메뉴 건너뛰기




Volumn 44, Issue 11, 1999, Pages 969-973

Accuracy of sonographically estimated fetal weight with and without oligohydramnios: A case-control study

Author keywords

Estimated fetal weight; Fetal growth retardation; Oligohydramnios; Ultrasonography

Indexed keywords

ADULT; ARTICLE; BIRTH WEIGHT; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; FEMALE; FETUS ECHOGRAPHY; FETUS WEIGHT; HUMAN; INTRAUTERINE GROWTH RETARDATION; MAJOR CLINICAL STUDY; OLIGOHYDRAMNIOS; PRIORITY JOURNAL;

EID: 0032760095     PISSN: 00247758     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (14)

References (14)
  • 1
    • 0028820024 scopus 로고
    • Antepartum surveillance in diabetic pregnancies: Predictors of fetal distress in labor
    • Kjos SL, Leung A, Henry OA, et al: Antepartum surveillance in diabetic pregnancies: Predictors of fetal distress in labor. Am J Obstet Gynecol 1995;173:1532-1539
    • (1995) Am J Obstet Gynecol , vol.173 , pp. 1532-1539
    • Kjos, S.L.1    Leung, A.2    Henry, O.A.3
  • 2
    • 0027461795 scopus 로고
    • Superiority of amniotic fluid index over amniotic fluid pocket measurement for predicting bad fetal outcome
    • Youssef AA, Abdulla SA, Sayed EH, et al: Superiority of amniotic fluid index over amniotic fluid pocket measurement for predicting bad fetal outcome. South Med J 1993;86: 426-429
    • (1993) South Med J , vol.86 , pp. 426-429
    • Youssef, A.A.1    Abdulla, S.A.2    Sayed, E.H.3
  • 3
    • 0031791894 scopus 로고    scopus 로고
    • Intrapartum amniotic fluid index: A poor predictor of abnormal fetal size
    • Hendrix NW, Chauhan SP, Magann EF, et al: Intrapartum amniotic fluid index: A poor predictor of abnormal fetal size. Obstet Gynecol 1998;92:823-827
    • (1998) Obstet Gynecol , vol.92 , pp. 823-827
    • Hendrix, N.W.1    Chauhan, S.P.2    Magann, E.F.3
  • 4
    • 0026042211 scopus 로고
    • Does amniotic fluid index affect the accuracy of estimated fetal weight in preterm premature rupture of membranes?
    • Toohey JS, Lewis DF, Harding JA, et al: Does amniotic fluid index affect the accuracy of estimated fetal weight in preterm premature rupture of membranes? Am J Obstet Gynecol 1991;165:1060-1062
    • (1991) Am J Obstet Gynecol , vol.165 , pp. 1060-1062
    • Toohey, J.S.1    Lewis, D.F.2    Harding, J.A.3
  • 5
    • 0029256537 scopus 로고
    • Effect of amniotic fluid volume on ultrasonic fetal weight estimation
    • Meyer WJ, Font GE, Gauthier DW, et al: Effect of amniotic fluid volume on ultrasonic fetal weight estimation. J Ultrasound Med 1995;14:193-197
    • (1995) J Ultrasound Med , vol.14 , pp. 193-197
    • Meyer, W.J.1    Font, G.E.2    Gauthier, D.W.3
  • 6
    • 0030466112 scopus 로고    scopus 로고
    • Accuracy of intrapartum estimates of fetal weight: Effect of oligohydramnios
    • Barnhard Y, Bar-Hava I, Divon MY: Accuracy of intrapartum estimates of fetal weight: Effect of oligohydramnios. J Reprod Med 1996;41:907-910
    • (1996) J Reprod Med , vol.41 , pp. 907-910
    • Barnhard, Y.1    Bar-Hava, I.2    Divon, M.Y.3
  • 7
    • 0023226864 scopus 로고
    • Amniotic fluid volume assessment with the four-quadrant technique at 36-42 weeks' gestation
    • Phelan JP, Smith CV, Broussard P, et al: Amniotic fluid volume assessment with the four-quadrant technique at 36-42 weeks' gestation. J Reprod Med 1987;32:540-542
    • (1987) J Reprod Med , vol.32 , pp. 540-542
    • Phelan, J.P.1    Smith, C.V.2    Broussard, P.3
  • 8
    • 0021967725 scopus 로고
    • Estimation of fetal weight with the use of head, body and femur measurements: A prospective study
    • Hadlock FP, Harrist RB, Sharman RS, et al: Estimation of fetal weight with the use of head, body and femur measurements: A prospective study. Am J Obstet Gynecol 1985;151: 333-337
    • (1985) Am J Obstet Gynecol , vol.151 , pp. 333-337
    • Hadlock, F.P.1    Harrist, R.B.2    Sharman, R.S.3
  • 9
  • 10
    • 0029852332 scopus 로고    scopus 로고
    • Intrapartum amniotic fluid index: A poor diagnostic test for adverse perinatal outcome
    • Chauhan SP, Cowan BD, Magann EF, et al: Intrapartum amniotic fluid index: A poor diagnostic test for adverse perinatal outcome. J Reprod Med 1996;41:860-866
    • (1996) J Reprod Med , vol.41 , pp. 860-866
    • Chauhan, S.P.1    Cowan, B.D.2    Magann, E.F.3
  • 11
    • 0026685248 scopus 로고
    • Prediction of the small-for-gestational-age infant: Which ultrasonic measurement is best?
    • Chang TC, Robson SC, Boys RJ, et al: Prediction of the small-for-gestational-age infant: Which ultrasonic measurement is best? Obstet Gynecol 1992;80:1030-1038
    • (1992) Obstet Gynecol , vol.80 , pp. 1030-1038
    • Chang, T.C.1    Robson, S.C.2    Boys, R.J.3
  • 12
    • 0029880114 scopus 로고    scopus 로고
    • Receiver-operator characteristic curves for the ultrasonographic prediction of small-for-gestational-age fetuses in low risk pregnancies
    • David C, Tagliavini G, Pilu G, et al: Receiver-operator characteristic curves for the ultrasonographic prediction of small-for-gestational-age fetuses in low risk pregnancies. Am J Obstet Gynecol 1996;174:1037-1042
    • (1996) Am J Obstet Gynecol , vol.174 , pp. 1037-1042
    • David, C.1    Tagliavini, G.2    Pilu, G.3
  • 13
    • 0031739160 scopus 로고    scopus 로고
    • Sonographic estimate of birth weight at 24 to 34 weeks: A multicenter study
    • Chauhan SP, Charania SF, McLaren RA, et al: Sonographic estimate of birth weight at 24 to 34 weeks: A multicenter study. Am J Obstet Gynecol 1998;179:909-916
    • (1998) Am J Obstet Gynecol , vol.179 , pp. 909-916
    • Chauhan, S.P.1    Charania, S.F.2    McLaren, R.A.3
  • 14
    • 0031972893 scopus 로고    scopus 로고
    • Limitations of clinical and sonographic estimates of birth weight: Experience with 1034 parturients
    • Chauhan SP, Hendrix NW, Magann EF, et al: Limitations of clinical and sonographic estimates of birth weight: Experience with 1034 parturients. Obstet Gynecol 1998;91: 72-77
    • (1998) Obstet Gynecol , vol.91 , pp. 72-77
    • Chauhan, S.P.1    Hendrix, N.W.2    Magann, E.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.