메뉴 건너뛰기




Volumn 13, Issue 3, 1999, Pages 139-141

Performance of a new, fast D-dimer test (IL Test™ D-Dimer) for the management of outpatients with suspected deep vein thrombosis in emergency situations

Author keywords

[No Author keywords available]

Indexed keywords

D DIMER;

EID: 0032792270     PISSN: 02689499     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0268-9499(99)90101-7     Document Type: Article
Times cited : (18)

References (12)
  • 2
    • 0030986321 scopus 로고    scopus 로고
    • The use of d-dimer testing and impedance plethysmographic examination in patients with clinical indications of deep vein thrombosis
    • Ginsberg JS, Kearon C, Douketis J et al. The use of d-dimer testing and impedance plethysmographic examination in patients with clinical indications of deep vein thrombosis. Arch Intern Med 1997; 157: 1077-1081.
    • (1997) Arch Intern Med , vol.157 , pp. 1077-1081
    • Ginsberg, J.S.1    Kearon, C.2    Douketis, J.3
  • 3
    • 7344253585 scopus 로고    scopus 로고
    • Simplified compression ultrasound strategy for the diagnostic management of patients with clinically suspected venous thrombosis
    • Bernardi E, Prandoni P, Lensing AWA et al. Simplified compression ultrasound strategy for the diagnostic management of patients with clinically suspected venous thrombosis. Brit Med J 1998; 317: 1037-1040.
    • (1998) Brit Med J , vol.317 , pp. 1037-1040
    • Bernardi, E.1    Prandoni, P.2    Lensing, A.W.A.3
  • 4
    • 0028266671 scopus 로고
    • Comparison of three D-dimer assays for the diagnosis of DVT: ELISA, latex and an immunofiltration assay (Nycocard D-Dimer)
    • Dale S, Gogstad GO, Brosstad F et al. Comparison of three D-dimer assays for the diagnosis of DVT: ELISA, latex and an immunofiltration assay (Nycocard D-Dimer). Thromb Haemost 1994; 71: 270-274.
    • (1994) Thromb Haemost , vol.71 , pp. 270-274
    • Dale, S.1    Gogstad, G.O.2    Brosstad, F.3
  • 5
    • 0029040535 scopus 로고
    • Application of a bedside whole blood D-dimer assay in the diagnosis of deep vein thrombosis
    • Brenner B, Pery M, Lanir N et al. Application of a bedside whole blood D-dimer assay in the diagnosis of deep vein thrombosis. Blood Coagul Fibrinol 1995; 6: 219-222.
    • (1995) Blood Coagul Fibrinol , vol.6 , pp. 219-222
    • Brenner, B.1    Pery, M.2    Lanir, N.3
  • 6
    • 0028925172 scopus 로고
    • A novel and rapid whole-blood assay for D-dimer in patients with clinically suspected beep vein thrombosis
    • Wells PS, Brill-Edwards P, Stevens P et al. A novel and rapid whole-blood assay for D-dimer in patients with clinically suspected beep vein thrombosis. Circulation 1995; 91: 2184-2187
    • (1995) Circulation , vol.91 , pp. 2184-2187
    • Wells, P.S.1    Brill-Edwards, P.2    Stevens, P.3
  • 7
    • 0029987081 scopus 로고    scopus 로고
    • Evaluation of a new rapid quantitative d-dimer assay in patients with clinically suspected deep vein thrombosis
    • D'Angelo A, D'Alessandro G, Tomassini L, Pittet JL, Dupuy G, Crippa L. Evaluation of a new rapid quantitative d-dimer assay in patients with clinically suspected deep vein thrombosis. Thromb Haemost 1996; 75: 412-416.
    • (1996) Thromb Haemost , vol.75 , pp. 412-416
    • D'Angelo, A.1    D'Alessandro, G.2    Tomassini, L.3    Pittet, J.L.4    Dupuy, G.5    Crippa, L.6
  • 8
    • 0029843361 scopus 로고    scopus 로고
    • D-dimer test and diagnosis of deep vein thrombosis: A comparative study of 7 assays
    • Elias A, Aptel I, Hue B et al. D-dimer test and diagnosis of deep vein thrombosis: a comparative study of 7 assays. Thromb Haemost 1996; 76: 518-522.
    • (1996) Thromb Haemost , vol.76 , pp. 518-522
    • Elias, A.1    Aptel, I.2    Hue, B.3
  • 9
    • 0030614846 scopus 로고    scopus 로고
    • Reliability of five rapid d-dimer assays compared to ELISA in the exclusion of deep venous thrombosis
    • Janssen MCH, Heebels AE, Demetz M et al. Reliability of five rapid d-dimer assays compared to ELISA in the exclusion of deep venous thrombosis. Thromb Haemost 1997; 77: 262-266.
    • (1997) Thromb Haemost , vol.77 , pp. 262-266
    • Janssen, M.C.H.1    Heebels, A.E.2    Demetz, M.3
  • 10
    • 0031044454 scopus 로고    scopus 로고
    • Comparison of immunofiltration assay of plasma d-dimer with diagnostic imaging in deep vein thrombosis
    • Killick SB, Pentek PG, Mercieca JE, Clarke MF, Bevan DH. Comparison of immunofiltration assay of plasma d-dimer with diagnostic imaging in deep vein thrombosis. Br J Haematol 1997; 96: 846-849.
    • (1997) Br J Haematol , vol.96 , pp. 846-849
    • Killick, S.B.1    Pentek, P.G.2    Mercieca, J.E.3    Clarke, M.F.4    Bevan, D.H.5
  • 11
    • 0030849322 scopus 로고    scopus 로고
    • Comparison of new rapid methods for d-dimer measurement to exclude deep vein thrombosis in symptomatic outpatients
    • Legnani C, Pancani C, Palareti G et al. Comparison of new rapid methods for d-dimer measurement to exclude deep vein thrombosis in symptomatic outpatients. Blood Coagul Fibrinol 1997; 8: 296-302.
    • (1997) Blood Coagul Fibrinol , vol.8 , pp. 296-302
    • Legnani, C.1    Pancani, C.2    Palareti, G.3
  • 12
    • 0030973116 scopus 로고    scopus 로고
    • Accuracy of two newly described d-dimer tests in patients with suspected deep venous thrombosis
    • Scarano L, Bemardi E, Prandoni P et al. Accuracy of two newly described d-dimer tests in patients with suspected deep venous thrombosis. Thromb Res 1997; 86: 93-99.
    • (1997) Thromb Res , vol.86 , pp. 93-99
    • Scarano, L.1    Bemardi, E.2    Prandoni, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.