메뉴 건너뛰기




Volumn 38, Issue 4, 1999, Pages 153-160

Comparative study of five commercial reagents for preparing normal and leukaemic lymphocytes for immunophenotypic analysis by flow cytometry

Author keywords

Chronic lymphocytic leukaemia; Flow cytometry; Leucocyte preparation

Indexed keywords

BOVINE SERUM ALBUMIN; BUFFER; DIETHYLENE GLYCOL; DYE; FIXATIVE; FORMIC ACID; LDS 751; LYMPHOCYTE ANTIGEN; MEMBRANE AFFECTING AGENT; NUCLEIC ACID; PARAFORMALDEHYDE; PHOSPHATE; REAGENT; SODIUM CARBONATE; SODIUM SULFATE; STABILIZING AGENT; TROMETAMOL; UNCLASSIFIED DRUG;

EID: 0032787815     PISSN: 01964763     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-0320(19990815)38:4<153::AID-CYTO2>3.0.CO;2-E     Document Type: Article
Times cited : (31)

References (17)
  • 1
    • 0344646323 scopus 로고
    • Chronic lymphoid leukaemias
    • Bain BJ, editor. London: Gower Medical Publishing
    • Bain BJ. Chronic lymphoid leukaemias. In: Bain BJ, editor. Leukaemia diagnosis: a guide to the FAB classification. London: Gower Medical Publishing; 1990. p 89-105.
    • (1990) Leukaemia Diagnosis: A Guide to the FAB Classification , pp. 89-105
    • Bain, B.J.1
  • 2
    • 0030798115 scopus 로고    scopus 로고
    • Comparative analysis of whole blood lysis methods for flow cytometry
    • Bossuyt X, Marti GE, Fleisher TA. Comparative analysis of whole blood lysis methods for flow cytometry. Cytometry 1997;30:124-133.
    • (1997) Cytometry , vol.30 , pp. 124-133
    • Bossuyt, X.1    Marti, G.E.2    Fleisher, T.A.3
  • 4
    • 0032190570 scopus 로고    scopus 로고
    • Determination of CD4 antigen density on cells: Role of antibody valency, avidity, clones and conjugation
    • Davis KA, Abrams B, Iyer SB, Hoffman RA, Bishop JE. Determination of CD4 antigen density on cells: role of antibody valency, avidity, clones and conjugation. Cytometry 1998;33:197-205.
    • (1998) Cytometry , vol.33 , pp. 197-205
    • Davis, K.A.1    Abrams, B.2    Iyer, S.B.3    Hoffman, R.A.4    Bishop, J.E.5
  • 5
    • 0028631045 scopus 로고
    • Immunophenotyping in the diagnosis of chronic lymphoproliferative disorders
    • General Haematology Task Force of BCSH. Immunophenotyping in the diagnosis of chronic lymphoproliferative disorders. J Clin Path 1994;47:871-887.
    • (1994) J Clin Path , vol.47 , pp. 871-887
  • 6
    • 0028917997 scopus 로고
    • Altered expression of CD11b/CD18 on human monocytes after cell preparation procedures
    • Lundahl J, Hallden G, Hallgren M, Skold CM, Hed J. Altered expression of CD11b/CD18 on human monocytes after cell preparation procedures. J Immunol Meth 1995;180:93-100.
    • (1995) J Immunol Meth , vol.180 , pp. 93-100
    • Lundahl, J.1    Hallden, G.2    Hallgren, M.3    Skold, C.M.4    Hed, J.5
  • 8
    • 0027365468 scopus 로고
    • Quantitation of adhesion molecules and other function-associated antigens on human peripheral blood leucocytes
    • Macey MG, McCarthy DA. Quantitation of adhesion molecules and other function-associated antigens on human peripheral blood leucocytes. Cytometry 1993;14:898-908.
    • (1993) Cytometry , vol.14 , pp. 898-908
    • Macey, M.G.1    McCarthy, D.A.2
  • 9
    • 0028928480 scopus 로고
    • Effects of cell purification methods on CD11b and L-selectin expression as well as the adherence and activation of leucocytes
    • Macey MG, McCarthy DA, Vordermeier S, Newland AC, Brown KA. Effects of cell purification methods on CD11b and L-selectin expression as well as the adherence and activation of leucocytes. J Immunol Meth 1005;181:211-219.
    • (1005) J Immunol Meth , vol.181 , pp. 211-219
    • Macey, M.G.1    McCarthy, D.A.2    Vordermeier, S.3    Newland, A.C.4    Brown, K.A.5
  • 10
    • 0031586968 scopus 로고    scopus 로고
    • How should CD34+ cells be analysed? A study of three classes of antibody and five leucocyte preparation procedures
    • Macey MG, McCarthy DA, van Agthovan A, Newland AC. How should CD34+ cells be analysed? A study of three classes of antibody and five leucocyte preparation procedures. J Immunol Meth 1997;204:175-188.
    • (1997) J Immunol Meth , vol.204 , pp. 175-188
    • Macey, M.G.1    McCarthy, D.A.2    Van Agthovan, A.3    Newland, A.C.4
  • 11
    • 0031003208 scopus 로고    scopus 로고
    • The Q-Prep system: Effects on the apparent expression of leucocyte surface antigens
    • Macey MG, McCarthy DA, Davies C, Newland AC. The Q-Prep system: effects on the apparent expression of leucocyte surface antigens. Cytometry 1997;30:67-71.
    • (1997) Cytometry , vol.30 , pp. 67-71
    • Macey, M.G.1    McCarthy, D.A.2    Davies, C.3    Newland, A.C.4
  • 12
    • 0026337686 scopus 로고
    • The classification of lymphoid leukaemias
    • Matutes E, Catovsky D. The classification of lymphoid leukaemias. Leuk Lymph 1991;5:153-155.
    • (1991) Leuk Lymph , vol.5 , pp. 153-155
    • Matutes, E.1    Catovsky, D.2
  • 14
    • 0027203387 scopus 로고
    • A simple flow cytometric procedure for the determination of surface antigens on unfixed leucocytes in whole blood
    • McCarthy DA, Macey MG. A simple flow cytometric procedure for the determination of surface antigens on unfixed leucocytes in whole blood. J Immunol Meth 1993;163:155-160.
    • (1993) J Immunol Meth , vol.163 , pp. 155-160
    • McCarthy, D.A.1    Macey, M.G.2
  • 15
    • 0028144891 scopus 로고
    • Effect of fixation on quantification of the expression of leucocyte function associated surface antigens
    • McCarthy DA, Macey MG, Cahill MR, Newland AC. Effect of fixation on quantification of the expression of leucocyte function associated surface antigens. Cytometry 1994;17:39-49.
    • (1994) Cytometry , vol.17 , pp. 39-49
    • McCarthy, D.A.1    Macey, M.G.2    Cahill, M.R.3    Newland, A.C.4
  • 16
    • 0032190263 scopus 로고    scopus 로고
    • Quantitative fluorescence flow cytometry: A comparison of three techniques for direct and indirect immunofluorescence
    • Serke S, Lessen van A, Huhn D. Quantitative fluorescence flow cytometry: a comparison of three techniques for direct and indirect immunofluorescence. Cytometry 1998;33:179-187.
    • (1998) Cytometry , vol.33 , pp. 179-187
    • Serke, S.1    Van Lessen, A.2    Huhn, D.3
  • 17
    • 0029056169 scopus 로고
    • Evaluation of red blood cell lysing solutions for the detection of intracellular antigens by flow cytometry
    • Tiirikainen MI. Evaluation of red blood cell lysing solutions for the detection of intracellular antigens by flow cytometry. Cytometry 1995;20:341-348.
    • (1995) Cytometry , vol.20 , pp. 341-348
    • Tiirikainen, M.I.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.