메뉴 건너뛰기




Volumn 9, Issue 1-2, 1999, Pages 59-64

A volume adjustable four-coil phased array for high resolution MR imaging of the hip

Author keywords

Custom built RF coil; Fractures MRI; MRI physics; Phased array coil

Indexed keywords

ANALYTIC METHOD; ARTICLE; ARTICULAR CARTILAGE; DIAGNOSTIC VALUE; HIP FRACTURE; IMAGE ANALYSIS; IMAGE QUALITY; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL;

EID: 0032738208     PISSN: 13528661     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1352-8661(99)00045-9     Document Type: Article
Times cited : (16)

References (17)
  • 3
    • 0023950803 scopus 로고
    • MR imaging of avascular necrosis of the femoral head: Value of small field-of-vies sagittal surface-coil images
    • Shuman W.P., Castango A.A., Baron R.L., Richardson M.L. MR imaging of avascular necrosis of the femoral head: value of small field-of-vies sagittal surface-coil images. Am. J. Roentgenol. 150:1988;1073-1078.
    • (1988) Am. J. Roentgenol. , vol.150 , pp. 1073-1078
    • Shuman, W.P.1    Castango, A.A.2    Baron, R.L.3    Richardson, M.L.4
  • 6
    • 0029971679 scopus 로고    scopus 로고
    • Acetabular lateral tears: Contrast-enhanced MR imaging under continuous leg traction
    • Nishii T., Nakanishi K., Sugano N., Natto H., Tamura S., Ochi T. Acetabular lateral tears: contrast-enhanced MR imaging under continuous leg traction. Skeletal Radiol. 23:1996;349-356.
    • (1996) Skeletal Radiol. , vol.23 , pp. 349-356
    • Nishii, T.1    Nakanishi, K.2    Sugano, N.3    Natto, H.4    Tamura, S.5    Ochi, T.6
  • 7
    • 0026654868 scopus 로고
    • Width of the articular cartilage of the hip: Quantification by using fat-suppression spin-echo MR imaging in cadavers
    • Hodler J., Trudell D., Pathria M.N., Resnick D. Width of the articular cartilage of the hip: quantification by using fat-suppression spin-echo MR imaging in cadavers. Am. J. Roentgenol. 159:1992;351-355.
    • (1992) Am. J. Roentgenol. , vol.159 , pp. 351-355
    • Hodler, J.1    Trudell, D.2    Pathria, M.N.3    Resnick, D.4
  • 8
    • 0028940783 scopus 로고
    • MRI of the hip with a shoulder surface coil in off coronal plan. J Comput. Assist
    • Do-Dai D.D., Youngberg R.A. MRI of the hip with a shoulder surface coil in off coronal plan. J Comput. Assist. Tomography. 19:1995;336-338.
    • (1995) Tomography , vol.19 , pp. 336-338
    • Do-Dai, D.D.1    Youngberg, R.A.2
  • 9
    • 0023950803 scopus 로고
    • MR imaging of avascular necrosis of the femoral head: Value of small-field-of-view sagittal surface-coil images
    • Shuman W.P., Castagno A.A., Baron R.L., Richardson M.L. MR imaging of avascular necrosis of the femoral head: value of small-field-of-view sagittal surface-coil images. Am. J. Roentgenol. 150:1988;1073-1078.
    • (1988) Am. J. Roentgenol. , vol.150 , pp. 1073-1078
    • Shuman, W.P.1    Castagno, A.A.2    Baron, R.L.3    Richardson, M.L.4
  • 10
    • 0029084446 scopus 로고
    • MR arthrography of the hip: Improved imaging of the acetabular labrum with histologic correlation in cadavers
    • Hodler J., Yu J.S., Goodwin K., Haghighi P., Trudell D., Resnick D. MR arthrography of the hip: improved imaging of the acetabular labrum with histologic correlation in cadavers. Am. J. Roentgenol. 165:1995;887-891.
    • (1995) Am. J. Roentgenol. , vol.165 , pp. 887-891
    • Hodler, J.1    Yu, J.S.2    Goodwin, K.3    Haghighi, P.4    Trudell, D.5    Resnick, D.6
  • 14
    • 0026726218 scopus 로고
    • Multicoil high-resolution fast spin-echo MR imaging of the female pelvis
    • Smith R.C., Reinhold C., McCauley T.R. et al. Multicoil high-resolution fast spin-echo MR imaging of the female pelvis. Radiology. 184:1992;671-675.
    • (1992) Radiology , vol.184 , pp. 671-675
    • Smith, R.C.1    Reinhold, C.2    McCauley, T.R.3
  • 15
    • 0026858273 scopus 로고
    • Pelvic imaging with phased-array coils: Quantitative assessment of signal-to-noise ratio improvement
    • Hayes C.E., Dietz M.J., King B.F., Ehman R.L. Pelvic imaging with phased-array coils: quantitative assessment of signal-to-noise ratio improvement. J. Magn. Reson. Imaging. 2:1992;321-326.
    • (1992) J. Magn. Reson. Imaging , vol.2 , pp. 321-326
    • Hayes, C.E.1    Dietz, M.J.2    King, B.F.3    Ehman, R.L.4
  • 16
    • 0030276940 scopus 로고    scopus 로고
    • High resolution MR imaging of the bilateral hips with dual phased-array coil
    • Niitsu M., Mishima H., Miyakawa S., Itali Y. High resolution MR imaging of the bilateral hips with dual phased-array coil. J. Magn. Reson. Imaging. 6:1996;950-953.
    • (1996) J. Magn. Reson. Imaging , vol.6 , pp. 950-953
    • Niitsu, M.1    Mishima, H.2    Miyakawa, S.3    Itali, Y.4
  • 17
    • 0031953078 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the hip with pelvic phased array surface coil
    • Rubin S.J., Totterman S.M.S., Meyers S.P., Hartley D.F. Magnetic resonance imaging of the hip with pelvic phased array surface coil. Skeletal Radiol. 27(2):1998;77-82.
    • (1998) Skeletal Radiol. , vol.27 , Issue.2 , pp. 77-82
    • Rubin, S.J.1    Totterman, S.M.S.2    Meyers, S.P.3    Hartley, D.F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.