Volumn 60, Issue 3, 1999, Pages 155-160

Analysis of client characteristics that may affect early discontinuation of the TCu-380A IUD

Author keywords

Discontinuation reasons; Life table rates; TCu 380A IUD

Indexed keywords

COPPER INTRAUTERINE DEVICE;

EID: 0032763851     PISSN: 00107824     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0010-7824(99)00077-3     Document Type: Article
Times cited : (62)

References (20)
  • 2
    • 0001433463 scopus 로고
    • IUD use throughout the world: Past, present, and future
    • C.W. Bardin, & D.R. Jr. Mishell. Boston: Butterworth-Heinemann
    • Mauldin W.P., Segal S.J. IUD use throughout the world past, present, and future . Bardin C.W., Mishell D.R. Jr. Proceedings from the Fourth International Conference on IUDs. 1994;1-10 Butterworth-Heinemann, Boston.
    • (1994) Proceedings from the Fourth International Conference on IUDs , pp. 1-10
    • Mauldin, W.P.1    Segal, S.J.2
  • 6
    • 0006772838 scopus 로고    scopus 로고
    • Long-term reversible contraception: Twelve years of experience with the TCu-380A and TCu 220C
    • Long-term reversible contraception twelve years of experience with the TCu-380A and TCu 220C . Contraception. 56:1997;341-352.
    • (1997) Contraception , vol.56 , pp. 341-352
  • 7
    • 0344973664 scopus 로고    scopus 로고
    • Intrauterine devices: Mechanisms of action, safety, and efficacy
    • Mishell D.R. Jr. Intrauterine devices mechanisms of action, safety, and efficacy . Contraception. 58:1998;45S-53S.
    • (1998) Contraception , vol.58
    • Mishell D.R., Jr.1
  • 8
    • 0031649492 scopus 로고    scopus 로고
    • Twelve-month comparative multicenter study of the TCu-380A and ML 250 intrauterine devices in Bangkok, Thailand
    • Reinprayoon D., Gilmore C., Farr G., Amatya R. Twelve-month comparative multicenter study of the TCu-380A and ML 250 intrauterine devices in Bangkok, Thailand. Contraception. 58:1998;201-206.
    • (1998) Contraception , vol.58 , pp. 201-206
    • Reinprayoon, D.1    Gilmore, C.2    Farr, G.3    Amatya, R.4
  • 9
    • 0027178721 scopus 로고
    • Factors associated with Copper T IUD removal for bleeding/pain: A multivariate analysis
    • Zhang J. Factors associated with Copper T IUD removal for bleeding/pain a multivariate analysis . Contraception. 48:1993;13-21.
    • (1993) Contraception , vol.48 , pp. 13-21
    • Zhang, J.1
  • 10
    • 0028003874 scopus 로고
    • An analysis of the personal reasons for discontinuing IUD use
    • Petta C., Amatya R., Farr G., Chi I-c. An analysis of the personal reasons for discontinuing IUD use. Contraception. 50:1994;339-347.
    • (1994) Contraception , vol.50 , pp. 339-347
    • Petta, C.1    Amatya, R.2    Farr, G.3    Chi, I.-C.4
  • 11
    • 0024374892 scopus 로고
    • Performance of the Copper T-380A intrauterine device in breastfeeding women
    • Chi I-c, Potts M., Wilkens L.R., Champion C.B. Performance of the Copper T-380A intrauterine device in breastfeeding women. Contraception. 39:1989;603-618.
    • (1989) Contraception , vol.39 , pp. 603-618
    • Chi, I.-C.1    Potts, M.2    Wilkens, L.R.3    Champion, C.B.4
  • 12
    • 0024240782 scopus 로고
    • A three-year evaluation of TCu-380Ag and Multiload Cu 375 intrauterine devices
    • Champion C., Behilovic B., Arosemena J., Randic L., et al. A three-year evaluation of TCu-380Ag and Multiload Cu 375 intrauterine devices. Contraception. 38:1988;631-639.
    • (1988) Contraception , vol.38 , pp. 631-639
    • Champion, C.1    Behilovic, B.2    Arosemena, J.3    Randic, L.4
  • 13
    • 0027064740 scopus 로고
    • Evaluation of the performance of the Copper T 380A IUD up to ten years. Is this IUD a reversible but potentially permanent method?
    • Diaz J., Bahamondes L., Diaz M., Marchi N., Faundes A., Marini M. Evaluation of the performance of the Copper T 380A IUD up to ten years. Is this IUD a reversible but potentially permanent method? Adv Contracept. 8:1992;275-280.
    • (1992) Adv Contracept , vol.8 , pp. 275-280
    • Diaz, J.1    Bahamondes, L.2    Diaz, M.3    Marchi, N.4    Faundes, A.5    Marini, M.6
  • 14
    • 0025746608 scopus 로고
    • Prolonged intrauterine contraception: A seven-year randomized study of the levonorgestrel 20 mcg/day (LNg 20) and the Copper T 380 Ag IUDs
    • Sivin I., Stern J., Coutinho E., et al. Prolonged intrauterine contraception a seven-year randomized study of the levonorgestrel 20 mcg/day (LNg 20) and the Copper T 380 Ag IUDs . Contraception. 44:1991;473-480.
    • (1991) Contraception , vol.44 , pp. 473-480
    • Sivin, I.1    Stern, J.2    Coutinho, E.3
  • 15
    • 0026481222 scopus 로고
    • Risk factors for copper T IUD expulsion: An epidemiologic analysis
    • Zhang J., Feldblum P., Chi I-c, Farr G. Risk factors for copper T IUD expulsion an epidemiologic analysis . Contraception. 46:1992;427-433.
    • (1992) Contraception , vol.46 , pp. 427-433
    • Zhang, J.1    Feldblum, P.2    Chi, I.-C.3    Farr, G.4
  • 16
    • 0021080662 scopus 로고
    • Five years' experience of intrauterine contraception with the Nova-T and the Copper T 200
    • Luukkainen T., Allonen H., Nielsen N.C., Nygren K.G., Pyörälä T. Five years' experience of intrauterine contraception with the Nova-T and the Copper T 200. Am J Obstet Gynecol. 147:1983;885-892.
    • (1983) Am J Obstet Gynecol , vol.147 , pp. 885-892
    • Luukkainen, T.1    Allonen, H.2    Nielsen, N.C.3    Nygren, K.G.4    Pyörälä, T.5
  • 18
    • 0016230677 scopus 로고
    • Two years experience with Copper T 200 in a Swedish population: A comparison between nulliparous and parous women
    • Liedholm P., Sjöberg N.O. Two years experience with Copper T 200 in a Swedish population a comparison between nulliparous and parous women . Contraception. 10:1974;55-61.
    • (1974) Contraception , vol.10 , pp. 55-61
    • Liedholm, P.1    Sjöberg, N.O.2
  • 20
    • 0026625210 scopus 로고
    • Interactions between intrauterine contraceptive device use and breast-feeding status at the time of intrauterine contraceptive device insertion: Analysis of TCu-380A acceptors in developing countries
    • Farr G., Rivera R. Interactions between intrauterine contraceptive device use and breast-feeding status at the time of intrauterine contraceptive device insertion analysis of TCu-380A acceptors in developing countries . Am J Obstet Gynecol. 167:1992;144-151.
    • (1992) Am J Obstet Gynecol , vol.167 , pp. 144-151
    • Farr, G.1    Rivera, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.