Volumn 25, Issue 11, 1999, Pages 1498-1504

Identification of intraocular lens materials using confocal Raman spectroscopy

Author keywords

[No Author keywords available]

Indexed keywords

POLY(METHYL METHACRYLATE); SILICONE;

EID: 0032738020     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0886-3350(99)00239-4     Document Type: Article
Times cited : (6)

References (19)
  • 1
    • 0001461186 scopus 로고
    • Intra-ocular acrylic lenses
    • Ridley N.H.L. Intra-ocular acrylic lenses. Trans Ophthalmol Soc UK. 71:1951;617-621.
    • (1951) Trans Ophthalmol Soc UK , vol.71 , pp. 617-621
    • Ridley, N.H.L.1
  • 2
    • 0030905175 scopus 로고    scopus 로고
    • Folding intraocular lenses: Materials and methods
    • Seward H.C. Folding intraocular lenses materials and methods . Br J Ophthalmol. 81:1997;340-341.
    • (1997) Br J Ophthalmol , vol.81 , pp. 340-341
    • Seward, H.C.1
  • 3
    • 0028012219 scopus 로고
    • A new hydrogel intraocular lens design
    • Barrett G.D. A new hydrogel intraocular lens design. J Cataract Refract Surg. 20:1994;18-25.
    • (1994) J Cataract Refract Surg , vol.20 , pp. 18-25
    • Barrett, G.D.1
  • 4
    • 0023405162 scopus 로고
    • Silicone intraocular lenses during vitrectomy
    • (letter)
    • Glickman G.M., Poole T.A. Silicone intraocular lenses during vitrectomy. (letter) Arch Ophthalmol. 105:1987;1166.
    • (1987) Arch Ophthalmol , vol.105 , pp. 1166
    • Glickman, G.M.1    Poole, T.A.2
  • 5
    • 0029021732 scopus 로고
    • Condensation on the posterior surface of silicone intraocular lenses during fluid-air exchange
    • Eaton A.M., Jaffe G.J., McCuen B.W. II, Mincey G.J. Condensation on the posterior surface of silicone intraocular lenses during fluid-air exchange. Ophthalmology. 102:1995;733-736.
    • (1995) Ophthalmology , vol.102 , pp. 733-736
    • Eaton, A.M.1    Jaffe, G.J.2    McCuen B.W. II3    Mincey, G.J.4
  • 6
    • 0029807432 scopus 로고    scopus 로고
    • Condensation on polymethylmethacrylate, acrylic polymer, and silicone intraocular lenses after fluid-air exchange in rabbits
    • Hainsworth D.P., Chen S.N., Cox T.A., Jaffe G.J. Condensation on polymethylmethacrylate, acrylic polymer, and silicone intraocular lenses after fluid-air exchange in rabbits. Ophthalmology. 103:1996;1410-1418.
    • (1996) Ophthalmology , vol.103 , pp. 1410-1418
    • Hainsworth, D.P.1    Chen, S.N.2    Cox, T.A.3    Jaffe, G.J.4
  • 7
    • 0029380782 scopus 로고
    • Posterior condensation on silicone IOLs
    • (letter)
    • Kutner B.N. Posterior condensation on silicone IOLs. (letter) Ophthalmology. 102:1995;1412.
    • (1995) Ophthalmology , vol.102 , pp. 1412
    • Kutner, B.N.1
  • 9
    • 0029858961 scopus 로고    scopus 로고
    • Irreversible silicone oil adhesion to silicone intraocular lenses; A clinicopathologic analysis
    • Apple D.J., Federman J.L., Krolicki T.J., et al. Irreversible silicone oil adhesion to silicone intraocular lenses; a clinicopathologic analysis. Ophthalmology. 103:1996;1555-1561.
    • (1996) Ophthalmology , vol.103 , pp. 1555-1561
    • Apple, D.J.1    Federman, J.L.2    Krolicki, T.J.3
  • 11
    • 0030904755 scopus 로고    scopus 로고
    • Silicone oil adhesion to intraocular lenses; An experimental study comparing various biomaterials
    • Apple D.J., Isaacs R.T., Kent D.G., et al. Silicone oil adhesion to intraocular lenses; an experimental study comparing various biomaterials. J Cataract Refract Surg. 23:1997;536-544.
    • (1997) J Cataract Refract Surg , vol.23 , pp. 536-544
    • Apple, D.J.1    Isaacs, R.T.2    Kent, D.G.3
  • 12
    • 0031596652 scopus 로고    scopus 로고
    • Biocompatibility of poly(methyl methacrylate), silicone, and AcrySof intraocular lenses: Randomized comparison of the cellular reaction on the anterior lens surface
    • Hollick E.J., Spalton D.J., Ursell P.G., Pande M.V. Biocompatibility of poly(methyl methacrylate), silicone, and AcrySof intraocular lenses randomized comparison of the cellular reaction on the anterior lens surface . J Cataract Refract Surg. 24:1998;361-366.
    • (1998) J Cataract Refract Surg , vol.24 , pp. 361-366
    • Hollick, E.J.1    Spalton, D.J.2    Ursell, P.G.3    Pande, M.V.4
  • 13
    • 0020317373 scopus 로고
    • Direct measurement of Raman spectra of intact lens in a whole eyeball
    • Mizuno A, Ozaki Y, Kamada Y, et al. Direct measurement of Raman spectra of intact lens in a whole eyeball. Curr Eye Res 1981/1982; 1:609-613.
    • (1981) Curr Eye Res , vol.1 , pp. 609-613
    • Mizuno, A.1    Ozaki, Y.2    Kamada, Y.3
  • 14
    • 0001455809 scopus 로고
    • Raman spectroscopy studies of metabolic concentrations in aqueous solutions and aqueous humor specimens
    • Wicksted J.P., Erckens R.J., Motamedi M., March W.F. Raman spectroscopy studies of metabolic concentrations in aqueous solutions and aqueous humor specimens. Appl Spectrosc. 49:1995;987-993.
    • (1995) Appl Spectrosc , vol.49 , pp. 987-993
    • Wicksted, J.P.1    Erckens, R.J.2    Motamedi, M.3    March, W.F.4
  • 15
    • 0031977706 scopus 로고    scopus 로고
    • Noninvasive assessment of the hydration gradient across the cornea using confocal Raman spectroscopy
    • Bauer N.J.C., Wicksted J.P., Jongsma F.H.M., et al. Noninvasive assessment of the hydration gradient across the cornea using confocal Raman spectroscopy. Invest Ophthalmol Vis Sci. 39:1998;831-835.
    • (1998) Invest Ophthalmol Vis Sci , vol.39 , pp. 831-835
    • Bauer, N.J.C.1    Wicksted, J.P.2    Jongsma, F.H.M.3
  • 16
    • 0032935622 scopus 로고    scopus 로고
    • Non-invasive assessment of ocular pharmacokinetics using confocal Raman spectroscopy
    • Bauer N.J.C., Motamedi M., Wicksted J.P., et al. Non-invasive assessment of ocular pharmacokinetics using confocal Raman spectroscopy. J Ocular Pharm Ther. 15:1999;123-134.
    • (1999) J Ocular Pharm Ther , vol.15 , pp. 123-134
    • Bauer, N.J.C.1    Motamedi, M.2    Wicksted, J.P.3
  • 17
    • 0001482580 scopus 로고    scopus 로고
    • Confocal Raman spectroscopy system for non-contact scanning of ocular tissues: An in vitro study
    • Jongsma F.H.M., Erckens R.J., Wicksted J.P., et al. Confocal Raman spectroscopy system for non-contact scanning of ocular tissues an in vitro study . Opt Eng. 36:1997;3193-3199.
    • (1997) Opt Eng , vol.36 , pp. 3193-3199
    • Jongsma, F.H.M.1    Erckens, R.J.2    Wicksted, J.P.3
  • 19
    • 0029329088 scopus 로고
    • Application of a multivariate technique to Raman spectra for quantification of body chemicals
    • Goetz M.J. Jr, Coté G.L., et al. Application of a multivariate technique to Raman spectra for quantification of body chemicals. IEEE Trans Biomed Eng. 42:1995;728-731.
    • (1995) IEEE Trans Biomed Eng , vol.42 , pp. 728-731
    • Goetz M.J., Jr.1    Coté, G.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.