메뉴 건너뛰기




Volumn 47, Issue 11, 1999, Pages 970-975

The usefulness of intraoperatively registered, electrically evoked stapediusreflex for the programming of cochlear implants in children;Bedeutung der intraoperativ registrierten elektrischen stapediusreflexschwelle fur die cochlear-implant-anpassung bei kindern

Author keywords

Cochlear implant; Paediatric audiology; Speech processor; Stapedius reflex

Indexed keywords

ACOUSTIC REFLEX; ACOUSTICS; ARTICLE; AUDITORY THRESHOLD; CHILD; CLINICAL ARTICLE; COCHLEA PROSTHESIS; ELECTRODE; ELECTROSTIMULATION; HUMAN; INTRAOPERATIVE PERIOD; LOUDNESS; SPEECH;

EID: 0032787090     PISSN: 00176192     EISSN: None     Source Type: Journal    
DOI: 10.1007/s001060050477     Document Type: Article
Times cited : (8)

References (11)
  • 1
    • 0028946925 scopus 로고
    • Use of test-retest measures to evaluate performance stability in adults with cochlear implants
    • Skinner MW, Holden LK, Demorest ME, Holden TA (1995) Use of test-retest measures to evaluate performance stability in adults with cochlear implants. Ear Hear 16: 187-197
    • (1995) Ear Hear , vol.16 , pp. 187-197
    • Skinner, M.W.1    Holden, L.K.2    Demorest, M.E.3    Holden, T.A.4
  • 2
    • 0344459143 scopus 로고
    • Programming the Nucleus 22 channel cochlear implant for young children: Issues and problems
    • Hochmair-Desoyer IJ, Hochmair ES (eds) Manz, Wien
    • Sheppard S, Cope Y, Twomey T (1994) Programming the Nucleus 22 channel cochlear implant for young children: issues and problems. In: Hochmair-Desoyer IJ, Hochmair ES (eds) Advances in cochlear implants. Manz, Wien, pp 270-273
    • (1994) Advances in Cochlear Implants , pp. 270-273
    • Sheppard, S.1    Cope, Y.2    Twomey, T.3
  • 3
    • 0029175714 scopus 로고
    • Algorithmic representation of common ground programming in children with the Nucleus device
    • Battmer RD, Gnadeberg D, Allum-Mecklenburg DJ, Lenarz T (1995) Algorithmic representation of common ground programming in children with the Nucleus device. Adv Otorhinolaryngol 50: 83-90
    • (1995) Adv Otorhinolaryngol , vol.50 , pp. 83-90
    • Battmer, R.D.1    Gnadeberg, D.2    Allum-Mecklenburg, D.J.3    Lenarz, T.4
  • 5
    • 0344028009 scopus 로고    scopus 로고
    • Relationship of intra-operative stapedial reflex thresholds and programming thresholds and comfort levels
    • Yorkshire Cochlear Implant Unit
    • Raine C, Ajayi F, Cruickshank H, Kahn S, Beesley P (1997) Relationship of intra-operative stapedial reflex thresholds and programming thresholds and comfort levels. Reprinted article from XVI world congress of otorhinolaryngology head and neck surgery. Yorkshire Cochlear Implant Unit, pp 237-241
    • (1997) XVI World Congress of Otorhinolaryngology Head and Neck Surgery , pp. 237-241
    • Raine, C.1    Ajayi, F.2    Cruickshank, H.3    Kahn, S.4    Beesley, P.5
  • 6
    • 0028295974 scopus 로고
    • The relationship between electrical acoustic reflex thresholds and behavioral comfort lebels in children and adult cochlear implants patients
    • Spivak LG, Chute PM (1994) The relationship between electrical acoustic reflex thresholds and behavioral comfort lebels in children and adult cochlear implants patients. Ear Hear 15: 184-192
    • (1994) Ear Hear , vol.15 , pp. 184-192
    • Spivak, L.G.1    Chute, P.M.2
  • 7
    • 0025123684 scopus 로고
    • Electrically elicited stapedius reflex in cochlear implant patients
    • Battmer R-D, Laszig R, Lehnhardt E (1990) Electrically elicited stapedius reflex in cochlear implant patients. Ear Hear 11: 370-374
    • (1990) Ear Hear , vol.11 , pp. 370-374
    • Battmer, R.-D.1    Laszig, R.2    Lehnhardt, E.3
  • 8
    • 0028031106 scopus 로고
    • Programming the cochlear implant based on electrical acoustic reflex thresholds: Patients performance
    • Spivak LG, Chute PM, Popp AL, Parisier SC (1994) Programming the cochlear implant based on electrical acoustic reflex thresholds: patients performance. Laryngoscope 104: 1225-1230
    • (1994) Laryngoscope , vol.104 , pp. 1225-1230
    • Spivak, L.G.1    Chute, P.M.2    Popp, A.L.3    Parisier, S.C.4
  • 9
    • 0027008420 scopus 로고
    • Beziehung zwischen dem elektrisch ausgelösten stapediusreflex und der unbehaglichkeitsschwelle bei cochlear-implant-patienten
    • Gattaz G, Battmer RD, Lehnahrdt E, Gnadeberg D (1992) Beziehung zwischen dem elektrisch ausgelösten Stapediusreflex und der Unbehaglichkeitsschwelle bei Cochlear-Implant-Patienten. HNO 40: 480-483
    • (1992) HNO , vol.40 , pp. 480-483
    • Gattaz, G.1    Battmer, R.D.2    Lehnahrdt, E.3    Gnadeberg, D.4
  • 10
    • 0025803921 scopus 로고
    • Acoustic reflex in patients with cochlear implants
    • Stephan K, Welzl-Müller K, Stiglbrunner H (1991) Acoustic reflex in patients with cochlear implants. Am J Otol 12 [Suppl]: 48-51
    • (1991) Am J Otol , vol.12 , Issue.SUPPL. , pp. 48-51
    • Stephan, K.1    Welzl-Müller, K.2    Stiglbrunner, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.