메뉴 건너뛰기




Volumn 70, Issue 5, 1999, Pages 435-438

Type of screw does not influence holding power in the femoral head. A cadaver study with shearing test

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BIOMECHANICS; BONE SCREW; CADAVER; FEMUR HEAD; HUMAN; HUMAN TISSUE; WEIGHT BEARING;

EID: 0032740326     PISSN: 00016470     EISSN: None     Source Type: Journal    
DOI: 10.3109/17453679909000977     Document Type: Article
Times cited : (18)

References (11)
  • 1
    • 0026527438 scopus 로고
    • Implant holding power of the femoral head: A cadaver study of fracture screws
    • Benterud J G, Husby T, Graadahl O, Alho A. Implant holding power of the femoral head: a cadaver study of fracture screws. Acta Orthop Scand 1992; 63: 47-9.
    • (1992) Acta Orthop Scand , vol.63 , pp. 47-49
    • Benterud, J.G.1    Husby, T.2    Graadahl, O.3    Alho, A.4
  • 2
    • 0040421056 scopus 로고
    • Pull-out strength of fixation device in trabecular bone of the femoral head
    • Crowell R R, Edwards W T, Hayes W C. Pull-out strength of fixation device in trabecular bone of the femoral head. Trans Orthop Res Soc 1985; 10: 189-93.
    • (1985) Trans Orthop Res Soc , vol.10 , pp. 189-193
    • Crowell, R.R.1    Edwards, W.T.2    Hayes, W.C.3
  • 3
    • 0020606199 scopus 로고
    • Axial compression in femoral neck osteotomies. A biomechanical study in human cadaver hips
    • Frandsen P A, Madsen T. Axial compression in femoral neck osteotomies. A biomechanical study in human cadaver hips. Acta Orthop Scand 1983; 54: 703-7.
    • (1983) Acta Orthop Scand , vol.54 , pp. 703-707
    • Frandsen, P.A.1    Madsen, T.2
  • 5
    • 0027755888 scopus 로고
    • Le clou gamma dans le traitement à foyer fermé des fractures trochantériennes
    • Kempf I, Grosse A, Taglang G, Favreul E. Le clou gamma dans le traitement à foyer fermé des fractures trochantériennes. Rev Chir Orthop 1993 ; 79: 29-40.
    • (1993) Rev Chir Orthop , vol.79 , pp. 29-40
    • Kempf, I.1    Grosse, A.2    Taglang, G.3    Favreul, E.4
  • 6
    • 0025610224 scopus 로고
    • Holding power impaired in rheumatoid femoral heads. Cadaver study of fracture fixation devices
    • Larsson S, Elloy M. Holding power impaired in rheumatoid femoral heads. Cadaver study of fracture fixation devices. Acta Orthop Scand 1990; 61: 502-6.
    • (1990) Acta Orthop Scand , vol.61 , pp. 502-506
    • Larsson, S.1    Elloy, M.2
  • 7
    • 0031923934 scopus 로고    scopus 로고
    • Choice of implant for internal fixation of femoral neck fractures. Meta-analysis of 25 randomized trials including 4,925 patients
    • Parker M J, Blundell C. Choice of implant for internal fixation of femoral neck fractures. Meta-analysis of 25 randomized trials including 4,925 patients. Acta Orthop Scand 1998; 69: 138-43.
    • (1998) Acta Orthop Scand , vol.69 , pp. 138-143
    • Parker, M.J.1    Blundell, C.2
  • 9
    • 0024805207 scopus 로고
    • Fixation of femoral neck fractures. Comparison of the Uppsala and von Bahr screws
    • Rehnberg L, Olerud C. Fixation of femoral neck fractures. Comparison of the Uppsala and von Bahr screws. Acta Orthop Scand 1989; 60: 579-84.
    • (1989) Acta Orthop Scand , vol.60 , pp. 579-584
    • Rehnberg, L.1    Olerud, C.2
  • 10
    • 0025079902 scopus 로고
    • The AO dynamic hip screw and the Pugh sliding nail in femoral head fixation
    • Richards R H, Evans G, Egan J, Shearer S R. The AO dynamic hip screw and the Pugh sliding nail in femoral head fixation. J Bone Joint Surg (Br) 1990; 72: 794-6.
    • (1990) J Bone Joint Surg (Br) , vol.72 , pp. 794-796
    • Richards, R.H.1    Evans, G.2    Egan, J.3    Shearer, S.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.