메뉴 건너뛰기




Volumn 34, Issue 8, 1999, Pages 530-535

Endovascular Doppler guide wire in renal arteries: Correlation with angiography in 20 patients

Author keywords

Renal arteries, flow dynamics; Renal arteries, stenosis or obstruction; Ultrasound, Doppler studies; Ultrasound, intravascular

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CORRELATION FUNCTION; DOPPLER ECHOGRAPHY; FEMALE; GUIDE WIRE; HUMAN; KIDNEY ANGIOGRAPHY; KIDNEY ARTERY STENOSIS; MALE; PRIORITY JOURNAL;

EID: 0032768590     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004424-199908000-00006     Document Type: Article
Times cited : (11)

References (14)
  • 1
    • 0026700804 scopus 로고
    • Doppler US evaluation of renal artery stenosis: Past, present and future
    • Middleton WD. Doppler US evaluation of renal artery stenosis: Past, present and future. Radiology 1992;184:307-308.
    • (1992) Radiology , vol.184 , pp. 307-308
    • Middleton, W.D.1
  • 2
    • 0025250742 scopus 로고
    • Renal artery stenosis: Evaluation with color Doppler flow imaging
    • Desberg AL, Paushter DN, Lammert GK, et al. Renal artery stenosis: Evaluation with color Doppler flow imaging. Radiology 1990;177: 749-753.
    • (1990) Radiology , vol.177 , pp. 749-753
    • Desberg, A.L.1    Paushter, D.N.2    Lammert, G.K.3
  • 3
    • 0029022453 scopus 로고
    • Renal artery stenosis: Should we study the main renal artery or segmental vessels?
    • Halpern EJ, Needelman L, Nack T. Renal artery stenosis: Should we study the main renal artery or segmental vessels? Radiology 1995; 195:799-804.
    • (1995) Radiology , vol.195 , pp. 799-804
    • Halpern, E.J.1    Needelman, L.2    Nack, T.3
  • 4
    • 0027435076 scopus 로고
    • Renal artery stenosis: Analysis of Doppler waveform parameters and tardus-parvus pattern
    • Kliewer MA, Cuppler RH, Carroll BA, et al. Renal artery stenosis: Analysis of Doppler waveform parameters and tardus-parvus pattern. Radiology 1993;189:779-787.
    • (1993) Radiology , vol.189 , pp. 779-787
    • Kliewer, M.A.1    Cuppler, R.H.2    Carroll, B.A.3
  • 5
    • 0026773929 scopus 로고
    • Segmental stenosis of the renal arteries: Pattern recognition of tardus and parvus abnormalities with duplex sonography
    • Stavros AT, Parker SH, Yakes WF, et al. Segmental stenosis of the renal arteries: Pattern recognition of tardus and parvus abnormalities with duplex sonography. Radiology 1992;184:487-492.
    • (1992) Radiology , vol.184 , pp. 487-492
    • Stavros, A.T.1    Parker, S.H.2    Yakes, W.F.3
  • 6
    • 0024334548 scopus 로고
    • Doppler waveform parvus and tardus: A sign of proximal flow obstruction
    • Kotval PS. Doppler waveform parvus and tardus: A sign of proximal flow obstruction. J Ultrasound Med 1989;8:435-440.
    • (1989) J Ultrasound Med , vol.8 , pp. 435-440
    • Kotval, P.S.1
  • 7
    • 0027865503 scopus 로고
    • Clinical applications of the Doppler coronary flow velocity guidewire for interventional procedures
    • Kern MJ, Donohue TJ, Bach RG, et al. Clinical applications of the Doppler coronary flow velocity guidewire for interventional procedures. J Interv Cardiol 1993;6:345-363.
    • (1993) J Interv Cardiol , vol.6 , pp. 345-363
    • Kern, M.J.1    Donohue, T.J.2    Bach, R.G.3
  • 8
    • 0030007579 scopus 로고    scopus 로고
    • Renal artery stenosis: Endovascular Flowire study for validation of Doppler US
    • Van Der Hulst VPM, Van Baalen J, Schultze Kool L, et al. Renal artery stenosis: Endovascular Flowire study for validation of Doppler US. Radiology 1996;200:165-168.
    • (1996) Radiology , vol.200 , pp. 165-168
    • Van Der Hulst, V.P.M.1    Van Baalen, J.2    Schultze Kool, L.3
  • 9
    • 0026504959 scopus 로고
    • Validation of Doppler guide wire for intravascular measurement of coronary artery flow velocity
    • Doucette JW, Corl PD, Payne HM. Validation of Doppler guide wire for intravascular measurement of coronary artery flow velocity. Circulation 1992;85:1894-1911.
    • (1992) Circulation , vol.85 , pp. 1894-1911
    • Doucette, J.W.1    Corl, P.D.2    Payne, H.M.3
  • 10
    • 0017330521 scopus 로고
    • Hemodynamic effects of controlled degrees of coronary artery stenosis in short-term and long-term studies in dogs
    • Folts JD, Gallagher K. Hemodynamic effects of controlled degrees of coronary artery stenosis in short-term and long-term studies in dogs. J Thorac Cardiovasc Surg 1977;73:722-727.
    • (1977) J Thorac Cardiovasc Surg , vol.73 , pp. 722-727
    • Folts, J.D.1    Gallagher, K.2
  • 11
    • 0027300391 scopus 로고
    • Combined physiologic and anatomic assessment of percutaneous revascularization using a Doppler guide wire and ultrasound catheter
    • Isner JM, Kaufman J, Rosenfield K. Combined physiologic and anatomic assessment of percutaneous revascularization using a Doppler guide wire and ultrasound catheter. Am J Cardiol 1993;71:70D-86D.
    • (1993) Am J Cardiol , vol.71
    • Isner, J.M.1    Kaufman, J.2    Rosenfield, K.3
  • 12
    • 84993844414 scopus 로고
    • Combined intravascular ultrasound and intravascular Doppler wire provide complementary anatomic and physiologic imaging during percutaneous revascularization
    • Kaufman J, Rosenfield KA, Pieczek A. Combined intravascular ultrasound and intravascular Doppler wire provide complementary anatomic and physiologic imaging during percutaneous revascularization J Am Coll Cardiol 1992;19:293A.
    • (1992) J Am Coll Cardiol , vol.19
    • Kaufman, J.1    Rosenfield, K.A.2    Pieczek, A.3
  • 13
    • 0025321236 scopus 로고
    • Percutaneous intravascular US has adjunct to catheter-based interventions: Preliminary experience in patients with peripheral vascular disease
    • Isner JM, Rosenfield K, Losordo DW. Percutaneous intravascular US has adjunct to catheter-based interventions: Preliminary experience in patients with peripheral vascular disease. Radiology 1990;175: 61-70.
    • (1990) Radiology , vol.175 , pp. 61-70
    • Isner, J.M.1    Rosenfield, K.2    Losordo, D.W.3
  • 14
    • 84993884562 scopus 로고
    • Intra-arterial Doppler flow measurement during renal artery endovascular stent deployment: Abolition of resting impedance to blood flow
    • Bates MC, Dorros G, Kumar K. Intra-arterial Doppler flow measurement during renal artery endovascular stent deployment: Abolition of resting impedance to blood flow. J Interv Cardiol 1994;7:199-202.
    • (1994) J Interv Cardiol , vol.7 , pp. 199-202
    • Bates, M.C.1    Dorros, G.2    Kumar, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.