메뉴 건너뛰기




Volumn 10, Issue 2, 1999, Pages 216-219

Electron spin resonance (ESR) probe for interventional MRI instrument localization

Author keywords

ESR; Interventional MRI; MRI guided procedures

Indexed keywords

ARTICLE; ARTIFACT; BIOPSY; DEVICE; ELECTRON SPIN RESONANCE; ELECTRONICS; INTERVENTIONAL RADIOLOGY; NEEDLE; NUCLEAR MAGNETIC RESONANCE IMAGING; PHANTOM; PRIORITY JOURNAL; SURGICAL INSTRUMENT;

EID: 0032790578     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2586(199908)10:2<216::AID-JMRI17>3.0.CO;2-N     Document Type: Article
Times cited : (6)

References (9)
  • 1
    • 0029422063 scopus 로고
    • Comparison of relative accuracy between a mechanical and an optical position tracker for image-guided neurosurgery
    • Rohling R, Munger P, Hollerbach JM, Peter T. Comparison of relative accuracy between a mechanical and an optical position tracker for image-guided neurosurgery. J Image Guided Surg 1995;1:30-34.
    • (1995) J Image Guided Surg , vol.1 , pp. 30-34
    • Rohling, R.1    Munger, P.2    Hollerbach, J.M.3    Peter, T.4
  • 2
    • 0029114935 scopus 로고
    • Interactive MR-guided biopsy in an open-configuration MR imaging system
    • Silverman SG, Collick BD, Figueira MR, et al. Interactive MR-guided biopsy in an open-configuration MR imaging system. Radiology 1995;197:175-181.
    • (1995) Radiology , vol.197 , pp. 175-181
    • Silverman, S.G.1    Collick, B.D.2    Figueira, M.R.3
  • 3
    • 0028474226 scopus 로고
    • Micro-stereometry: A frameless computerized navigating system for open microsurgery
    • Horstmann GA, Reinhardt HF. Micro-stereometry: a frameless computerized navigating system for open microsurgery. Comput Med Imaging Graphics 1994;18:229-233.
    • (1994) Comput Med Imaging Graphics , vol.18 , pp. 229-233
    • Horstmann, G.A.1    Reinhardt, H.F.2
  • 4
    • 22644437498 scopus 로고    scopus 로고
    • Magnetic resonance imaging guided breast biopsy using a frameless stereotactic technique
    • deSouza NM, Coutts GA, Puni RK, Young IR. Magnetic resonance imaging guided breast biopsy using a frameless stereotactic technique. Clin Radiol 1996;51:425-428.
    • (1996) Clin Radiol , vol.51 , pp. 425-428
    • DeSouza, N.M.1    Coutts, G.A.2    Puni, R.K.3    Young, I.R.4
  • 5
    • 0029896023 scopus 로고    scopus 로고
    • Needle localization in MR-guided biopsy and aspiration: Effects of field strength, sequence design, and magnetic field orientation
    • Lewin JS, Duerk JL, Jain VR, et al. Needle localization in MR-guided biopsy and aspiration: effects of field strength, sequence design, and magnetic field orientation. AJR 1996;166:1337-1345.
    • (1996) AJR , vol.166 , pp. 1337-1345
    • Lewin, J.S.1    Duerk, J.L.2    Jain, V.R.3
  • 6
    • 0029907019 scopus 로고    scopus 로고
    • Visualization of dedicated catheters using fast scanning techniques with potential for MR-guided vascular interventions
    • Bakker CJ, Hoogeveen RM, Weber J, et al. Visualization of dedicated catheters using fast scanning techniques with potential for MR-guided vascular interventions. Magn Reson Med 1996;36:816-820.
    • (1996) Magn Reson Med , vol.36 , pp. 816-820
    • Bakker, C.J.1    Hoogeveen, R.M.2    Weber, J.3
  • 7
    • 0030797354 scopus 로고    scopus 로고
    • Active biplanar MR tracking for biopsies in humans
    • Steiner P, Erhart P, Heske N, et al. Active biplanar MR tracking for biopsies in humans. AJR 1997;169:735-738.
    • (1997) AJR , vol.169 , pp. 735-738
    • Steiner, P.1    Erhart, P.2    Heske, N.3
  • 8
    • 0345362519 scopus 로고    scopus 로고
    • Pat. U.S. 5,488,950. Stabilizer for MRI system. Picker Nordstar, Inc. Finland (Ehnholm, G.). Appl. 212,426 March 14, 1994
    • Pat. U.S. 5,488,950. Stabilizer for MRI system. Picker Nordstar, Inc. Finland (Ehnholm, G.). Appl. 212,426 March 14, 1994.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.