메뉴 건너뛰기




Volumn 116, Issue 4, 1999, Pages 1025-1028

Reengineering respiratory support following extubation: Avoidance of critical care unit costs

Author keywords

Cost effectiveness; Extubation; Hypoxemia; ICU; Noninvasive positive pressure ventilation; Oxygen; Reintubation; Surgery; Trauma

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; ASSISTED VENTILATION; EXTUBATION; HOSPITAL COST; HUMAN; INTENSIVE CARE; INTENSIVE CARE UNIT; MAJOR CLINICAL STUDY; OXYGEN THERAPY; PRIORITY JOURNAL; UNIVERSITY HOSPITAL;

EID: 0032744775     PISSN: 00123692     EISSN: None     Source Type: Journal    
DOI: 10.1378/chest.116.4.1025     Document Type: Article
Times cited : (18)

References (23)
  • 1
    • 0029399436 scopus 로고
    • Against routine postoperative oxygen administration in the PACU
    • 1 DiBenedetto RJ, Gravenstein N. Against routine postoperative oxygen administration in the PACU. J Clin Monit 1995; 11:408-410
    • (1995) J Clin Monit , vol.11 , pp. 408-410
    • DiBenedetto, R.J.1    Gravenstein, N.2
  • 2
    • 0028010094 scopus 로고
    • Pulse oximetry monitoring can change routine oxygen supplementation practices in the postanesthesia care unit
    • 2 DiBenedetto RJ, Graves SA, Gravenstein N, et al. Pulse oximetry monitoring can change routine oxygen supplementation practices in the postanesthesia care unit. Anesth Analg 1994; 78:365-368
    • (1994) Anesth Analg , vol.78 , pp. 365-368
    • DiBenedetto, R.J.1    Graves, S.A.2    Gravenstein, N.3
  • 3
    • 0028017697 scopus 로고
    • The cost of oxygen therapy in the postanesthesia care unit
    • 3 Rosenberg MK. The cost of oxygen therapy in the postanesthesia care unit [letter]. Anesth Analg 1994; 79:816
    • (1994) Anesth Analg , vol.79 , pp. 816
    • Rosenberg, M.K.1
  • 6
    • 0027462423 scopus 로고
    • Effect on lung volumes of oxygen concentration when breathing is restricted
    • 6 Baker AV, McGinn A, Joyce C. Effect on lung volumes of oxygen concentration when breathing is restricted. Br J Anesth 1993; 70:259-266
    • (1993) Br J Anesth , vol.70 , pp. 259-266
    • Baker, A.V.1    McGinn, A.2    Joyce, C.3
  • 8
    • 0029843066 scopus 로고    scopus 로고
    • Re-engineering ventilatory support to decrease days and improve resource utilization
    • 8 Kirton OC, DeHaven B, Hudson-Civetta J, et al. Re-engineering ventilatory support to decrease days and improve resource utilization. Ann Surg 1996; 224:396-404
    • (1996) Ann Surg , vol.224 , pp. 396-404
    • Kirton, O.C.1    DeHaven, B.2    Hudson-Civetta, J.3
  • 9
    • 0028234023 scopus 로고
    • Prevention of hypoxemia: The simple, logical, but incorrect solution
    • 9 Downs JB. Prevention of hypoxemia: the simple, logical, but incorrect solution [editorial]. J Clin Anesth 1994; 6:180-181
    • (1994) J Clin Anesth , vol.6 , pp. 180-181
    • Downs, J.B.1
  • 10
    • 85030361988 scopus 로고
    • Measuring arterial hemoglobin (SaO2) after anesthesia: Time for a new postanesthesia recovery score
    • 10 Kamal GD, Hassell RH, Pylern SM, et al. Measuring arterial hemoglobin (SaO2) after anesthesia: time for a new postanesthesia recovery score. Anesth and Analg 1992; 74:S156
    • (1992) Anesth and Analg , vol.74
    • Kamal, G.D.1    Hassell, R.H.2    Pylern, S.M.3
  • 11
    • 0027305398 scopus 로고
    • Hypoxemic episodes of patients in a postanesthesia care unit
    • 11 Garfield BR, Grabeal JM. Hypoxemic episodes of patients in a postanesthesia care unit. Chest 1993; 104:899-903
    • (1993) Chest , vol.104 , pp. 899-903
    • Garfield, B.R.1    Grabeal, J.M.2
  • 12
    • 0028337587 scopus 로고
    • Postanesthesia monitoring revisited: Frequency of true and false alarms from different monitoring devices
    • 12 Wiklund L, Hok B, Stahl K, et al. Postanesthesia monitoring revisited: frequency of true and false alarms from different monitoring devices. J Clin Anesth 1994; 6:182-188
    • (1994) J Clin Anesth , vol.6 , pp. 182-188
    • Wiklund, L.1    Hok, B.2    Stahl, K.3
  • 13
    • 0027310579 scopus 로고
    • Supplemental oxygen does not reduce myocardial ischemia in premedicated patients with critical coronary artery disease
    • 13 Kavanagh BP, Cheng DCH, Sandler AN, et al. Supplemental oxygen does not reduce myocardial ischemia in premedicated patients with critical coronary artery disease. Anesth Analg 1993; 76:950-956
    • (1993) Anesth Analg , vol.76 , pp. 950-956
    • Kavanagh, B.P.1    Cheng, D.C.H.2    Sandler, A.N.3
  • 14
    • 0029837057 scopus 로고    scopus 로고
    • Non-invasive positive-pressure ventilation in patients with acute respiratory failure
    • 14 Meduri GU. Non-invasive positive-pressure ventilation in patients with acute respiratory failure. Clin Chest Med 1996; 17:513-533
    • (1996) Clin Chest Med , vol.17 , pp. 513-533
    • Meduri, G.U.1
  • 16
    • 0022004915 scopus 로고
    • Mean airway pressure vs positive end expiratory pressure during mechanical ventilation
    • 16 Pesenti A, Marcolin R, Paulo P, et al. Mean airway pressure vs positive end expiratory pressure during mechanical ventilation. Crit Care Med 1985; 13:34-37
    • (1985) Crit Care Med , vol.13 , pp. 34-37
    • Pesenti, A.1    Marcolin, R.2    Paulo, P.3
  • 17
    • 0030051475 scopus 로고    scopus 로고
    • Noninvasive positive pressure ventilation via face mask: First line intervention in patients with acute hypercapnic and hypoxemic respiratory failure
    • 17 Meduri GU, Turner RE, Abou-Shala N, et al. Noninvasive positive pressure ventilation via face mask: first line intervention in patients with acute hypercapnic and hypoxemic respiratory failure. Chest 1996; 109:179-193.
    • (1996) Chest , vol.109 , pp. 179-193
    • Meduri, G.U.1    Turner, R.E.2    Abou-Shala, N.3
  • 18
    • 0026332579 scopus 로고
    • Noninvasive face mask ventilation in patients with acute hypercapnic respiratory failure
    • 18 Meduri GU, Abou-Shala N, Fox RC, et al. Noninvasive face mask ventilation in patients with acute hypercapnic respiratory failure. Chest 1981; 100:445-454
    • (1981) Chest , vol.100 , pp. 445-454
    • Meduri, G.U.1    Abou-Shala, N.2    Fox, R.C.3
  • 19
    • 0027407279 scopus 로고
    • Noninvasive pressure support ventilation in patients with acute respiratory failure
    • 19 Wysocki M, Trie L, Wolff MA, et al. Noninvasive pressure support ventilation in patients with acute respiratory failure. Chest 1993; 103:907-913
    • (1993) Chest , vol.103 , pp. 907-913
    • Wysocki, M.1    Trie, L.2    Wolff, M.A.3
  • 20
    • 0028968402 scopus 로고
    • Noninvasive pressure support ventilation in patients with acute respiratory failure: A randomized comparison with conventional therapy
    • 20 Wysocki M, Tric L, Wolff MA, et al. Noninvasive pressure support ventilation in patients with acute respiratory failure: a randomized comparison with conventional therapy. Chest 1995; 107:761-768
    • (1995) Chest , vol.107 , pp. 761-768
    • Wysocki, M.1    Tric, L.2    Wolff, M.A.3
  • 21
    • 0027126646 scopus 로고
    • Cost-effectiveness analysis
    • 21 Eddy DM. Cost-effectiveness analysis. JAMA 1992; 267: 1669-1675
    • (1992) JAMA , vol.267 , pp. 1669-1675
    • Eddy, D.M.1
  • 22
    • 0024472914 scopus 로고
    • Clinical economics
    • 22 Eisenberg JM. Clinical economics. JAMA 1989; 262:2879-2886
    • (1989) JAMA , vol.262 , pp. 2879-2886
    • Eisenberg, J.M.1
  • 23
    • 0030879788 scopus 로고    scopus 로고
    • A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifier: Rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion
    • 23 Kirton OC, DeHaven B, Morgan J, et al. A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifier: rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion. Chest 1997; 112:1055-1059
    • (1997) Chest , vol.112 , pp. 1055-1059
    • Kirton, O.C.1    DeHaven, B.2    Morgan, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.