-
1
-
-
0021962310
-
Acute and long-term atrial and ventricular stimulation thresholds with a steroid eluting electrode
-
1. Kruse IM, Terpstra B. Acute and long-term atrial and ventricular stimulation thresholds with a steroid eluting electrode. PACE 1985; 8:48-49.
-
(1985)
PACE
, vol.8
, pp. 48-49
-
-
Kruse, I.M.1
Terpstra, B.2
-
2
-
-
0344650511
-
The porous titanium steroid eluting electrode: A double blind study assessing the stimulation threshold effects of steroid
-
2. Mond H, Stokes K, Helland J, et al. The porous titanium steroid eluting electrode: A double blind study assessing the stimulation threshold effects of steroid. PACE 1988; 11:214-219.
-
(1988)
PACE
, vol.11
, pp. 214-219
-
-
Mond, H.1
Stokes, K.2
Helland, J.3
-
3
-
-
0024209303
-
Clinical experience with steroid-eluting unipolar electrodes
-
3. Pirzada FA, Moschitto LJ, DiOrio D. Clinical experience with steroid-eluting unipolar electrodes. PACE 1988; 11:1939-44.
-
(1988)
PACE
, vol.11
, pp. 1939-1944
-
-
Pirzada, F.A.1
Moschitto, L.J.2
Diorio, D.3
-
4
-
-
0025649796
-
Steroid tipped leads versus porous platinum permanent pacemaker leads: A controlled study
-
4. Wish M, Swartz J, Cohen A, et al. Steroid tipped leads versus porous platinum permanent pacemaker leads: A controlled study. PACE 1990; 13:1887-1990.
-
(1990)
PACE
, vol.13
, pp. 1887-1990
-
-
Wish, M.1
Swartz, J.2
Cohen, A.3
-
5
-
-
0025045994
-
Stimulation characteristics of steroid eluting electrode compared with three conventional electrodes
-
5. Klein HH, Steinberger J, Knake W. Stimulation characteristics of steroid eluting electrode compared with three conventional electrodes. PACE 1990; 13:134-137.
-
(1990)
PACE
, vol.13
, pp. 134-137
-
-
Klein, H.H.1
Steinberger, J.2
Knake, W.3
-
6
-
-
0026315543
-
2) on steroid eluting leads
-
2) on steroid eluting leads. PACE 1991; 14:2098-2104.
-
(1991)
PACE
, vol.14
, pp. 2098-2104
-
-
Schuchert, A.1
Kuck, K.H.2
-
7
-
-
0026529384
-
The safey and efficacy of chronic ventricular pacing at 1.6 volts using a steroid eluting lead
-
7. Stamato NJ, O'Toole MF, Fetter JG, et al. The safey and efficacy of chronic ventricular pacing at 1.6 volts using a steroid eluting lead. PACE 1992; 15:248-251.
-
(1992)
PACE
, vol.15
, pp. 248-251
-
-
Stamato, N.J.1
O'Toole, M.F.2
Fetter, J.G.3
-
8
-
-
0027315354
-
Do steroid electrodes really have better performance than other state of the art designs?
-
8. Santini M, De Seta F. Do steroid electrodes really have better performance than other state of the art designs? PACE 1993; 16:722-728.
-
(1993)
PACE
, vol.16
, pp. 722-728
-
-
Santini, M.1
De Seta, F.2
-
9
-
-
0027215372
-
A randomized comparison of bipolar steroid-eluting electrode and a bipolar microporous platinum electrode: Implications for long-term programming
-
9. Gillis AM, Rothschild JM, Hillier K, et al. A randomized comparison of bipolar steroid-eluting electrode and a bipolar microporous platinum electrode: Implications for long-term programming. PACE 1993; 16:964-970.
-
(1993)
PACE
, vol.16
, pp. 964-970
-
-
Gillis, A.M.1
Rothschild, J.M.2
Hillier, K.3
-
10
-
-
0025609846
-
A new efficient nanotip lead
-
10. Stokes KB, Bird T. A new efficient nanotip lead. PACE 1990; 13:1901-1905.
-
(1990)
PACE
, vol.13
, pp. 1901-1905
-
-
Stokes, K.B.1
Bird, T.2
-
11
-
-
0000077660
-
2) on unipolar steroid lead (Capsure Z): 6 month results
-
2) on unipolar steroid lead (Capsure Z): 6 month results, (abstract) PACE 1995; 18(Pt II): 1183.
-
(1995)
PACE
, vol.18
, Issue.PT II
, pp. 1183
-
-
Moracchini, P.V.1
Bernasconi, M.2
Cornacchio, D.3
-
12
-
-
0009542123
-
One year follow-up of high impedance, low threshold leads
-
12. Breivik K, Danilovic D, Ohm OJ, et al. One year follow-up of high impedance, low threshold leads, (abstract) PACE 1995; 18:1823.
-
(1995)
PACE
, vol.18
, pp. 1823
-
-
Breivik, K.1
Danilovic, D.2
Ohm, O.J.3
-
13
-
-
9044243404
-
2 high impedance, steroid-eluting pacing electrodes
-
2 high impedance, steroid-eluting pacing electrodes. PACE 1996; 19:188-196.
-
(1996)
PACE
, vol.19
, pp. 188-196
-
-
Fogel, R.1
Pirzada, F.2
Casavant, D.3
-
14
-
-
0030431990
-
High impedance and low energy stimulation with bipolar ultra-small electrode steroid eluting lead (CapSure Z)
-
14. Puglisi A, Ricci R, Neja CP, et al. High impedance and low energy stimulation with bipolar ultra-small electrode steroid eluting lead (CapSure Z). Eur J Cardiac Pacing Electrophysiol 1996; 6: 132-136.
-
(1996)
Eur J Cardiac Pacing Electrophysiol
, vol.6
, pp. 132-136
-
-
Puglisi, A.1
Ricci, R.2
Neja, C.P.3
-
15
-
-
0030924484
-
Initial experience with a high-impedance tined endocardial pacemaker lead: Evidence for increased lead failure
-
15. Joglar JA, Welch P, Wilkinson WE, et al. Initial experience with a high-impedance tined endocardial pacemaker lead: Evidence for increased lead failure. Am Heart J 1997; 134:161-64.
-
(1997)
Am Heart J
, vol.134
, pp. 161-164
-
-
Joglar, J.A.1
Welch, P.2
Wilkinson, W.E.3
-
16
-
-
0009513588
-
Why thresholds change and the effects of steroid elution
-
16. Stokes K, Anderson J. Why thresholds change and the effects of steroid elution. PACE 1991; 4:731.
-
(1991)
PACE
, vol.4
, pp. 731
-
-
Stokes, K.1
Anderson, J.2
-
17
-
-
0009483927
-
Prednisone in the management of exit block
-
C. Meere (ed.): Montreal, Pacesymposium, chapter 18-3
-
17. Beanlands DS, Akyurelkli Y, Keon WJ. Prednisone in the management of exit block. In C. Meere (ed.): Proceedings of the VI World Symposium on Cardiac Pacing. Montreal, Pacesymposium, 1979, chapter 18-3.
-
(1979)
Proceedings of the VI World Symposium on Cardiac Pacing
-
-
Beanlands, D.S.1
Akyurelkli, Y.2
Keon, W.J.3
-
18
-
-
0024383436
-
Pacing failure due to markedly increased stimulation threshold 2 years after implantation: Successful management with oral prednisone: A case report
-
18. Nagamoto Y, Ogawa T, Haruhito K. Pacing failure due to markedly increased stimulation threshold 2 years after implantation: Successful management with oral prednisone: A case report. PACE 1989; 12:1034-1037.
-
(1989)
PACE
, vol.12
, pp. 1034-1037
-
-
Nagamoto, Y.1
Ogawa, T.2
Haruhito, K.3
-
19
-
-
0029835108
-
The steroid eluting electrode: A 10-year experience
-
19. Mond HG, Stokes KB. The steroid eluting electrode: A 10-year experience. PACE 1996; 19: 1016-1020.
-
(1996)
PACE
, vol.19
, pp. 1016-1020
-
-
Mond, H.G.1
Stokes, K.B.2
|