메뉴 건너뛰기




Volumn 24, Issue 4, 1999, Pages 287-294

A comparison of 18-MV and 6-MV treatment plans using 3D dose calculation with and without heterogeneity correction

Author keywords

18 MV x rays; Breast dosimetry; Heterogeneity corrections; Three dimensional treatment planning

Indexed keywords

ARTICLE; BREAST CANCER; CANCER RADIOTHERAPY; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DOSIMETRY; FEMALE; HUMAN; IRRADIATION; PRIORITY JOURNAL; RADIATION DOSE DISTRIBUTION; STANDARD; TREATMENT PLANNING;

EID: 0032776244     PISSN: 09583947     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0958-3947(99)00022-9     Document Type: Article
Times cited : (6)

References (6)
  • 1
    • 0028576881 scopus 로고
    • The influence of breast size on late radiation effects and association with radiotherapy dose inhomogeneity
    • Moody A.M., Mayles W.P.M., Bliss J.M., et al. The influence of breast size on late radiation effects and association with radiotherapy dose inhomogeneity. Radiother. Oncol. 33:1994;106-112.
    • (1994) Radiother. Oncol. , vol.33 , pp. 106-112
    • Moody, A.M.1    Mayles, W.P.M.2    Bliss, J.M.3
  • 3
    • 0028915422 scopus 로고
    • Correlation of breast dose heterogeneity with breast size using 3D CT planning and dose-volume histograms
    • Neal A.J., Torr M., Helyer S., Yarnold J.R. Correlation of breast dose heterogeneity with breast size using 3D CT planning and dose-volume histograms. Radiother. Oncol. 34:1995;210-218.
    • (1995) Radiother. Oncol. , vol.34 , pp. 210-218
    • Neal, A.J.1    Torr, M.2    Helyer, S.3    Yarnold, J.R.4
  • 5
    • 0029318628 scopus 로고
    • Use of a lucite beam spoiler for high-energy breast irradiation
    • Klein E.E., Michalet-Lorenz M., Taylor M.E. Use of a lucite beam spoiler for high-energy breast irradiation. Med. Dosim. 20:1995;89-94.
    • (1995) Med. Dosim. , vol.20 , pp. 89-94
    • Klein, E.E.1    Michalet-Lorenz, M.2    Taylor, M.E.3
  • 6
    • 0030661598 scopus 로고    scopus 로고
    • Conservative surgery and radiotherapy for early-stage breast cancer using a lung density correction: The University of Michigan experience
    • Pierce L.J., Stawderman M.H., Douglas K.R., Lichter A.S. Conservative surgery and radiotherapy for early-stage breast cancer using a lung density correction the University of Michigan experience . Int. J. Radiat. Oncol. Biol. Phys. 39:1997;921-928.
    • (1997) Int. J. Radiat. Oncol. Biol. Phys. , vol.39 , pp. 921-928
    • Pierce, L.J.1    Stawderman, M.H.2    Douglas, K.R.3    Lichter, A.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.