메뉴 건너뛰기




Volumn 11, Issue 2, 1999, Pages 59-62

Optic disc size, an important consideration in the glaucoma evaluation

Author keywords

Cup to disc ratio; Glaucoma; Optic disc

Indexed keywords

BIOMICROSCOPY; CONTACT LENS; EYE PHOTOGRAPHY; GLAUCOMA; HUMAN; MEASUREMENT; OPTIC DISK; OPTIC DISK CUP; OPTIC NERVE; REVIEW; SCANNING LASER OPHTHALMOSCOPY;

EID: 0032754853     PISSN: 09534431     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0953-4431(99)00012-0     Document Type: Article
Times cited : (47)

References (21)
  • 1
    • 0018838445 scopus 로고
    • The mode of progressive disc cupping in ocular hypertension and glaucoma
    • Pederson J.E., Anderson D.R. The mode of progressive disc cupping in ocular hypertension and glaucoma. Arch Ophthalmol. 98:1980;490-495.
    • (1980) Arch Ophthalmol , vol.98 , pp. 490-495
    • Pederson, J.E.1    Anderson, D.R.2
  • 2
    • 0020042426 scopus 로고
    • Optic nerve damage in human glaucoma. III. Quantitative correlation of nerve fiber loss and visual field defect in glaucoma, ischemic neuropathy, papilledema, and toxic neuropathy
    • Quigley H.A., Addicks E.M., Green W.R. Optic nerve damage in human glaucoma. III. Quantitative correlation of nerve fiber loss and visual field defect in glaucoma, ischemic neuropathy, papilledema, and toxic neuropathy. Arch Ophthalmol. 100:1982;135-146.
    • (1982) Arch Ophthalmol , vol.100 , pp. 135-146
    • Quigley, H.A.1    Addicks, E.M.2    Green, W.R.3
  • 3
    • 0018416802 scopus 로고
    • Optic disc parameters and onset of glaucomatous field loss 1. Methods and progressive changes in disc morphology
    • Sommer A., Polack I., Maumenee A.E. Optic disc parameters and onset of glaucomatous field loss 1. Methods and progressive changes in disc morphology. Arch Ophthalmol. 97:1979;1444-1448.
    • (1979) Arch Ophthalmol , vol.97 , pp. 1444-1448
    • Sommer, A.1    Polack, I.2    Maumenee, A.E.3
  • 4
    • 0027955905 scopus 로고
    • Race-, gender-, and refractive error-related differences in the normal optic disc
    • Varma R., Tielsch J.M., Quigley H.A. et al. Race-, gender-, and refractive error-related differences in the normal optic disc. Arch Ophthalmol. 112:1994;1068-1076.
    • (1994) Arch Ophthalmol , vol.112 , pp. 1068-1076
    • Varma, R.1    Tielsch, J.M.2    Quigley, H.A.3
  • 7
    • 0017193257 scopus 로고
    • The variation and covariation or cup and disc diameters
    • Bengtsson B. The variation and covariation or cup and disc diameters. Acta Ophthalmol (Copenh). 54:1976;804-818.
    • (1976) Acta Ophthalmol (Copenh) , vol.54 , pp. 804-818
    • Bengtsson, B.1
  • 9
    • 0023503113 scopus 로고
    • Optic disc rim area is related to disc size in normal subjects
    • Caprioli J., Miller J.M. Optic disc rim area is related to disc size in normal subjects. Arch Ophthalmol. 105:1987;1683-1685.
    • (1987) Arch Ophthalmol , vol.105 , pp. 1683-1685
    • Caprioli, J.1    Miller, J.M.2
  • 11
    • 0022560259 scopus 로고
    • The correlation between cup-disk ration, neuroretinal rim area, and the optic disc area measured by the video ophthalmograph (Rodenstock Analyzer) and clinical measurement
    • Mikelberg F.S., Douglas G.R., Schuler M., Airaksinen P.J., Wijsman K., Mawson D. The correlation between cup-disk ration, neuroretinal rim area, and the optic disc area measured by the video ophthalmograph (Rodenstock Analyzer) and clinical measurement. Am J Ophthalmol. 101:1986;7-12.
    • (1986) Am J Ophthalmol , vol.101 , pp. 7-12
    • Mikelberg, F.S.1    Douglas, G.R.2    Schuler, M.3    Airaksinen, P.J.4    Wijsman, K.5    Mawson, D.6
  • 12
    • 0014104902 scopus 로고
    • Genetic determination of cup/disk ratio of the optic nerve
    • Armaly M.F. Genetic determination of cup/disk ratio of the optic nerve. Arch Ophthalmol. 78:1967;35-43.
    • (1967) Arch Ophthalmol , vol.78 , pp. 35-43
    • Armaly, M.F.1
  • 13
    • 0023710404 scopus 로고
    • Optic disc, cup and neuroretinal rim size, configuration and correlation in normal eyes
    • Jonas J.B., Gusek G.C., Naumann G.O.H. Optic disc, cup and neuroretinal rim size, configuration and correlation in normal eyes. Invest Ophthalmol Vis Sci. 29:1988;1151.
    • (1988) Invest Ophthalmol Vis Sci , vol.29 , pp. 1151
    • Jonas, J.B.1    Gusek, G.C.2    Naumann, G.O.H.3
  • 14
    • 0027404260 scopus 로고
    • Confocal laser scanning ophthalmoscope-reproducibility of optic nerve head topographic measurements with the confocal laser scanning ophthalmoscope
    • Cioffi G.A., Robin A.L., Eastman R.D., Perell H.F., Sarfarazi F.A., Kelman S.E. Confocal laser scanning ophthalmoscope-reproducibility of optic nerve head topographic measurements with the confocal laser scanning ophthalmoscope. Ophthalmology. 100:1993;57-62.
    • (1993) Ophthalmology , vol.100 , pp. 57-62
    • Cioffi, G.A.1    Robin, A.L.2    Eastman, R.D.3    Perell, H.F.4    Sarfarazi, F.A.5    Kelman, S.E.6
  • 15
    • 0021255226 scopus 로고
    • Neuroretinal rim area in suspected glaucoma and early chronic open-angle glaucoma
    • Balazsi A.G., Drance S.M., Schulzer M., Douglas G.R. Neuroretinal rim area in suspected glaucoma and early chronic open-angle glaucoma. Arch Ophthalmol. 102:1984;1011-1014.
    • (1984) Arch Ophthalmol , vol.102 , pp. 1011-1014
    • Balazsi, A.G.1    Drance, S.M.2    Schulzer, M.3    Douglas, G.R.4
  • 16
    • 0027971321 scopus 로고
    • Optic disc measurement with the Zeiss four mirror contact lens
    • Spencer A.F., Vernon S.A. Optic disc measurement with the Zeiss four mirror contact lens. Br J Ophthalmol. 78:1994;775-780.
    • (1994) Br J Ophthalmol , vol.78 , pp. 775-780
    • Spencer, A.F.1    Vernon, S.A.2
  • 17
    • 0030063096 scopus 로고    scopus 로고
    • Repeatability and reproducibility of optic disc measurement with the Zeiss 4-mirror contact lens
    • Spencer A.F., Vernon S.A. Repeatability and reproducibility of optic disc measurement with the Zeiss 4-mirror contact lens. Ophthalmology. 103:1996;163-167.
    • (1996) Ophthalmology , vol.103 , pp. 163-167
    • Spencer, A.F.1    Vernon, S.A.2
  • 18
    • 0029093723 scopus 로고
    • Ophthalmoscopic measurement of the optic disc
    • Jonas J.B., Papastathopoulos K. Ophthalmoscopic measurement of the optic disc. Ophthalmology. 102:1995;1102-1106.
    • (1995) Ophthalmology , vol.102 , pp. 1102-1106
    • Jonas, J.B.1    Papastathopoulos, K.2
  • 19
    • 0028245435 scopus 로고
    • Estimation of the optic disc size using indirect biomicroscopy
    • Ruben S. Estimation of the optic disc size using indirect biomicroscopy. Br J Ophthalmol. 78:1994;363-364.
    • (1994) Br J Ophthalmol , vol.78 , pp. 363-364
    • Ruben, S.1
  • 20
    • 0029838516 scopus 로고    scopus 로고
    • A simple clinical method to measure the optic disc size in glaucoma
    • Lim C.S., O'Brien C., Bolton N.M. A simple clinical method to measure the optic disc size in glaucoma. J Glaucoma. 5:1996;241-245.
    • (1996) J Glaucoma , vol.5 , pp. 241-245
    • Lim, C.S.1    O'Brien, C.2    Bolton, N.M.3
  • 21
    • 0027474018 scopus 로고
    • Optic disc diameter influences the ability to detect glaucomatous disc damage
    • Heiji A., Molder H. Optic disc diameter influences the ability to detect glaucomatous disc damage. Acta Ophthalmol. 71:1993;122-129.
    • (1993) Acta Ophthalmol , vol.71 , pp. 122-129
    • Heiji, A.1    Molder, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.