메뉴 건너뛰기




Volumn 33, Issue 6, 1999, Pages 663-669

Comparison of Preoperative and Postoperative Duplex Ultrasound Evaluation of the Contralateral Carotid Artery

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CAROTID ARTERY OBSTRUCTION; CAROTID ENDARTERECTOMY; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; DIAGNOSTIC VALUE; DISEASE SEVERITY; ECHOGRAPHY; HUMAN; MAJOR CLINICAL STUDY; PREOPERATIVE EVALUATION;

EID: 0032753473     PISSN: 15385744     EISSN: None     Source Type: Journal    
DOI: 10.1177/153857449903300613     Document Type: Article
Times cited : (3)

References (13)
  • 1
    • 0029783676 scopus 로고    scopus 로고
    • Evaluation of carotid artery stenosis: Is duplex ultrasonography sufficient?
    • Muto PM, Welch HJ, Mackey WC, et al: Evaluation of carotid artery stenosis: Is duplex ultrasonography sufficient? J Vasc Surg. 24:17-24, 1996.
    • (1996) J Vasc Surg , vol.24 , pp. 17-24
    • Muto, P.M.1    Welch, H.J.2    Mackey, W.C.3
  • 2
    • 0026524365 scopus 로고
    • Comparison of magnetic resonance angiography, conventional angiography, and duplex scanning
    • Riles TS, Eidelman EM, Litt AW, et al: Comparison of magnetic resonance angiography, conventional angiography, and duplex scanning. Stroke. 23:341-346, 1992.
    • (1992) Stroke , vol.23 , pp. 341-346
    • Riles, T.S.1    Eidelman, E.M.2    Litt, A.W.3
  • 3
    • 0026704528 scopus 로고
    • Assessment of carotid artery stenosis by MR angiography: Comparison with x-ray angiography and color-coded Doppler ultrasound
    • Anderson CM, Saloner D, Lee RE, et al: Assessment of carotid artery stenosis by MR angiography: Comparison with x-ray angiography and color-coded Doppler ultrasound. Am J Neuroradiol. 13:989-1003, 1992.
    • (1992) Am J Neuroradiol , vol.13 , pp. 989-1003
    • Anderson, C.M.1    Saloner, D.2    Lee, R.E.3
  • 4
    • 0025285879 scopus 로고
    • Contralateral internal carotid artery stenosis or occlusion: pitfall of correct ipsilateral classification a study performed with color flow
    • Spadone DP, Barkmeier LD, Hodgson KJ, et al: Contralateral internal carotid artery stenosis or occlusion: pitfall of correct ipsilateral classification a study performed with color flow. J Vasc Surg. 11:642-649, 1990.
    • (1990) J Vasc Surg , vol.11 , pp. 642-649
    • Spadone, D.P.1    Barkmeier, L.D.2    Hodgson, K.J.3
  • 5
    • 0025041572 scopus 로고
    • Duplex Doppler sonography of the carotid artery: False-positive results in an artery contralateral to an artery with marked stenosis
    • Beckett WW Jr, Davis PC, Hoffman JC Jr: Duplex Doppler sonography of the carotid artery: False-positive results in an artery contralateral to an artery with marked stenosis. Am J Neuroradiol. 11:1049-1053, 1990.
    • (1990) Am J Neuroradiol , vol.11 , pp. 1049-1053
    • Beckett, W.W.1    Davis, P.C.2    Hoffman, J.C.3
  • 6
    • 0030218098 scopus 로고    scopus 로고
    • Carotid duplex overestimation of stenosis due to severe contralateral disease
    • Busuttil SJ, Franklin DP, Youkey JR, et al: Carotid duplex overestimation of stenosis due to severe contralateral disease. Am J Surg. 172:144-148, 1996.
    • (1996) Am J Surg , vol.172 , pp. 144-148
    • Busuttil, S.J.1    Franklin, D.P.2    Youkey, J.R.3
  • 7
    • 0011785368 scopus 로고
    • The effect of contralateral disease on carotid duplex accuracy
    • Patterson RB, Sullivan DC, Bozman RE: The effect of contralateral disease on carotid duplex accuracy. J Vasc Tech. 16:238-240, 1992.
    • (1992) J Vasc Tech , vol.16 , pp. 238-240
    • Patterson, R.B.1    Sullivan, D.C.2    Bozman, R.E.3
  • 8
    • 0002062740 scopus 로고
    • Noninvasive dynamic and real-time assessment of extracranial cerebrovasculature
    • ed. by Wood JH. New York: McGraw Hill, pp.
    • Zierler RE, Strandness DE Jr: Noninvasive dynamic and real-time assessment of extracranial cerebrovasculature. In: Cerebral Blood Flow: Physiologic and Clinical Aspects, ed. by Wood JH. New York: McGraw Hill, 1987, pp 311-323.
    • (1987) Cerebral Blood Flow: Physiologic and Clinical Aspects , pp. 311-323
    • Zierler, R.E.1    Strandness, D.E.2
  • 9
    • 0019936598 scopus 로고
    • Problems of carotid Doppler scanning which can be overcome by using frequency analysis
    • Jchnston KW, Brown PM, Kassam M: Problems of carotid Doppler scanning which can be overcome by using frequency analysis. Stroke. 13:660-666, 1982.
    • (1982) Stroke , vol.13 , pp. 660-666
    • Jchnston, K.W.1    Brown, P.M.2    Kassam, M.3
  • 10
    • 0023839175 scopus 로고
    • The effect of contralateral disease on carotid Doppler frequency
    • Hayes AC, Johnston KW, Baker WH, et al: The effect of contralateral disease on carotid Doppler frequency. Surgery. 103:19-23, 1988.
    • (1988) Surgery , vol.103 , pp. 19-23
    • Hayes, A.C.1    Johnston, K.W.2    Baker, W.H.3
  • 11
    • 0029558236 scopus 로고
    • Effect of contralateral severe stenosis or carotid occlusion on duplex criteria of ipsilateral stenoses: Comparative study of various duplex parameters
    • AbuRahma AF, Richmond BK, Robinson PA, et al: Effect of contralateral severe stenosis or carotid occlusion on duplex criteria of ipsilateral stenoses: Comparative study of various duplex parameters. J Vasc Surg. 22:751-762, 1995.
    • (1995) J Vasc Surg , vol.22 , pp. 751-762
    • AbuRahma, A.F.1    Richmond, B.K.2    Robinson, P.A.3
  • 12
    • 0021934270 scopus 로고
    • Influence of contralateral obstructions on Doppler frequency spectral analysis of ipsilateral stenoses of the carotid arteries
    • Fischer M, Alexander K: Influence of contralateral obstructions on Doppler frequency spectral analysis of ipsilateral stenoses of the carotid arteries. Stroke. 16:846-848, 1985.
    • (1985) Stroke , vol.16 , pp. 846-848
    • Fischer, M.1    Alexander, K.2
  • 13
    • 0031880793 scopus 로고    scopus 로고
    • Long-term hemodynamic effects of carotid endarterectomy
    • Kluytmans M, van der Grond J, Eikelboom BC, et al: Long-term hemodynamic effects of carotid endarterectomy. Stroke. 29:1567-1572, 1998.
    • (1998) Stroke , vol.29 , pp. 1567-1572
    • Kluytmans, M.1    van der Grond, J.2    Eikelboom, B.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.