메뉴 건너뛰기




Volumn 22, Issue 8, 1999, Pages 1154-1156

Intraoperative monitoring is of limited use in routine practice

Author keywords

[No Author keywords available]

Indexed keywords

EVOKED SOMATOSENSORY RESPONSE; NEUROLOGICAL COMPLICATION; NOTE; PARAPLEGIA; PATIENT MONITORING; PRIORITY JOURNAL; SPINAL CORD FUNCTION; SPINAL CORD INJURY; SPINE SURGERY; WAKEFULNESS;

EID: 0032795505     PISSN: 0148639X     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-4598(199908)22:8<1154::AID-MUS25>3.0.CO;2-N     Document Type: Note
Times cited : (3)

References (19)
  • 1
    • 0023789851 scopus 로고
    • Discrepancy between intraoperative SSEP's and postoperative function
    • Chatrian GE, Berger MS, Wirch AL. Discrepancy between intraoperative SSEP's and postoperative function. J Neurosurg 1988;69:450-454.
    • (1988) J Neurosurg , vol.69 , pp. 450-454
    • Chatrian, G.E.1    Berger, M.S.2    Wirch, A.L.3
  • 3
    • 0024434937 scopus 로고
    • Intraoperative monitoring by evoked potentials for spinal cord surgery: the pros
    • Daube JR. Intraoperative monitoring by evoked potentials for spinal cord surgery: the pros. Electroencephalogr Clin Neurophysiol 1989;73;374-377.
    • (1989) Electroencephalogr Clin Neurophysiol , vol.73 , pp. 374-377
    • Daube, J.R.1
  • 4
    • 0026201342 scopus 로고
    • Spinal cord monitoring. Results of the Scoliosis Research Society and the European Spinal Deformity Society Survey
    • Dawson EG, Sherman JE, Kanim LE, Nuwer MR. Spinal cord monitoring. Results of the Scoliosis Research Society and the European Spinal Deformity Society Survey. Spine 1991;16: 361-364.
    • (1991) Spine , vol.16 , pp. 361-364
    • Dawson, E.G.1    Sherman, J.E.2    Kanim, L.E.3    Nuwer, M.R.4
  • 5
    • 0018096546 scopus 로고
    • Intraoperative awakening to monitor spinal cord function during instrumentation and spine fusion
    • Hall JE, Levine CR, Sudhir KG. Intraoperative awakening to monitor spinal cord function during instrumentation and spine fusion. J Bone Jt SurgAm 1978;60:533-536.
    • (1978) J Bone Jt SurgAm , vol.60 , pp. 533-536
    • Hall, J.E.1    Levine, C.R.2    Sudhir, K.G.3
  • 7
    • 0026701526 scopus 로고
    • Neurophysiological evaluation of disorders and procedures affecting the spinal cord and the cauda equina
    • Herdmann J, Dvorak J, Vohanka S. Neurophysiological evaluation of disorders and procedures affecting the spinal cord and the cauda equina. Curr Opin Neurol 1992;5:544-548.
    • (1992) Curr Opin Neurol , vol.5 , pp. 544-548
    • Herdmann, J.1    Dvorak, J.2    Vohanka, S.3
  • 8
    • 0027252829 scopus 로고
    • Magnetic stimulation for monitoring of motor pathways in spinal procedures
    • Herdmann J, Lumenta CB, Huse KO. Magnetic stimulation for monitoring of motor pathways in spinal procedures. Spine 1993;18:551-559.
    • (1993) Spine , vol.18 , pp. 551-559
    • Herdmann, J.1    Lumenta, C.B.2    Huse, K.O.3
  • 9
    • 0008502458 scopus 로고
    • Criteria for detection and pathological significance of response decrement during spinal cord monitoring
    • Ducker TB, Brown RD, editors New York: Springer
    • Jones SJ, Howard L, Shawkat F. Criteria for detection and pathological significance of response decrement during spinal cord monitoring. In: Ducker TB, Brown RD, editors. Neurophysiology and spinal cord monitoring. New York: Springer; 1988. p 201-206.
    • (1988) Neurophysiology and Spinal Cord Monitoring , pp. 201-206
    • Jones, S.J.1    Howard, L.2    Shawkat, F.3
  • 10
    • 0027305709 scopus 로고
    • Use of sciatic neurogenic motor evoked potentials versus spinal potentials to predict early-onset neurologic deficits when intervention is still possible during overdistraction
    • Kai Y, Owen JH, Lenke LG, Bridwell KH, Oakley DM, Sugioka Y. Use of sciatic neurogenic motor evoked potentials versus spinal potentials to predict early-onset neurologic deficits when intervention is still possible during overdistraction. Spine 1993;18:1134-1139.
    • (1993) Spine , vol.18 , pp. 1134-1139
    • Kai, Y.1    Owen, J.H.2    Lenke, L.G.3    Bridwell, K.H.4    Oakley, D.M.5    Sugioka, Y.6
  • 11
    • 0027202310 scopus 로고
    • Spinal cord evoked potential monitoring after spinal cord stimulation during surgery of spinal cord tumors
    • Koyanagi I, Iwasaki Y, Isu T, Abe H, Akino M, Kuroda S. Spinal cord evoked potential monitoring after spinal cord stimulation during surgery of spinal cord tumors. Neurosurgery 1993;33:451-460.
    • (1993) Neurosurgery , vol.33 , pp. 451-460
    • Koyanagi, I.1    Iwasaki, Y.2    Isu, T.3    Abe, H.4    Akino, M.5    Kuroda, S.6
  • 13
    • 0024459072 scopus 로고
    • Variability of somatosensory cortical evoked potential monitoring during spinal surgery
    • Lubicky JP, Spadara JA, Yuan HA, Fredrickson BE, Henderson N. Variability of somatosensory cortical evoked potential monitoring during spinal surgery. Spine 1989;14:790-798.
    • (1989) Spine , vol.14 , pp. 790-798
    • Lubicky, J.P.1    Spadara, J.A.2    Yuan, H.A.3    Fredrickson, B.E.4    Henderson, N.5
  • 14
    • 0016715026 scopus 로고
    • Acute neurological complications in the treatment of scoliosis
    • MacEwen GD, Bunnell WP, Sriram K. Acute neurological complications in the treatment of scoliosis. J Bone Jt Surg 1975;57:404-408.
    • (1975) J Bone Jt Surg , vol.57 , pp. 404-408
    • MacEwen, G.D.1    Bunnell, W.P.2    Sriram, K.3
  • 15
    • 0023814684 scopus 로고
    • Intraoperative somatosensory potential monitoring
    • Mostegl A, Bauer R, Eichenauer M. Intraoperative somatosensory potential monitoring. Spine 1988;13:396-400.
    • (1988) Spine , vol.13 , pp. 396-400
    • Mostegl, A.1    Bauer, R.2    Eichenauer, M.3
  • 16
    • 0025991549 scopus 로고
    • Dissociation of neurogenic motor and somatosensory evoked potentials
    • Mustain WD, Kendig RJ. Dissociation of neurogenic motor and somatosensory evoked potentials. Spine 1991;16:851-1853.
    • (1991) Spine , vol.16 , pp. 851-1853
    • Mustain, W.D.1    Kendig, R.J.2
  • 17
    • 0020769848 scopus 로고
    • Intraoperative somatosensory-evoked potentials
    • Raudzens PA. Intraoperative somatosensory-evoked potentials. Anesthesiology 1983;58:593.
    • (1983) Anesthesiology , vol.58 , pp. 593
    • Raudzens, P.A.1
  • 18
    • 0023127011 scopus 로고
    • Monitoring of cortical evoked potentials during surgical procedures on the cervical spine
    • Veilleux M, Daube JR, Cucchiara RF. Monitoring of cortical evoked potentials during surgical procedures on the cervical spine. Mayo Clin Proc 1987;62:256-264.
    • (1987) Mayo Clin Proc , vol.62 , pp. 256-264
    • Veilleux, M.1    Daube, J.R.2    Cucchiara, R.F.3
  • 19
    • 0025968403 scopus 로고
    • Motor evoked potential monitoring during neurosurgical operations on the spinal cord
    • Zentner J. Motor evoked potential monitoring during neurosurgical operations on the spinal cord. Neurosurg Rev 1991; 14:29-36.
    • (1991) Neurosurg Rev , vol.14 , pp. 29-36
    • Zentner, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.