Volumn 19, Issue 4, 1999, Pages 321-328

Simple forced oscillatory technique and spirometry in assessment of bronchial responsiveness in non-asthmatic and asthmatic subjects

Author keywords

Airway responsiveness; Asthma; Healthy subjects; Oscillatory resistance; Spirometry

Indexed keywords

METHACHOLINE;

EID: 0032803119     PISSN: 01445979     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1365-2281.1999.00187.x     Document Type: Article
Times cited : (4)

References (22)
  • 1
    • 0000600203 scopus 로고
    • Guidelines for diagnosis and treatment of asthma
    • AMERICAN THORACIC SOCIETY. (1987) Guidelines for diagnosis and treatment of asthma. Am Rev Respir Dis, 136, 225-244.
    • (1987) Am Rev Respir Dis , vol.136 , pp. 225-244
  • 3
    • 0028300123 scopus 로고
    • Comparative evaluation of devices used for measurement of respiratory input impedance in different centres
    • BRUSASCO V., SCHIAVI E., BASANO L., et al. (1994) Comparative evaluation of devices used for measurement of respiratory input impedance in different centres. Eur Respir Rev, 4 (19), 118-120.
    • (1994) Eur Respir Rev , vol.4 , Issue.19 , pp. 118-120
    • Brusasco, V.1    Schiavi, E.2    Basano, L.3
  • 4
    • 0023680847 scopus 로고
    • Comparison of the dose-response curves obtained by forced oscillation and plethysmography during carbachol inhalation
    • CHINET T., PELLE G., MACQUIN-MAVIER I., et al. (1988) Comparison of the dose-response curves obtained by forced oscillation and plethysmography during carbachol inhalation. Eur Respir J, 1, 600-605.
    • (1988) Eur Respir J , vol.1 , pp. 600-605
    • Chinet, T.1    Pelle, G.2    Macquin-Mavier, I.3
  • 5
    • 0344957938 scopus 로고
    • Specificity and sensitivity of various parameters of dose-response curves
    • EISER N. (1991) Specificity and sensitivity of various parameters of dose-response curves. Eur Respir Rev, 1, 41-47.
    • (1991) Eur Respir Rev , vol.1 , pp. 41-47
    • Eiser, N.1
  • 6
    • 0027402790 scopus 로고
    • Standardized lung function testing
    • EUROPEAN RESPIRATORY SOCIETY (1993) Standardized lung function testing. Eur Respir J, 6 (Suppl. 16).
    • (1993) Eur Respir J , vol.6 , Issue.16 SUPPL.
  • 7
    • 0028198455 scopus 로고
    • Monitoring respiratory impedance by forced oscillation in mechanically-ventilated patients
    • NAVAJAS D., FARRĖ R., ROTGER M., et al. (1994) Monitoring respiratory impedance by forced oscillation in mechanically-ventilated patients. Eur Respir Rev, 4 (19), 216-218.
    • (1994) Eur Respir Rev , vol.4 , Issue.19 , pp. 216-218
    • Navajas, D.1    Farre, R.2    Rotger, M.3
  • 8
    • 0024316427 scopus 로고
    • The repeatability and validity of respiratory resistance measured by the forced oscillation technique
    • NEILD J. E., TWORT C. H., CHINN S., et al. (1989) The repeatability and validity of respiratory resistance measured by the forced oscillation technique. Respir Med, 83, 111-118.
    • (1989) Respir Med , vol.83 , pp. 111-118
    • Neild, J.E.1    Twort, C.H.2    Chinn, S.3
  • 9
    • 0023641171 scopus 로고
    • Aerosol deposition in automatic dosimeter nebulisation
    • NIEMINEN M. M., HOLLI H., LAHDENSUO A., et al. (1987) Aerosol deposition in automatic dosimeter nebulisation. Eur J Respir Dis, 71, 145-152.
    • (1987) Eur J Respir Dis , vol.71 , pp. 145-152
    • Nieminen, M.M.1    Holli, H.2    Lahdensuo, A.3
  • 10
    • 0023518519 scopus 로고
    • Total respiratory resistance and reactance in patients with upper airway obstruction
    • VAN NOORD J. A., WELLENS W., CLARYSSE I., et al. (1987) Total respiratory resistance and reactance in patients with upper airway obstruction. Chest, 92, 475-480.
    • (1987) Chest , vol.92 , pp. 475-480
    • Van Noord, J.A.1    Wellens, W.2    Clarysse, I.3
  • 11
    • 0024563401 scopus 로고
    • Total respiratory resistance and reactance as a measurement of response to bronchial challenge with histamine
    • VAN NOORD J. A., CLEMENT J., VAN DE WOESTIJNE K. P., et al. (1989) Total respiratory resistance and reactance as a measurement of response to bronchial challenge with histamine. Am Rev Respir Dis, 139, 921-926.
    • (1989) Am Rev Respir Dis , vol.139 , pp. 921-926
    • Van Noord, J.A.1    Clement, J.2    Van De Woestijne, K.P.3
  • 12
    • 0028226836 scopus 로고
    • Measurement of bronchial responsiveness by forced oscillation technique in occupational epidemiology
    • PAIRON J. C., IWATSUBO Y., HUBERT C., et al. (1994) Measurement of bronchial responsiveness by forced oscillation technique in occupational epidemiology. Eur Respir J, 7, 484-489.
    • (1994) Eur Respir J , vol.7 , pp. 484-489
    • Pairon, J.C.1    Iwatsubo, Y.2    Hubert, C.3
  • 13
    • 0027336888 scopus 로고
    • Respiratory mechanics studied by forced oscillations during artificial ventilation
    • PESLIN R., DA SILVA J. F., DUVIVIER C., et al. (1993) Respiratory mechanics studied by forced oscillations during artificial ventilation. Eur Respir J, 6, 772-784.
    • (1993) Eur Respir J , vol.6 , pp. 772-784
    • Peslin, R.1    Da Silva, J.F.2    Duvivier, C.3
  • 14
    • 0029166118 scopus 로고
    • Comparison of four methods of assessing airflow resistance before and after induced airway narrowing in normal subjects
    • PHAGOO S. B., WATSON R. A., SILVERMAN M., et al. (1995) Comparison of four methods of assessing airflow resistance before and after induced airway narrowing in normal subjects. J Appl Physiol, 79, 518-525.
    • (1995) J Appl Physiol , vol.79 , pp. 518-525
    • Phagoo, S.B.1    Watson, R.A.2    Silverman, M.3
  • 15
    • 6544236423 scopus 로고
    • Ist eine Optimierung der Oszillometrie Möglich?
    • PLEGER E. & FRANK W. (1995) Ist eine Optimierung der Oszillometrie Möglich? Pneumologie, 43, 25-28.
    • (1995) Pneumologie , vol.43 , pp. 25-28
    • Pleger, E.1    Frank, W.2
  • 16
    • 0024396388 scopus 로고
    • Praktische Erfahrungen mit Zwei Oszillatorischen Meßverfahren, Siregnost FD5 und CustoVit, zur Beurteilung Chronischer Atemwegsobstruktionen
    • PLEGER E., WILKE A., GLASER T., et al. (1989) Praktische Erfahrungen mit Zwei Oszillatorischen Meßverfahren, Siregnost FD5 und CustoVit, zur Beurteilung Chronischer Atemwegsobstruktionen. Pneumologie, 43, 353-357.
    • (1989) Pneumologie , vol.43 , pp. 353-357
    • Pleger, E.1    Wilke, A.2    Glaser, T.3
  • 17
    • 0032809067 scopus 로고    scopus 로고
    • Short-term variations in oscillatory and spirometric lung function parameters of non-asthmatic adults
    • RANDELL J. T., SALONEN R. O., PEKKARINEN H. & TUKIAINEN H. (1999) Short-term variations in oscillatory and spirometric lung function parameters of non-asthmatic adults. Clin Physiol, 19, 329-337.
    • (1999) Clin Physiol , vol.19 , pp. 329-337
    • Randell, J.T.1    Salonen, R.O.2    Pekkarinen, H.3    Tukiainen, H.4
  • 18
    • 0024378086 scopus 로고
    • Polyfrequente Oszillatorische Messung des Atemwiderstandes Einschließlich Zugehörigem Phasenwinkel
    • SIMM F. (1989) Polyfrequente Oszillatorische Messung des Atemwiderstandes Einschließlich Zugehörigem Phasenwinkel. Pneumologie, 43, 376-381.
    • (1989) Pneumologie , vol.43 , pp. 376-381
    • Simm, F.1
  • 19
    • 0025860206 scopus 로고
    • Use of an impedance meter for measuring airways responsiveness to histamine
    • SNASHALL P. D., PARKER S., PHIL M., et al. (1991) Use of an impedance meter for measuring airways responsiveness to histamine. Chest, 99, 1183-1185.
    • (1991) Chest , vol.99 , pp. 1183-1185
    • Snashall, P.D.1    Parker, S.2    Phil, M.3
  • 20
    • 0029044587 scopus 로고
    • Bronchial responsiveness to histamine and methacholine measured with forced expirations and with the forced oscillation technique
    • WEERSINK E. J., VAN DE ELSHOUT F. J., VAN HERWAARDEN C., et al. (1995) Bronchial responsiveness to histamine and methacholine measured with forced expirations and with the forced oscillation technique. Respir Med, 89, 351-356.
    • (1995) Respir Med , vol.89 , pp. 351-356
    • Weersink, E.J.1    Van De Elshout, F.J.2    Van Herwaarden, C.3
  • 21
    • 0027467389 scopus 로고
    • Forced oscillation technique and spirometry in cold air provocation tests
    • WESSELING G. J., VANDERHOVEN-AUGUSTIN I. M. & WOUTERS E. F. (1993) Forced oscillation technique and spirometry in cold air provocation tests. Thorax, 48, 254-259.
    • (1993) Thorax , vol.48 , pp. 254-259
    • Wesseling, G.J.1    Vanderhoven-Augustin, I.M.2    Wouters, E.F.3
  • 22
    • 0028330514 scopus 로고
    • Recommendations for measurements of respiratory input impedance by means of the forced oscillatory method
    • VAN DE WOESTIJNE K. P., DESAGER K. N., DUIVERMAN E. J., et al. (1994) Recommendations for measurements of respiratory input impedance by means of the forced oscillatory method. Eur Respir Rev, 4 (19), 235-237.
    • (1994) Eur Respir Rev , vol.4 , Issue.19 , pp. 235-237
    • Van De Woestijne, K.P.1    Desager, K.N.2    Duiverman, E.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.