메뉴 건너뛰기




Volumn 10, Issue 1, 1999, Pages 102-106

Application and validation of three-dimensional data sets from a phase contrast mr angiography for preoperative computer simulation of brain tumors

Author keywords

3D images; Brain tumor; Motor cortex; Phase contrast MRA; Surgical planning

Indexed keywords

ADULT; AGED; ARTICLE; ASTROCYTOMA; BRAIN SURGERY; BRAIN TUMOR; CLINICAL ARTICLE; COMPUTER SIMULATION; CONTROLLED STUDY; FEMALE; GLIOBLASTOMA; HUMAN; IMAGE ANALYSIS; MAGNETIC RESONANCE ANGIOGRAPHY; MALE; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; THREE DIMENSIONAL IMAGING; TREATMENT PLANNING; VALIDATION PROCESS;

EID: 0032795423     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2586(199907)10:1<102::AID-JMRI15>3.0.CO;2-C     Document Type: Article
Times cited : (4)

References (11)
  • 1
    • 0030455308 scopus 로고    scopus 로고
    • Functional magnetic resonance imaging in a stereotactic set up
    • Debus J, Essig M, Schad LR, et al. Functional magnetic resonance imaging in a stereotactic set up. Magn Reson Imaging 1996;14:1007-1012.
    • (1996) Magn Reson Imaging , vol.14 , pp. 1007-1012
    • Debus, J.1    Essig, M.2    Schad, L.R.3
  • 2
    • 0028811029 scopus 로고
    • Functional mapping of the sensorimotor cortex: Combined use of magnetoencephalography, functional MRI, and motor evoked potentials
    • Morioka T, Mizushima A, Yamamoto T, et al. Functional mapping of the sensorimotor cortex: combined use of magnetoencephalography, functional MRI, and motor evoked potentials. Neuroradiology 1995;37:526-530.
    • (1995) Neuroradiology , vol.37 , pp. 526-530
    • Morioka, T.1    Mizushima, A.2    Yamamoto, T.3
  • 3
    • 9544252155 scopus 로고    scopus 로고
    • Functional MRI: Primary motor cortex localization in patients with brain tumors
    • Righini A, de Divitiis O, Prinster A, et al. Functional MRI: primary motor cortex localization in patients with brain tumors. J Comput Assist Tomogr 1996;20:702-708.
    • (1996) J Comput Assist Tomogr , vol.20 , pp. 702-708
    • Righini, A.1    De Divitiis, O.2    Prinster, A.3
  • 4
    • 0030837423 scopus 로고    scopus 로고
    • Usefulness of two-dimensional time-of-flight MR angiography combined with surface anatomy scanning for convexity lesions
    • Pant B, Sumida M, Kurisu K, et al. Usefulness of two-dimensional time-of-flight MR angiography combined with surface anatomy scanning for convexity lesions. Neurosurg Rev 1997;20:108-113.
    • (1997) Neurosurg Rev , vol.20 , pp. 108-113
    • Pant, B.1    Sumida, M.2    Kurisu, K.3
  • 5
    • 19244363924 scopus 로고    scopus 로고
    • Functional mapping of human sensorimotor cortex with 3D BOLD fMRI correlates highly with H2 (15) O PET rCBF
    • Ramsey NF, Kirkby BS, Van Gelderen P, et al. Functional mapping of human sensorimotor cortex with 3D BOLD fMRI correlates highly with H2 (15) O PET rCBF. J Cereb Blood Flow Metab 1996;16:755-764.
    • (1996) J Cereb Blood Flow Metab , vol.16 , pp. 755-764
    • Ramsey, N.F.1    Kirkby, B.S.2    Van Gelderen, P.3
  • 6
    • 0029035318 scopus 로고
    • Functional magnetic resonance imaging at 1T: Motor cortex, supplementary motor area and visual cortex activation
    • Santosh CG, Rimmington JE, Best JJ. Functional magnetic resonance imaging at 1T: Motor cortex, supplementary motor area and visual cortex activation. Br J Radiol 1995;68:369-374.
    • (1995) Br J Radiol , vol.68 , pp. 369-374
    • Santosh, C.G.1    Rimmington, J.E.2    Best, J.J.3
  • 7
    • 0028325533 scopus 로고
    • Localization of motor areas adjacent to arteriovenous malformations. A positron emission tomographic study
    • Grafton ST, Martin NA, Mazziotta JC, Woods RP, Vinuela F, Phelps ME. Localization of motor areas adjacent to arteriovenous malformations. A positron emission tomographic study. J Neuroimaging 1994;4:97-103.
    • (1994) J Neuroimaging , vol.4 , pp. 97-103
    • Grafton, S.T.1    Martin, N.A.2    Mazziotta, J.C.3    Woods, R.P.4    Vinuela, F.5    Phelps, M.E.6
  • 8
    • 0027954993 scopus 로고
    • Functional 2D and 3D magnetic resonance imaging of motor cortex stimulation at high spatial resolution using standard 1.5T imager
    • Schad LR, Wenz F, Knopp MV, Baudendistel K, Muller E, Lorenz WJ. Functional 2D and 3D magnetic resonance imaging of motor cortex stimulation at high spatial resolution using standard 1.5T imager. Magn Reson Imaging 1994;12:9-15.
    • (1994) Magn Reson Imaging , vol.12 , pp. 9-15
    • Schad, L.R.1    Wenz, F.2    Knopp, M.V.3    Baudendistel, K.4    Muller, E.5    Lorenz, W.J.6
  • 9
    • 0028398378 scopus 로고
    • Inflow versus deoxyhemoglobin effects in BOLD functional MRI using gradient echoes at 1.5T
    • Duyn JH, Moonen CT, van Yperen GH, de Boer RW, Luyten PR. Inflow versus deoxyhemoglobin effects in BOLD functional MRI using gradient echoes at 1.5T. NMR Biomed 1994;7:83-88.
    • (1994) NMR Biomed , vol.7 , pp. 83-88
    • Duyn, J.H.1    Moonen, C.T.2    Van Yperen, G.H.3    De Boer, R.W.4    Luyten, P.R.5
  • 10
    • 0027265576 scopus 로고
    • Identification of vascular structures as a major source of signal contrast in high resolution 2D and 3D functional activation imaging of the motor cortex at 1.5T: Preliminary results
    • Lai S, Hopkins AL, Haacke EM, et al. Identification of vascular structures as a major source of signal contrast in high resolution 2D and 3D functional activation imaging of the motor cortex at 1.5T: preliminary results. Magn Reson Med 1993;30:387-392.
    • (1993) Magn Reson Med , vol.30 , pp. 387-392
    • Lai, S.1    Hopkins, A.L.2    Haacke, E.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.