메뉴 건너뛰기




Volumn 54, Issue 12, 1999, Pages 1155-1160

Minimum alveolar sevoflurane concentrations required for insertion of the cuffed oropharyngeal airway and the laryngeal mask airway: A comparative study

Author keywords

Anaesthetics, volatile; sevoflurane; Equipment; laryngeal mask airway, cuffed oropharyngeal airway

Indexed keywords

INHALATION ANESTHETIC AGENT; SEVOFLURANE;

EID: 0032757613     PISSN: 00032409     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1365-2044.1999.01078.x     Document Type: Article
Times cited : (19)

References (16)
  • 1
    • 0031948534 scopus 로고    scopus 로고
    • A randomized controlled trial comparing the cuffed oropharyngeal airway and the laryngeal mask airway in spontaneously breathing anesthetized adults
    • Greenberg RS, Brimacombe J, Berry A, Gouze V, Piantadosi S, Dake EM. A randomized controlled trial comparing the cuffed oropharyngeal airway and the laryngeal mask airway in spontaneously breathing anesthetized adults. Anesthesiology 1998; 88: 970-7.
    • (1998) Anesthesiology , vol.88 , pp. 970-977
    • Greenberg, R.S.1    Brimacombe, J.2    Berry, A.3    Gouze, V.4    Piantadosi, S.5    Dake, E.M.6
  • 2
    • 0031807759 scopus 로고    scopus 로고
    • A comparison of the laryngeal mask airway and cuffed oropharyngeal airway in anesthetized adult patients
    • Brimacombe JR, Brimacombe JC, Berry AM, et al. A comparison of the laryngeal mask airway and cuffed oropharyngeal airway in anesthetized adult patients. Anesthesia and Analgesia 1998; 87: 147-52.
    • (1998) Anesthesia and Analgesia , vol.87 , pp. 147-152
    • Brimacombe, J.R.1    Brimacombe, J.C.2    Berry, A.M.3
  • 3
    • 0031807125 scopus 로고    scopus 로고
    • The placement of the cuffed oropharyngeal airway with sevoflurane in adults: A comparison with the laryngeal mask airway
    • Nakata Y, Goto T, Saito H, Ichinose F, Uezono S, Monta S. The placement of the cuffed oropharyngeal airway with sevoflurane in adults: a comparison with the laryngeal mask airway. Anesthesia and Analgesia 1998; 87: 143-6.
    • (1998) Anesthesia and Analgesia , vol.87 , pp. 143-146
    • Nakata, Y.1    Goto, T.2    Saito, H.3    Ichinose, F.4    Uezono, S.5    Monta, S.6
  • 4
    • 0028240990 scopus 로고
    • The haemodynamic response to the insertion of the laryngeal mask airway: A comparison with laryngoscopy and tracheal intubation
    • Wood ML, Forrest ET. The haemodynamic response to the insertion of the laryngeal mask airway: a comparison with laryngoscopy and tracheal intubation. Acta Anaesthesiologica Scandinavica 1994; 38: 510-13.
    • (1994) Acta Anaesthesiologica Scandinavica , vol.38 , pp. 510-513
    • Wood, M.L.1    Forrest, E.T.2
  • 5
    • 0026581912 scopus 로고
    • Cardiovascular responses to insertion ot the laryngeal mask
    • Wilson IG, Fell D, Robinson SL, Smith G. Cardiovascular responses to insertion ot the laryngeal mask. Anaesthesia 1992; 47: 300-2.
    • (1992) Anaesthesia , vol.47 , pp. 300-302
    • Wilson, I.G.1    Fell, D.2    Robinson, S.L.3    Smith, G.4
  • 6
    • 0027499111 scopus 로고
    • Minimum alveolar concentration of sevoflurane in elderly patients
    • Nakajima R, Nakajima Y, Ikeda K. Minimum alveolar concentration of sevoflurane in elderly patients. British Journal of Anaesthesia 1993; 70: 273-5.
    • (1993) British Journal of Anaesthesia , vol.70 , pp. 273-275
    • Nakajima, R.1    Nakajima, Y.2    Ikeda, K.3
  • 8
    • 0002345783 scopus 로고
    • Quantal response to variable experimentation: The up-and-down method
    • McArthur JW, Colton T, eds. MA: MIT Press
    • Dixon WJ. Quantal response to variable experimentation: the up-and-down method. In: McArthur JW, Colton T, eds. Statistics in Endocrinology. Cambridge, MA: MIT Press, 1967; 251-64.
    • (1967) Statistics in Endocrinology. Cambridge , pp. 251-264
    • Dixon, W.J.1
  • 10
    • 0029925799 scopus 로고    scopus 로고
    • Analysis of 1500 laryngeal mask uses by one anaesthetist in adults undergoing routine anaesthesia
    • Brimacombe J. Analysis of 1500 laryngeal mask uses by one anaesthetist in adults undergoing routine anaesthesia. Anaesthesia 1996; 51: 76-80.
    • (1996) Anaesthesia , vol.51 , pp. 76-80
    • Brimacombe, J.1
  • 11
    • 0029919596 scopus 로고    scopus 로고
    • Laryngeal mask airway in pediatric practice: A prospective study of skill acquisition by anesthesia residents
    • Lopez-Gil M, Brimacombe J, Cebrian J, Arranz J. Laryngeal mask airway in pediatric practice: a prospective study of skill acquisition by anesthesia residents. Anesthesiology 1996; 84: 807-11.
    • (1996) Anesthesiology , vol.84 , pp. 807-811
    • Lopez-Gil, M.1    Brimacombe, J.2    Cebrian, J.3    Arranz, J.4
  • 12
    • 0027517919 scopus 로고
    • Minimum alveolar concentration of desflurane in patients older than 65 yr
    • Gold MI, Abello D, Herrington C. Minimum alveolar concentration of desflurane in patients older than 65 yr. Anesthesiology 1993; 79: 710-14.
    • (1993) Anesthesiology , vol.79 , pp. 710-714
    • Gold, M.I.1    Abello, D.2    Herrington, C.3
  • 13
    • 0027465107 scopus 로고
    • Influence of age on awakening concentrations of sevoflurane and isoflurane
    • Katoh T, Suguro Y, Ikeda T, Kazama T, Ikeda K. Influence of age on awakening concentrations of sevoflurane and isoflurane. Anesthesia and Analgesia 1993; 76: 348-52.
    • (1993) Anesthesia and Analgesia , vol.76 , pp. 348-352
    • Katoh, T.1    Suguro, Y.2    Ikeda, T.3    Kazama, T.4    Ikeda, K.5
  • 14
    • 0028110373 scopus 로고
    • End-tidal sevoflurane concentrations for laryngeal mask airway insertion and for tracheal intubation in children
    • Taguchi M, Watanabe S, Asakura N, Inomata S. End-tidal sevoflurane concentrations for laryngeal mask airway insertion and for tracheal intubation in children. Anesthesiology 1994; 81: 628-31.
    • (1994) Anesthesiology , vol.81 , pp. 628-631
    • Taguchi, M.1    Watanabe, S.2    Asakura, N.3    Inomata, S.4
  • 16
    • 0028074918 scopus 로고
    • Sensitivity of upper airway reflexes in cigarette smokers: Effect of abstinence
    • Erskine RJ, Murphy PJ, Langton JA. Sensitivity of upper airway reflexes in cigarette smokers: effect of abstinence. British Journal of Anaesthesia 1994; 73: 298-302.
    • (1994) British Journal of Anaesthesia , vol.73 , pp. 298-302
    • Erskine, R.J.1    Murphy, P.J.2    Langton, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.