메뉴 건너뛰기




Volumn 5, Issue 3, 1999, Pages 179-181

Measuring depth depends on frequency in electrical skin impedance measurements

Author keywords

Finite element method; Frequency; Measuring depth; Skin impedance

Indexed keywords

ARTICLE; ELECTRODE; FINITE ELEMENT ANALYSIS; HUMAN; HYDRATION; MEASUREMENT; SKIN CONDUCTANCE; STRATUM CORNEUM;

EID: 0032793114     PISSN: 0909752X     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1600-0846.1999.tb00128.x     Document Type: Article
Times cited : (88)

References (13)
  • 1
    • 0032079158 scopus 로고    scopus 로고
    • Methods for information extraction from impedance spectra of biological tissue, in particular skin and oral mucosa - A critical review and suggestions for the future
    • Ollmar S. Methods for information extraction from impedance spectra of biological tissue, in particular skin and oral mucosa - a critical review and suggestions for the future. Bioelectrochem Bioenerget 1998: 45: 157-160.
    • (1998) Bioelectrochem Bioenerget , vol.45 , pp. 157-160
    • Ollmar, S.1
  • 2
    • 0030956066 scopus 로고    scopus 로고
    • Allergic contact reactions in the skin assessed by electrical impedance - A pilot study
    • Nicander I, Ollmar S, Lundh Rozell B, Emtestam L. Allergic contact reactions in the skin assessed by electrical impedance - a pilot study. Skin Res Technol 1997: 3: 121-125.
    • (1997) Skin Res Technol , vol.3 , pp. 121-125
    • Nicander, I.1    Ollmar, S.2    Lundh Rozell, B.3    Emtestam, L.4
  • 4
  • 7
    • 0001347553 scopus 로고
    • An instrument for the evaluation of skin hydration by electrical admittance measurements
    • Martinsen ØG, Grimnes S, Karlsen J. An instrument for the evaluation of skin hydration by electrical admittance measurements. Innov Tech Biol Med 1993: 14: 588-596.
    • (1993) Innov Tech Biol Med , vol.14 , pp. 588-596
    • Martinsen, Ø.G.1    Grimnes, S.2    Karlsen, J.3
  • 9
    • 0005248155 scopus 로고    scopus 로고
    • Measurement of the effect of topical liposome preparations by low frequency electrical susceptance
    • Martinsen ØG, Grimnes S, Henriksen I, Karlsen J. Measurement of the effect of topical liposome preparations by low frequency electrical susceptance. Innov Tech Biol Med 1996: 17: 217-222.
    • (1996) Innov Tech Biol Med , vol.17 , pp. 217-222
    • Martinsen, Ø.G.1    Grimnes, S.2    Henriksen, I.3    Karlsen, J.4
  • 10
    • 0031008153 scopus 로고    scopus 로고
    • EEMCO guidance for the assessment of stratum corneum hydration: Electrical methods
    • Berardesca E. EEMCO guidance for the assessment of stratum corneum hydration: electrical methods. Skin Res Technol 1997: 3: 126-132.
    • (1997) Skin Res Technol , vol.3 , pp. 126-132
    • Berardesca, E.1
  • 11
    • 0022619969 scopus 로고
    • Characteristics of skin admittance for dry electrodes and the measurement of skin moisturisation
    • Yamamoto Y, Yamamoto T, Ozawa T. Characteristics of skin admittance for dry electrodes and the measurement of skin moisturisation. Med Biol Eng Comput 1986: 24: 71-77.
    • (1986) Med Biol Eng Comput , vol.24 , pp. 71-77
    • Yamamoto, Y.1    Yamamoto, T.2    Ozawa, T.3
  • 12
    • 0016938239 scopus 로고
    • Electrical properties of the epidermal stratum corneum
    • Yamamoto T, Yamamoto Y. Electrical properties of the epidermal stratum corneum. Med Biol Eng 1976: 14: 151-158.
    • (1976) Med Biol Eng , vol.14 , pp. 151-158
    • Yamamoto, T.1    Yamamoto, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.