Volumn 73, Issue 6, 1999, Pages 307-310

Determination of fluoride in toothpaste, effluent streams and natural and borehole water using a flow injection system with a fluoride-selective membrane electrode

Author keywords

Flow injection analysis; Fluoride selective membrane electrode

Indexed keywords

FLUORIDE; TOOTHPASTE;

EID: 0032767491     PISSN: 00316865     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0031-6865(99)00008-4     Document Type: Article
Times cited : (21)

References (10)
  • 1
    • 0011053414 scopus 로고
    • Flow cell with double slope factor for potentiometric determination of fluoride at low concentrations
    • Borzitsky J.A., Dvinin A., Petrukhin O.M., Urosov Y.I. Flow cell with double slope factor for potentiometric determination of fluoride at low concentrations. Analyst. 118:1993;859-861.
    • (1993) Analyst , vol.118 , pp. 859-861
    • Borzitsky, J.A.1    Dvinin, A.2    Petrukhin, O.M.3    Urosov, Y.I.4
  • 2
    • 0001524048 scopus 로고
    • Buffer systems for use with the fluoride electrode in flow injection analysis
    • Cardwell T.J., Cattrall R.W., Hausen P.C., Hamilton I.C. Buffer systems for use with the fluoride electrode in flow injection analysis. Anal. Chem. 59:1987;206-208.
    • (1987) Anal. Chem. , vol.59 , pp. 206-208
    • Cardwell, T.J.1    Cattrall, R.W.2    Hausen, P.C.3    Hamilton, I.C.4
  • 3
    • 0344619948 scopus 로고
    • The Analysis of water in environmental analytical chemistry
    • In: Fifield, F.W., Haines, P.J. (Eds.), Chapman & Hall, London, UK
    • Fifield, F.W., 1995. The Analysis of water in environmental analytical chemistry. In: Fifield, F.W., Haines, P.J. (Eds.), P-367. Blackie Academic and Professional, Chapman & Hall, London, UK.
    • (1995) P-367. Blackie Academic and Professional
    • Fifield, F.W.1
  • 4
    • 0000214264 scopus 로고
    • The fluoride ion-selective electrode in flow injection analysis: Part I. General methodology
    • Frenzel W., Brätter P. The fluoride ion-selective electrode in flow injection analysis: Part I. General methodology. Anal. Chim. Acta. 185:1986;127-136.
    • (1986) Anal. Chim. Acta , vol.185 , pp. 127-136
    • Frenzel, W.1    Brätter, P.2
  • 5
    • 0031562070 scopus 로고    scopus 로고
    • Buffer composition suitable for determining very low fluoride concentrations using a fluoride ion-selective electrode and its application to the continuous analysis of rain water
    • Hara H., Huang C.C. Buffer composition suitable for determining very low fluoride concentrations using a fluoride ion-selective electrode and its application to the continuous analysis of rain water. Anal. Chim. Acta. 338:1997;141-147.
    • (1997) Anal. Chim. Acta. , vol.338 , pp. 141-147
    • Hara, H.1    Huang, C.C.2
  • 6
    • 0026835065 scopus 로고
    • Computer-aided flow-analysis for laboratory use and process analysis
    • Marshall G.D., van Staden J.F. Computer-aided flow-analysis for laboratory use and process analysis. Anal. Instrum. 20:1992;79-100.
    • (1992) Anal. Instrum. , vol.20 , pp. 79-100
    • Marshall, G.D.1    Van Staden, J.F.2
  • 7
    • 0002852450 scopus 로고
    • Simultaneous determination of chloride, bromide, iodide and fluoride with flow injection/ion-selective electrode systems
    • Najib F.M., Othman S. Simultaneous determination of chloride, bromide, iodide and fluoride with flow injection/ion-selective electrode systems. Talanta. 39:1992;1259-1267.
    • (1992) Talanta , vol.39 , pp. 1259-1267
    • Najib, F.M.1    Othman, S.2
  • 8
    • 0002614636 scopus 로고
    • The use of ion-selective electrodes in manual and computer-controlled flow injection systems
    • Slanina J., Lingerak W.A., Bakker F. The use of ion-selective electrodes in manual and computer-controlled flow injection systems. Anal. Chim. Acta. 117:1980;91-98.
    • (1980) Anal. Chim. Acta , vol.117 , pp. 91-98
    • Slanina, J.1    Lingerak, W.A.2    Bakker, F.3
  • 9
    • 0001776981 scopus 로고
    • Limitation of linear response in flow-injection systems with ion-selective electrodes
    • Trojanowicz M., Matuszewski W. Limitation of linear response in flow-injection systems with ion-selective electrodes. Anal. Chim. Acta. 138:1982;71-79.
    • (1982) Anal. Chim. Acta , vol.138 , pp. 71-79
    • Trojanowicz, M.1    Matuszewski, W.2
  • 10
    • 0023338262 scopus 로고
    • Flow injection determination of inorganic bromide in soils with a coated tubular solid-state bromide-selective electrode
    • van Staden J.F. Flow injection determination of inorganic bromide in soils with a coated tubular solid-state bromide-selective electrode. Analyst. 112:1987;595-599.
    • (1987) Analyst , vol.112 , pp. 595-599
    • Van Staden, J.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.