메뉴 건너뛰기




Volumn 11, Issue 7, 1999, Pages 609-614

Entrapment of an exchange wire by an inferior vena caval filter: A technique for removal

Author keywords

Catheter, central venous: catheterization; Inferior vena cava: filter, guidewire

Indexed keywords

ADULT; ANESTHESIA COMPLICATION; ANESTHESIST; ARTICLE; CASE REPORT; CENTRAL VENOUS CATHETERIZATION; DEEP VEIN THROMBOSIS; FEMALE; FILTER; GUIDE WIRE; HUMAN; INFERIOR CAVA VEIN; PRIORITY JOURNAL; RECURRENT DISEASE; TECHNIQUE;

EID: 0032741909     PISSN: 09528180     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0952-8180(99)00111-7     Document Type: Article
Times cited : (8)

References (9)
  • 1
    • 0020081830 scopus 로고
    • Percutaneous central venous catheterization performed by medical house officers: A prospective study
    • Bo-Linn G.W., Anderson D.J., Anderson K.C., McGoon M.D. Percutaneous central venous catheterization performed by medical house officers a prospective study . Cathet Cardiovasc Diagn. 8:1982;23-29.
    • (1982) Cathet Cardiovasc Diagn , vol.8 , pp. 23-29
    • Bo-Linn, G.W.1    Anderson, D.J.2    Anderson, K.C.3    McGoon, M.D.4
  • 2
    • 0028208653 scopus 로고
    • Catheter placement and misplacement
    • Farshenas Z., Sparsch R.A. Catheter placement and misplacement. Crit Care Clin. 10:1994;417-436.
    • (1994) Crit Care Clin , vol.10 , pp. 417-436
    • Farshenas, Z.1    Sparsch, R.A.2
  • 3
    • 0028961196 scopus 로고
    • Twenty year clinical experience with the Greenfield filter
    • Greenfield L.J., Proctor M.C. Twenty year clinical experience with the Greenfield filter. Cardiovasc Surg. 3:1995;199-205.
    • (1995) Cardiovasc Surg , vol.3 , pp. 199-205
    • Greenfield, L.J.1    Proctor, M.C.2
  • 4
    • 0029915934 scopus 로고    scopus 로고
    • Current indications for caval interruption: Should they be liberalized in view of improving technology?
    • Greenfield L.J., Proctor M.C. Current indications for caval interruption should they be liberalized in view of improving technology? Semin Vasc Surg. 9:1996;50-58.
    • (1996) Semin Vasc Surg , vol.9 , pp. 50-58
    • Greenfield, L.J.1    Proctor, M.C.2
  • 6
    • 0027220378 scopus 로고
    • Dislodgement of inferior vena cava filters during blind insertion of central venous catheters
    • Loesberg A., Taylor F.C., Awh M.H. Dislodgement of inferior vena cava filters during blind insertion of central venous catheters. Am J Radiol. 161:1993;637-638.
    • (1993) Am J Radiol , vol.161 , pp. 637-638
    • Loesberg, A.1    Taylor, F.C.2    Awh, M.H.3
  • 7
    • 0029972811 scopus 로고    scopus 로고
    • Vena caval filter disruption and central migration due to accidental guidewire manipulation: A case report
    • Granke K., Abrahan M., McDowell D. Vena caval filter disruption and central migration due to accidental guidewire manipulation a case report . Am Vasc Surg. 10:1996;49-53.
    • (1996) Am Vasc Surg , vol.10 , pp. 49-53
    • Granke, K.1    Abrahan, M.2    McDowell, D.3
  • 8
    • 0344447081 scopus 로고    scopus 로고
    • "monorial technique" for removal of entrapped exchange wire in a Greenfield filter
    • Morgan T., Sussman S.K. "Monorial technique" for removal of entrapped exchange wire in a Greenfield filter. J Vasc Intervent Radiol. 9:1998;469-470.
    • (1998) J Vasc Intervent Radiol , vol.9 , pp. 469-470
    • Morgan, T.1    Sussman, S.K.2
  • 9
    • 0030066659 scopus 로고    scopus 로고
    • Guide wire entrapment by inferior vena caval filters: In vitro evaluation
    • Kaufman J.A., Thomas J.W., Geller S.C., Riuitz S.M., Waltman A.C. Guide wire entrapment by inferior vena caval filters in vitro evaluation . Radiology. 198:1996;71-76.
    • (1996) Radiology , vol.198 , pp. 71-76
    • Kaufman, J.A.1    Thomas, J.W.2    Geller, S.C.3    Riuitz, S.M.4    Waltman, A.C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.