Volumn 45, Issue 3, 1999, Pages 204-210

Electric analog model of the aortic valve for calculation of continuous beat-to-beat aortic flow using a pressure gradient

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD VESSELS; CARDIOVASCULAR SURGERY; DIFFERENTIAL EQUATIONS; ELECTRONIC MEDICAL EQUIPMENT; FLOW MEASUREMENT; HEMODYNAMICS; LEAST SQUARES APPROXIMATIONS; MATHEMATICAL MODELS; SPECTRUM ANALYSIS;

EID: 0032762384     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/00002480-199905000-00019     Document Type: Article
Times cited : (4)

References (10)
  • 1
    • 0028874250 scopus 로고
    • Accuracy of disposable blood pressure transducers used in the critical care setting
    • Bailey RH, Bauer JH, Yanos J: Accuracy of disposable blood pressure transducers used in the critical care setting. Crit Care Med 23: 187-192, 1995.
    • (1995) Crit Care Med , vol.23 , pp. 187-192
    • Bailey, R.H.1    Bauer, J.H.2    Yanos, J.3
  • 3
    • 0022556187 scopus 로고
    • Quantification and simulation of fluid-filled catheter/transducer systems
    • Taylor BC, Ellis DM, Drew JM: Quantification and simulation of fluid-filled catheter/transducer systems. Med Instr 20: 123-129, 1986.
    • (1986) Med Instr , vol.20 , pp. 123-129
    • Taylor, B.C.1    Ellis, D.M.2    Drew, J.M.3
  • 4
    • 0026808319 scopus 로고
    • Pressure wave fidelity in catheter introducers
    • Tock CL, Hyman WA: Pressure wave fidelity in catheter introducers. Cathet Cardiovasc Diagn 27: 57-65, 1992.
    • (1992) Cathet Cardiovasc Diagn , vol.27 , pp. 57-65
    • Tock, C.L.1    Hyman, W.A.2
  • 5
    • 0021049792 scopus 로고
    • The frequency response of external transducer blood pressure measurement systems: A theoretical and experimental study
    • Yeomanson CW, Evans DH: The frequency response of external transducer blood pressure measurement systems: a theoretical and experimental study. Clin Phys Physiol Meas 4: 435-49, 1983.
    • (1983) Clin Phys Physiol Meas , vol.4 , pp. 435-449
    • Yeomanson, C.W.1    Evans, D.H.2
  • 7
    • 0030466025 scopus 로고    scopus 로고
    • Evaluation of transit-time and electromagnetic flow measurements in a chronically-instrumented non-human primate model
    • Koenig SC, Reister CA, Schaub J, Swope RD, Ewert DL, Fanton JW: Evaluation of transit-time and electromagnetic flow measurements in a chronically-instrumented non-human primate model. J Invest Surg 9: 455-461, 1996.
    • (1996) J Invest Surg , vol.9 , pp. 455-461
    • Koenig, S.C.1    Reister, C.A.2    Schaub, J.3    Swope, R.D.4    Ewert, D.L.5    Fanton, J.W.6
  • 8
    • 0022245850 scopus 로고
    • Velocity profiles in the wake of two prosthetic heart valves using a new cardiovascular simulator
    • Farahifar D, Cassot F, Bodard H: Velocity profiles in the wake of two prosthetic heart valves using a new cardiovascular simulator. Biomechanics 18: 789-802, 1985.
    • (1985) Biomechanics , vol.18 , pp. 789-802
    • Farahifar, D.1    Cassot, F.2    Bodard, H.3
  • 9
    • 0029310679 scopus 로고
    • Dynamic characteristics of prosthetic heart valves
    • She J, Li M, Huan L, Yu Y: Dynamic characteristics of prosthetic heart valves. Med Eng Phys 17: 273-281, 1995.
    • (1995) Med Eng Phys , vol.17 , pp. 273-281
    • She, J.1    Li, M.2    Huan, L.3    Yu, Y.4
  • 10
    • 0027141992 scopus 로고
    • In vitro strain measurement of a mechanical heart valve in a pulse simulator
    • Teoh SH, Lee KH, Nugent AH, Goh KS. In vitro strain measurement of a mechanical heart valve in a pulse simulator. ASAIO J, 39: 929-932, 1993.
    • (1993) ASAIO J , vol.39 , pp. 929-932
    • Teoh, S.H.1    Lee, K.H.2    Nugent, A.H.3    Goh, K.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.