메뉴 건너뛰기




Volumn 87, Issue 6, 1999, Pages 2266-2273

Noninvasive cardiac output measurement in orthostasis: Pulse contour analysis compared with acetylene rebreathing

Author keywords

Blood pressure; Finapres; Standing; Stroke volume; Tilt

Indexed keywords

ACETYLENE;

EID: 0032763347     PISSN: 87507587     EISSN: None     Source Type: Journal    
DOI: 10.1152/jappl.1999.87.6.2266     Document Type: Article
Times cited : (18)

References (25)
  • 1
    • 0015395292 scopus 로고
    • Evaluation of the pulse-contour method of determining stroke volume in man
    • Alderman, E. L., A. Branzi, W. Sanders, B. W. Brown, and D. C. Harrison. Evaluation of the pulse-contour method of determining stroke volume in man. Circulation 46: 546-558, 1972.
    • (1972) Circulation , vol.46 , pp. 546-558
    • Alderman, E.L.1    Branzi, A.2    Sanders, W.3    Brown, B.W.4    Harrison, D.C.5
  • 2
    • 0024385063 scopus 로고
    • Influence of mean pressure on aortic impedance and reflections in the systemic arterial system
    • Heart Circ. Physiol. 26
    • Alexander, J., Jr., D. Burkhoff, J. Schipke, and K. Sagawa. Influence of mean pressure on aortic impedance and reflections in the systemic arterial system. Am. J. Physiol. 257 (Heart Circ. Physiol. 26): H969-H978, 1989.
    • (1989) Am. J. Physiol. , vol.257
    • Alexander J., Jr.1    Burkhoff, D.2    Schipke, J.3    Sagawa, K.4
  • 3
    • 0026510983 scopus 로고
    • Head-down tilt bedrest. HDT'88-an international collaborative effort in integrated systems physiology
    • Baisch, F., L. Beck, J. M. Karemaker, P. Arbeille, F. A. Gaffhey, and C. G. Blomqvist. Head-down tilt bedrest. HDT'88-an international collaborative effort in integrated systems physiology. Acta Physiol. Scand. Suppl. 604: 1-12, 1992.
    • (1992) Acta Physiol. Scand. Suppl. , vol.604 , pp. 1-12
    • Beck, L.1    Karemaker, J.M.2    Arbeille, P.3    Gaffhey, F.A.4    Blomqvist, C.G.5
  • 4
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland, J. M., and D. G. Altman. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1: 307-310, 1986.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 5
    • 0020598227 scopus 로고
    • Pulmonary blood flow and tissue volume: Model analysis of rebreathing estimation methods
    • Burma, G. M., and G. M. Saidel. Pulmonary blood flow and tissue volume: model analysis of rebreathing estimation methods. J. Appl. Physiol. 55: 205-211, 1983.
    • (1983) J. Appl. Physiol. , vol.55 , pp. 205-211
    • Burma, G.M.1    Saidel, G.M.2
  • 6
    • 0021343419 scopus 로고
    • Effect of ventilation and perfusion imbalance on inert gas rebreathing variables
    • Friedman, M., S. A. Wilkins, Jr., A. F. Rothfeld, and P. A. Bromberg. Effect of ventilation and perfusion imbalance on inert gas rebreathing variables. J. Appl. Physiol. 56: 364-369, 1984.
    • (1984) J. Appl. Physiol. , vol.56 , pp. 364-369
    • Friedman, M.1    Wilkins S.A., Jr.2    Rothfeld, A.F.3    Bromberg, P.A.4
  • 8
    • 0019995350 scopus 로고
    • Pulmonary blood flow, diffusing, capacity and tissue volume by rebreathing: Theory
    • Hook, C., and M. Meyer. Pulmonary blood flow, diffusing, capacity and tissue volume by rebreathing: theory. Respir. Physiol. 48: 255-279, 1982.
    • (1982) Respir. Physiol. , vol.48 , pp. 255-279
    • Hook, C.1    Meyer, M.2
  • 9
    • 85047676115 scopus 로고
    • Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure
    • Imholz, B. P., J. J. Settels, A. H. van der Meiracker, K. H. Wesseling, and W. Wieling. Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure. Cardiovasc. Res. 24: 214-221, 1990.
    • (1990) Cardiovasc. Res. , vol.24 , pp. 214-221
    • Imholz, B.P.1    Settels, J.J.2    Van Der Meiracker, A.H.3    Wesseling, K.H.4    Wieling, W.5
  • 10
    • 0025650019 scopus 로고
    • Continuous cardiac output monitoring by pulse contour during cardiac surgery
    • Jansen, J. R., K. H. Wesseling, J. J. Settels, and J. J. Schreuder. Continuous cardiac output monitoring by pulse contour during cardiac surgery. Eur. Heart J. 11, Suppl. I: 26-32, 1990.
    • (1990) Eur. Heart J. , vol.11 , Issue.SUPPL. I , pp. 26-32
    • Jansen, J.R.1    Wesseling, K.H.2    Settels, J.J.3    Schreuder, J.J.4
  • 11
    • 0029736631 scopus 로고    scopus 로고
    • Finger arterial versus intrabrachial pressure and continuous cardiac output during head-up tilt testing in healthy subjects
    • Jellema, W. T., B. P. Imholz, J. van Goudoever, K. H. Wesseling, and J. J. van Lieshout. Finger arterial versus intrabrachial pressure and continuous cardiac output during head-up tilt testing in healthy subjects. Clin. Sci. (Colch.) 91: 193-200, 1996.
    • (1996) Clin. Sci. (Colch.) , vol.91 , pp. 193-200
    • Jellema, W.T.1    Imholz, B.P.2    Van Goudoever, J.3    Wesseling, K.H.4    Van Lieshout, J.J.5
  • 12
    • 0022338143 scopus 로고
    • Regional wave travel and reflections along the human aorta: A study with six simultaneous micromanometric pressures
    • Latham, R. D., N. Westerhof, P. Sipkema, B. J. Rubal, P. Reuderink, and J. P. Murgo. Regional wave travel and reflections along the human aorta: a study with six simultaneous micromanometric pressures. Circulation 72: 1257-1269, 1985.
    • (1985) Circulation , vol.72 , pp. 1257-1269
    • Latham, R.D.1    Westerhof, N.2    Sipkema, P.3    Rubal, B.J.4    Reuderink, P.5    Murgo, J.P.6
  • 13
    • 0004277713 scopus 로고
    • Baltimore, MD: Williams & Wilkins, 309, 351, 392
    • McDonald, D. A. Blood Flow in Arteries. Baltimore, MD: Williams & Wilkins, 1974, p. 254, 309, 351, 392.
    • (1974) Blood Flow in Arteries , pp. 254
    • McDonald, D.A.1
  • 14
    • 0019352211 scopus 로고
    • Manipulation of ascending aortic pressure and flow wave reflections with the Valsalva maneuver: Relationship to input impedance
    • Murgo, J. P., N. Westerhof, J. P. Giolma, and S. A. Altobelli. Manipulation of ascending aortic pressure and flow wave reflections with the Valsalva maneuver: relationship to input impedance. Circulation 63: 122-132, 1981.
    • (1981) Circulation , vol.63 , pp. 122-132
    • Murgo, J.P.1    Westerhof, N.2    Giolma, J.P.3    Altobelli, S.A.4
  • 15
    • 0002220170 scopus 로고
    • Photoelectric measurement of blood pressure, volume and flow in the finger
    • Peñáz, J. Photoelectric measurement of blood pressure, volume and flow in the finger (Abstract). Dig. Int. Conf. Med. Biol. Eng. 104, 1973.
    • (1973) Dig. Int. Conf. Med. Biol. Eng. , pp. 104
    • Peñáz, J.1
  • 16
    • 0018243356 scopus 로고
    • Lung tissue volume and blood flow by rebreathing theory
    • Petrini, M. F., B. T. Peterson, and R. W. Hyde. Lung tissue volume and blood flow by rebreathing theory. J. Appl. Physiol. 44: 795-802, 1978.
    • (1978) J. Appl. Physiol. , vol.44 , pp. 795-802
    • Petrini, M.F.1    Peterson, B.T.2    Hyde, R.W.3
  • 17
    • 0015808024 scopus 로고
    • Evaluation of several methods for computing stroke volume from central aortic pressure
    • Starmer, C. F., P. A. McHale, F. R. Cobb, and J. C. Greenfield, Jr. Evaluation of several methods for computing stroke volume from central aortic pressure. Circ. Res. 33: 139-148, 1973.
    • (1973) Circ. Res. , vol.33 , pp. 139-148
    • Starmer, C.F.1    McHale, P.A.2    Cobb, F.R.3    Greenfield J.C., Jr.4
  • 18
    • 0027176837 scopus 로고
    • Noninvasive cardiac output measurement by arterial pulse analysis compared with inert gas rebreathing
    • Stok, W. J., F. Baisch, A. Hillebrecht, H. Schulz, M. Meyer, and J. M. Karemaker. Noninvasive cardiac output measurement by arterial pulse analysis compared with inert gas rebreathing. J. Appl. Physiol. 74: 2687-2693, 1993.
    • (1993) J. Appl. Physiol. , vol.74 , pp. 2687-2693
    • Stok, W.J.1    Baisch, F.2    Hillebrecht, A.3    Schulz, H.4    Meyer, M.5    Karemaker, J.M.6
  • 19
    • 0020605062 scopus 로고
    • Evaluation of pulse contour methods in calculating stroke volume from pulmonary artery pressure curve (comparison with aortic pressure curve)
    • Tajimi, T., K. Sunagawa, A. Yamada, Y. Nose, A. Takeshita, Y. Kikuchi, and M. Nakamura. Evaluation of pulse contour methods in calculating stroke volume from pulmonary artery pressure curve (comparison with aortic pressure curve). Eur. Heart J. 4: 502-511, 1983.
    • (1983) Eur. Heart J. , vol.4 , pp. 502-511
    • Tajimi, T.1    Sunagawa, K.2    Yamada, A.3    Nose, Y.4    Takeshita, A.5    Kikuchi, Y.6    Nakamura, M.7
  • 20
    • 0027993063 scopus 로고
    • Effects of leg muscle pumping and tensing on orthostatic arterial pressure: A study in normal subjects and patients with autonomic failure
    • Ten Harkel, A. D., J. J. van Lieshout, and W. Wieling. Effects of leg muscle pumping and tensing on orthostatic arterial pressure: a study in normal subjects and patients with autonomic failure. Clin. Sci. (Colch.) 87: 553-558, 1994.
    • (1994) Clin. Sci. (Colch.) , vol.87 , pp. 553-558
    • Ten Harkel, A.D.1    Van Lieshout, J.J.2    Wieling, W.3
  • 21
    • 0027977033 scopus 로고
    • Theoretical basis for time O correction in the rebreathing analysis
    • Verbanck, S., and M. Paiva. Theoretical basis for time O correction in the rebreathing analysis. J. Appl. Physiol. 76: 445-454, 1994.
    • (1994) J. Appl. Physiol. , vol.76 , pp. 445-454
    • Verbanck, S.1    Paiva, M.2
  • 22
    • 0000931633 scopus 로고
    • Finapres, continuous noninvasive finger arterial pressure based on the method of Peñáz
    • W. Meyer-Sabellek, M. Anlauf, R. Gotzen, and L. Steinfeld. Darmstadt, Germany: Steinkopff Verlag
    • Wesseling, K. H. Finapres, continuous noninvasive finger arterial pressure based on the method of Peñáz. In: Blood Pressure Measurement, edited by W. Meyer-Sabellek, M. Anlauf, R. Gotzen, and L. Steinfeld. Darmstadt, Germany: Steinkopff Verlag, 1990, p. 161-172.
    • (1990) Blood Pressure Measurement , pp. 161-172
    • Wesseling, K.H.1
  • 23
    • 0002765004 scopus 로고
    • A simple device for the continuous measurement of cardiac output. Its model basis and experimental verification
    • Wesseling, K. H., B. De Wit, J. A. P. Weber, and N. T. Smith. A simple device for the continuous measurement of cardiac output. Its model basis and experimental verification. Adv. Cardiol. Phys. 5, Suppl. II: 16-52, 1983.
    • (1983) Adv. Cardiol. Phys. , vol.5 , Issue.SUPPL. II , pp. 16-52
    • Wesseling, K.H.1    De Wit, B.2    Weber, J.A.P.3    Smith, N.T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.