
    • Coulter, W.H.1
  • 3
    • 0025778621 scopus 로고
    • Microscope-based multiparameter laser scanning cytometry yielding data comparable to flow cytometry
    • Kamentsky, L.A. & Kamentsky, L.D. Microscope-based multiparameter laser scanning cytometry yielding data comparable to flow cytometry. Cytometry 12, 381-387 (1991).
    • (1991) Cytometry , vol.12 , pp. 381-387
    • Kamentsky, L.A.1    Kamentsky, L.D.2
  • 4
    • 0021943353 scopus 로고
    • The Cytodisk: A cytometer based upon a new principle of cell alignment
    • de Grooth, B.G., Geerken, T.H. & Greve, J. The Cytodisk: a cytometer based upon a new principle of cell alignment. Cytometry 6, 226-233 (1985).
    • (1985) Cytometry , vol.6 , pp. 226-233
    • De Grooth, B.G.1    Geerken, T.H.2    Greve, J.3
  • 5
    • 0029883533 scopus 로고    scopus 로고
    • Volumetric capillary cytometry: A new method for absolute cell enumeration
    • Dietz, L.J, Dubrow, R.S., Manian, B.S. & Sizto, N.L. Volumetric capillary cytometry: a new method for absolute cell enumeration. Cytometry 23, 177-186 (1996).
    • (1996) Cytometry , vol.23 , pp. 177-186
    • Dietz, L.J.1    Dubrow, R.S.2    Manian, B.S.3    Sizto, N.L.4
  • 8
    • 0012058975 scopus 로고    scopus 로고
    • (eds Kishimoto T. et al.) Garland Publishing Inc. New York
    • Sewell, W.A., Cooley, M.A. & Hegen, M. in Leucocyte typing VI (eds Kishimoto T. et al.) 499-502 (Garland Publishing Inc. New York, 1997).
    • (1997) Leucocyte Typing VI , pp. 499-502
    • Sewell, W.A.1    Cooley, M.A.2    Hegen, M.3
  • 9
    • 77951342776 scopus 로고
    • Die Fluorochromierung mit Acridinorange, eine Methode zur Lebendbeobachtung gefarbter Blutzellen
    • Kosenow, W. Die Fluorochromierung mit Acridinorange, eine Methode zur Lebendbeobachtung gefarbter Blutzellen. Acta Haematol. 7, 217 (1952).
    • (1952) Acta Haematol. , vol.7 , pp. 217
    • Kosenow, W.1
  • 10
    • 0022614141 scopus 로고
    • Flow cytometry of DNA content using Oxazine 750 or related laser dyes with 633 nm excitation
    • Shapiro, H.M. & Stephens, S. Flow cytometry of DNA content using Oxazine 750 or related laser dyes with 633 nm excitation. Cytometry 7, 107-110 (1986).
    • (1986) Cytometry , vol.7 , pp. 107-110
    • Shapiro, H.M.1    Stephens, S.2
  • 11
    • 17444403622 scopus 로고    scopus 로고
    • Tom Bakker Schut
    • http://www.bio.umass.edij/mcbfacs/flowcat.htmlSanalyse, Tom Bakker Schut.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.