메뉴 건너뛰기




Volumn 87, Issue 1, 1999, Pages 407-414

Effect of I/E ratio on mean alveolar pressure during high-frequency oscillatory ventilation

Author keywords

Gas trapping; High frequency ventilation; Lung volume; Mean airway pressure

Indexed keywords

ANIMAL EXPERIMENT; ARTICLE; CONTROLLED STUDY; DISEASE SIMULATION; ENDOTRACHEAL TUBE; HIGH FREQUENCY OSCILLATION; HIGH FREQUENCY VENTILATION; HYALINE MEMBRANE DISEASE; IN VITRO STUDY; LUNG ALVEOLUS; LUNG VOLUME; NONHUMAN; PRIORITY JOURNAL; RABBIT;

EID: 0032779044     PISSN: 87507587     EISSN: None     Source Type: Journal    
DOI: 10.1152/jappl.1999.87.1.407     Document Type: Article
Times cited : (64)

References (25)
  • 1
    • 0023214523 scopus 로고
    • Heterogeneity of mean alveolar pressure during high-frequency oscillations
    • Allen, J., I. Frantz III, and J. Fredberg. Heterogeneity of mean alveolar pressure during high-frequency oscillations. J. Appl. Physiol. 62: 223-228, 1987.
    • (1987) J. Appl. Physiol. , vol.62 , pp. 223-228
    • Allen, J.1    Frantz I. III2    Fredberg, J.3
  • 3
    • 0022623537 scopus 로고
    • Inadvertent positive end-expiratory pressure during mechanical ventilation
    • Bancalari, E. Inadvertent positive end-expiratory pressure during mechanical ventilation. J. Pediatr. 108: 567-569, 1986.
    • (1986) J. Pediatr. , vol.108 , pp. 567-569
    • Bancalari, E.1
  • 4
    • 0026843127 scopus 로고
    • Correcting for the Bernoulli effect in lateral pressure measurements
    • Bates, J. H., P. D. Sly, J. Sato, B. L. Davey, and B. Suki. Correcting for the Bernoulli effect in lateral pressure measurements. Pediatr. Pulmonol. 12: 251-256, 1992.
    • (1992) Pediatr. Pulmonol. , vol.12 , pp. 251-256
    • Bates, J.H.1    Sly, P.D.2    Sato, J.3    Davey, B.L.4    Suki, B.5
  • 5
    • 0022637641 scopus 로고
    • Long volume during high-frequency oscillation
    • Bryan, A., and A. Slutsky. Long volume during high-frequency oscillation. Am. Rev. Respir. Dis. 133: 928-930, 1986.
    • (1986) Am. Rev. Respir. Dis. , vol.133 , pp. 928-930
    • Bryan, A.1    Slutsky, A.2
  • 6
    • 0024615766 scopus 로고
    • Flow separation, an important mechanism in the formation of mean pulmonary pressure during high-frequency oscillation
    • Bush, E., D. Spahn, P. Niederer, and E. Schmid. Flow separation, an important mechanism in the formation of mean pulmonary pressure during high-frequency oscillation. J. Biomech. Eng. 111: 17-23, 1989.
    • (1989) J. Biomech. Eng. , vol.111 , pp. 17-23
    • Bush, E.1    Spahn, D.2    Niederer, P.3    Schmid, E.4
  • 7
    • 0023792975 scopus 로고
    • Lung hyperinflation in isolated dog lungs during high-frequency oscillation
    • Cha, E., E. Chow, K. Chang, and S. Yamashiro. Lung hyperinflation in isolated dog lungs during high-frequency oscillation. J. Appl Physiol. 65: 1172-1179, 1988.
    • (1988) J. Appl Physiol. , vol.65 , pp. 1172-1179
    • Cha, E.1    Chow, E.2    Chang, K.3    Yamashiro, S.4
  • 8
    • 0002918560 scopus 로고
    • Flow dynamics in the respiratory tract
    • edited by H. Chang and M. Paiva. New York: Dekker
    • Chang, H. Flow dynamics in the respiratory tract. In: Respiratory Physiology - An Analytical Approach, edited by H. Chang and M. Paiva. New York: Dekker, 1989, p. 57-138.
    • (1989) Respiratory Physiology - An Analytical Approach , pp. 57-138
    • Chang, H.1
  • 9
    • 0019415745 scopus 로고
    • Fluid dynamic factors in tracheal pressure measurement
    • Chang, H., and J. Mortola. Fluid dynamic factors in tracheal pressure measurement. J. Appl. Physiol. 51: 218-225, 1981.
    • (1981) J. Appl. Physiol. , vol.51 , pp. 218-225
    • Chang, H.1    Mortola, J.2
  • 10
    • 0021013291 scopus 로고
    • Respiratory system impedance from 4 to 40 Hz in paralyzed intubated infants with respiratory disease
    • Dorkin, H., A. Stark, J. Werthammer, D. Strieder, J. Fredberg, and I. Frantz III. Respiratory system impedance from 4 to 40 Hz in paralyzed intubated infants with respiratory disease. J. Clin. Invest. 72: 903-910, 1983.
    • (1983) J. Clin. Invest. , vol.72 , pp. 903-910
    • Dorkin, H.1    Stark, A.2    Werthammer, J.3    Strieder, D.4    Fredberg, J.5    Frantz I. III6
  • 11
    • 0021916597 scopus 로고
    • Elevated lung volume and alveolar pressure during jet ventilation of rabbits
    • Frantz, I. D. III, and R. D. Close. Elevated lung volume and alveolar pressure during jet ventilation of rabbits. Am. Rev. Respir. Dis. 131: 134-138, 1985.
    • (1985) Am. Rev. Respir. Dis. , vol.131 , pp. 134-138
    • Frantz I.D. III1    Close, R.D.2
  • 12
    • 0021159431 scopus 로고
    • Alveolar pressure nonhomogeneity during small-amplitude high-frequency oscillation
    • Fredberg, J., D. Keefe, G. Glass, R. Castile, and I. Frantz III. Alveolar pressure nonhomogeneity during small-amplitude high-frequency oscillation. J. Appl. Physiol. 57: 788-800, 1984.
    • (1984) J. Appl. Physiol. , vol.57 , pp. 788-800
    • Fredberg, J.1    Keefe, D.2    Glass, G.3    Castile, R.4    Frantz I. III5
  • 13
    • 0025040482 scopus 로고
    • Proximal, tracheal and alveolar pressures during high-frequency oscillatory ventilation in a normal rabbit model
    • Gerstmann, D., J. Fouke, D. Winter, A. Taylor, and R. deLemos. Proximal, tracheal and alveolar pressures during high-frequency oscillatory ventilation in a normal rabbit model. Pediatr. Res. 28: 367-373, 1990.
    • (1990) Pediatr. Res. , vol.28 , pp. 367-373
    • Gerstmann, D.1    Fouke, J.2    Winter, D.3    Taylor, A.4    Delemos, R.5
  • 14
    • 0031746090 scopus 로고    scopus 로고
    • Mechanical performance of clinically available, neonatal, high-frequency, oscillatory-type ventilators
    • Hatcher, D., H. Watanabe, T. Ashbury, S. Vincent, J. Fisher, and A. Froese. Mechanical performance of clinically available, neonatal, high-frequency, oscillatory-type ventilators. Crit. Care Med. 26: 1081-1088, 1998.
    • (1998) Crit. Care Med. , vol.26 , pp. 1081-1088
    • Hatcher, D.1    Watanabe, H.2    Ashbury, T.3    Vincent, S.4    Fisher, J.5    Froese, A.6
  • 15
    • 0018232361 scopus 로고
    • Effect of parenchymal shear modulus and lung volume on bronchial pressure-diameter behavior
    • Lai Fook, S., R. Hyatt, and J. Rodarte. Effect of parenchymal shear modulus and lung volume on bronchial pressure-diameter behavior. J. Appl. Physiol. 44: 859-868, 1978.
    • (1978) J. Appl. Physiol. , vol.44 , pp. 859-868
    • Lai Fook, S.1    Hyatt, R.2    Rodarte, J.3
  • 16
    • 0021250795 scopus 로고
    • Passive respiratory mechanics in newborns and children
    • LeSouëf, P., S. England, and A. Bryan. Passive respiratory mechanics in newborns and children. Am. Rev. Respir. Dis. 129: 727-729, 1984.
    • (1984) Am. Rev. Respir. Dis. , vol.129 , pp. 727-729
    • LeSouëf, P.1    England, S.2    Bryan, A.3
  • 17
    • 0022633150 scopus 로고
    • Dynamics of expiration and gas trapping in rabbits during mechanical ventilation at rapid rates
    • Pérez Fontán, J., G. Heldt, R. Targett, M. Willis, and G. Gregory. Dynamics of expiration and gas trapping in rabbits during mechanical ventilation at rapid rates. Crit. Care Med. 14: 39-46, 1986.
    • (1986) Crit. Care Med. , vol.14 , pp. 39-46
    • Pérez Fontán, J.1    Heldt, G.2    Targett, R.3    Willis, M.4    Gregory, G.5
  • 18
    • 0023212086 scopus 로고
    • Ventilator settings for newborn infants
    • Ramsden, C., and E. Reynolds. Ventilator settings for newborn infants. Arch. Dis. Child. 62: 529-538, 1987.
    • (1987) Arch. Dis. Child. , vol.62 , pp. 529-538
    • Ramsden, C.1    Reynolds, E.2
  • 20
    • 0022623539 scopus 로고
    • Inadvertent positive end expiratory pressure in mechanically ventilated newborn infants: Detection and effect on lung mechanics and gas exchange
    • Simbruner, G. Inadvertent positive end expiratory pressure in mechanically ventilated newborn infants: detection and effect on lung mechanics and gas exchange. J. Pediatr. 108: 589-595, 1986.
    • (1986) J. Pediatr. , vol.108 , pp. 589-595
    • Simbruner, G.1
  • 21
    • 0021681705 scopus 로고
    • Mean airway pressure and alveolar pressure during high-frequency ventilation
    • Simon, B., G. Weinmann, and W. Mitzner. Mean airway pressure and alveolar pressure during high-frequency ventilation. J. Appl. Physiol. 57: 1069-1078, 1984.
    • (1984) J. Appl. Physiol. , vol.57 , pp. 1069-1078
    • Simon, B.1    Weinmann, G.2    Mitzner, W.3
  • 22
    • 0023776976 scopus 로고
    • Noninvasive determination of respiratory mechanics during mechanical ventilation of neonates
    • Sly, P., K. Brown, J. Bates, S. Spier, J. Milic-Emili. Noninvasive determination of respiratory mechanics during mechanical ventilation of neonates. Pediatr. Pulmonol. 4: 39-47, 1987.
    • (1987) Pediatr. Pulmonol. , vol.4 , pp. 39-47
    • Sly, P.1    Brown, K.2    Bates, J.3    Spier, S.4    Milic-Emili, J.5
  • 23
    • 0022531302 scopus 로고
    • Expiratory flow limitation and dynamic pulmonary hyperinflation during high-frequency ventilation
    • Solway, J., T. Rossing, A. Saari, and J. Drazen. Expiratory flow limitation and dynamic pulmonary hyperinflation during high-frequency ventilation. J. Appl. Physiol. 60: 2071-2078, 1986.
    • (1986) J. Appl. Physiol. , vol.60 , pp. 2071-2078
    • Solway, J.1    Rossing, T.2    Saari, A.3    Drazen, J.4
  • 24
    • 0021934173 scopus 로고
    • Single-breath measurement of lung mechanics in very low birth weight infants
    • Thomson, A., and M. Silverman. Single-breath measurement of lung mechanics in very low birth weight infants. Crit. Care Med. 13: 4-8, 1985.
    • (1985) Crit. Care Med. , vol.13 , pp. 4-8
    • Thomson, A.1    Silverman, M.2
  • 25
    • 0028523659 scopus 로고
    • Proximal and tracheal airway pressures during different modes of mechanical ventilation: An animal model study
    • Zobel, G., D. Dacar, and S. Rödl. Proximal and tracheal airway pressures during different modes of mechanical ventilation: an animal model study. Pediatr. Pulmonol. 18: 239-243, 1994.
    • (1994) Pediatr. Pulmonol. , vol.18 , pp. 239-243
    • Zobel, G.1    Dacar, D.2    Rödl, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.