메뉴 건너뛰기




Volumn 44, Issue 8, 1999, Pages 1905-1919

An improved technique for comparing Gamma Knife dose-volume distributions in stereotactic radiosurgery

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHM; ARTICLE; DEVICE; HISTOGRAM; PRIORITY JOURNAL; RADIATION DOSE DISTRIBUTION; RADIOSURGERY; STEREOTAXIC SURGERY; TECHNIQUE;

EID: 0032790321     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/44/8/305     Document Type: Article
Times cited : (2)

References (21)
  • 2
    • 0022969959 scopus 로고
    • A 'natural' volume-dose histogram for brachytherapy
    • Anderson L L 1986 A 'natural' volume-dose histogram for brachytherapy Med. Phys. 13 898-903
    • (1986) Med. Phys. , vol.13 , pp. 898-903
    • Anderson, L.L.1
  • 5
    • 0003651542 scopus 로고
    • Prescribing, recording, and reporting photon beam therapy
    • Bethesda, MD: ICRU
    • International Commission on Radiation Units and Measurements (ICRU) 1993 Prescribing, recording, and reporting photon beam therapy ICRU Report 50 (Bethesda, MD: ICRU)
    • (1993) ICRU Report , vol.50
  • 7
    • 0028909044 scopus 로고
    • The application of dose-volume histograms to the Paris and Manchester systems of brachytherapy dosimetry
    • Langmack K A and Thomas S J 1995 The application of dose-volume histograms to the Paris and Manchester systems of brachytherapy dosimetry Br. J. Radiat. 68 42-8
    • (1995) Br. J. Radiat. , vol.68 , pp. 42-48
    • Langmack, K.A.1    Thomas, S.J.2
  • 9
    • 0026517467 scopus 로고
    • The potential of ytterbium 169 in brachytherapy: A brief physical and radiobiological assessment
    • Loft S M, Coles I P and Dale R G 1992 The potential of ytterbium 169 in brachytherapy: a brief physical and radiobiological assessment Br. J. Radiat. 65 252-7
    • (1992) Br. J. Radiat. , vol.65 , pp. 252-257
    • Loft, S.M.1    Coles, I.P.2    Dale, R.G.3
  • 10
    • 0025001833 scopus 로고
    • The incorporation of specific tissue/nuclide attenuation data into the Anderson method for producing brachytherapy volume-dose histograms
    • Loft S M and Dale R G 1990 The incorporation of specific tissue/nuclide attenuation data into the Anderson method for producing brachytherapy volume-dose histograms Phys. Med. Biol. 35 1519-31
    • (1990) Phys. Med. Biol. , vol.35 , pp. 1519-1531
    • Loft, S.M.1    Dale, R.G.2
  • 13
    • 0025029372 scopus 로고
    • Random sampling for evaluating treatment plans
    • Niemierko A and Goitein M 1990 Random sampling for evaluating treatment plans Med. Phys. 17 753-62
    • (1990) Med. Phys. , vol.17 , pp. 753-762
    • Niemierko, A.1    Goitein, M.2
  • 16
    • 0342617576 scopus 로고    scopus 로고
    • A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: Application to the prostate
    • van'T Riet A M S, Mak A C A, Moerland M A, Elders L H and Van der Zee W 1997 A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: application to the prostate Int. J. Radiat. Oncol. Biol. Phys. 37 731-6
    • (1997) Int. J. Radiat. Oncol. Biol. Phys. , vol.37 , pp. 731-736
    • Van't Riet, A.M.S.1    Mak, A.C.A.2    Moerland, M.A.3    Elders, L.H.4    Van Der Zee, W.5
  • 17
    • 0023162638 scopus 로고
    • The Sheffield stereotactic radiosurgery unit: Physical characteristics and principles of operation
    • Walton L, Bomford C K and Ramsden D 1987 The Sheffield stereotactic radiosurgery unit: physical characteristics and principles of operation Br. J. Radiat. 60 897-906
    • (1987) Br. J. Radiat. , vol.60 , pp. 897-906
    • Walton, L.1    Bomford, C.K.2    Ramsden, D.3
  • 18
    • 0030030322 scopus 로고    scopus 로고
    • A phantom study to assess the accuracy of stereotactic localization, using T1-weighted magnetic resonance imaging with the Leksell stereotactic system
    • Walton L, Hampshire A, Forster DMC and Kemeny A A 1996 A phantom study to assess the accuracy of stereotactic localization, using T1-weighted magnetic resonance imaging with the Leksell stereotactic system Neurosurgery 35 170-8
    • (1996) Neurosurgery , vol.35 , pp. 170-178
    • Walton, L.1    Hampshire, A.2    Forster, D.M.C.3    Kemeny, A.A.4
  • 19
    • 0030923738 scopus 로고    scopus 로고
    • Stereotactic localisation with magnetic resonance imaging: A phantom study to compare the accuracy obtained using two-dimensional and three-dimensional data acquisitions
    • _ 1997 Stereotactic localisation with magnetic resonance imaging: a phantom study to compare the accuracy obtained using two-dimensional and three-dimensional data acquisitions Neurosurgery 41 131-9
    • (1997) Neurosurgery , vol.41 , pp. 131-139
  • 20
    • 0023883007 scopus 로고
    • A dose homogeneity index for evaluating Ir-192 interstitial breast implants
    • Wu A, Ulin K and Sternick E S 1988 A dose homogeneity index for evaluating Ir-192 Interstitial breast implants Med. Phys. 15 104-7
    • (1988) Med. Phys. , vol.15 , pp. 104-107
    • Wu, A.1    Ulin, K.2    Sternick, E.S.3
  • 21
    • 0031045107 scopus 로고    scopus 로고
    • Functional dose-volume histograms for functionally heterogeneous normal organs
    • Yong L, Spelbring D R and Chen G T Y 1997 Functional dose-volume histograms for functionally heterogeneous normal organs Phys. Med. Biol. 42 345-56
    • (1997) Phys. Med. Biol. , vol.42 , pp. 345-356
    • Yong, L.1    Spelbring, D.R.2    Chen, G.T.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.