메뉴 건너뛰기




Volumn 68, Issue 2, 1999, Pages 421-425

Aortic Carpentier-Edwards supraannular porcine bioprosthesis: A 12-year experience

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; AGING; AORTA STENOSIS; BIOPROSTHESIS; CONFERENCE PAPER; FEMALE; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; HUMAN; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; PROSTHESIS FAILURE; REOPERATION; RISK ASSESSMENT; SURGICAL MORTALITY; SURVIVAL RATE; SWINE;

EID: 0032737389     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0003-4975(99)00517-2     Document Type: Conference Paper
Times cited : (18)

References (20)
  • 1
    • 0029126789 scopus 로고
    • Carpentier-Edwards supraannular porcine bioprosthesis: Clinical performance to twelve years
    • Jamieson WRE, Burr LH, Tyers GFO, et al. Carpentier-Edwards supraannular porcine bioprosthesis: clinical performance to twelve years. Ann Thorac Surg 1995;60:S235-40.
    • (1995) Ann Thorac Surg , vol.60
    • Jamieson, W.R.E.1    Burr, L.H.2    Tyers, G.F.O.3
  • 2
    • 0028631884 scopus 로고
    • Surgery for aortic stenosis in elderly patients. A study of surgical risk and predictive factors
    • Logeais Y, Langanay T, Roussin R, et al. Surgery for aortic stenosis in elderly patients. A study of surgical risk and predictive factors. Circulation 1994;90:2891-8.
    • (1994) Circulation , vol.90 , pp. 2891-2898
    • Logeais, Y.1    Langanay, T.2    Roussin, R.3
  • 3
    • 18544404667 scopus 로고
    • Aortic valve replacement for aortic stenosis in 200 consecutive octogenarians
    • Logeais Y, Roussin R, Langanay T, et al. Aortic valve replacement for aortic stenosis in 200 consecutive octogenarians. J Heart Valve Dis 1995;4:(Suppl 1):64-71.
    • (1995) J Heart Valve Dis , vol.4 , Issue.1 SUPPL. , pp. 64-71
    • Logeais, Y.1    Roussin, R.2    Langanay, T.3
  • 4
    • 0030248226 scopus 로고    scopus 로고
    • Guidelines for reporting morbidity and mortality after cardiac valvular operations
    • Edmunds LH Jr, Clark RE, Cohn LH, et al. Guidelines for reporting morbidity and mortality after cardiac valvular operations. Ann Thorac Surg 1996;62:932-5.
    • (1996) Ann Thorac Surg , vol.62 , pp. 932-935
    • Edmunds L.H., Jr.1    Clark, R.E.2    Cohn, L.H.3
  • 5
    • 0024723917 scopus 로고
    • The expected lifetime of porcine valves
    • Starr A, Grunkemeier GL. The expected lifetime of porcine valves. Ann Thorac Surg 1989;48:317-8.
    • (1989) Ann Thorac Surg , vol.48 , pp. 317-318
    • Starr, A.1    Grunkemeier, G.L.2
  • 6
    • 0023801814 scopus 로고
    • Carpentier-Edwards standard porcine bioprosthesis. Primary tissue failure (structural valve deterioration) by age groups
    • Jamieson WRE, Rosado LJ, Munro AL, et al. Carpentier-Edwards standard porcine bioprosthesis. Primary tissue failure (structural valve deterioration) by age groups. Ann Thorac Surg 1988;46:155-62.
    • (1988) Ann Thorac Surg , vol.46 , pp. 155-162
    • Jamieson, W.R.E.1    Rosado, L.J.2    Munro, A.L.3
  • 7
    • 0024457448 scopus 로고
    • The porcine bioprosthetic heart valve: Experience at 15 years
    • Magilligan DJ, Lewis JW, Stein P, et al. The porcine bioprosthetic heart valve: experience at 15 years. Ann Thorac Surg 1989;48:324-30.
    • (1989) Ann Thorac Surg , vol.48 , pp. 324-330
    • Magilligan, D.J.1    Lewis, J.W.2    Stein, P.3
  • 10
    • 0025254212 scopus 로고
    • Ten-year experience with the porcine bioprosthetic valve: Interrelationship of valve survival and patient survival in 1050 valve replacements
    • Jones EL, Weintraub WS, Craver JM, et al. Ten-year experience with the porcine bioprosthetic valve: interrelationship of valve survival and patient survival in 1050 valve replacements. Ann Thorac Surg 1990;49:370-84.
    • (1990) Ann Thorac Surg , vol.49 , pp. 370-384
    • Jones, E.L.1    Weintraub, W.S.2    Craver, J.M.3
  • 11
    • 0026550699 scopus 로고
    • Durability of porcine valves at fifteen years in a representative North American patient population
    • Burdon TA, Miller DC, Oyer PE, et al. Durability of porcine valves at fifteen years in a representative North American patient population. J Thorac Cardiovasc Surg 1992;103: 238-52.
    • (1992) J Thorac Cardiovasc Surg , vol.103 , pp. 238-252
    • Burdon, T.A.1    Miller, D.C.2    Oyer, P.E.3
  • 12
    • 0026749514 scopus 로고
    • Influence of age on late results of valve replacement with porcine bioprostheses
    • Pelletier LC, Carrier M, Leclerc Y, et al. Influence of age on late results of valve replacement with porcine bioprostheses. J Cardiovasc Surg 1992;33:526-33.
    • (1992) J Cardiovasc Surg , vol.33 , pp. 526-533
    • Pelletier, L.C.1    Carrier, M.2    Leclerc, Y.3
  • 13
    • 0027359442 scopus 로고
    • Randomized, prospective assessment of bioprosthetic valve durability
    • Sarris GE, Robbins RC, Miller DC, et al. Randomized, prospective assessment of bioprosthetic valve durability. Circulation 1993;88:55-64.
    • (1993) Circulation , vol.88 , pp. 55-64
    • Sarris, G.E.1    Robbins, R.C.2    Miller, D.C.3
  • 14
    • 0028038849 scopus 로고
    • Carpentier-Edwards standard and supra-annular porcine bioprostheses: 10 year comparison of structural valve deterioration
    • Jamieson WRE, Burr LH, Tyers GFO, Munro AI. Carpentier-Edwards standard and supra-annular porcine bioprostheses: 10 year comparison of structural valve deterioration. J Heart Valve Dis 1994;3:59-65.
    • (1994) J Heart Valve Dis , vol.3 , pp. 59-65
    • Jamieson, W.R.E.1    Burr, L.H.2    Tyers, G.F.O.3    Munro, A.I.4
  • 15
    • 0029123705 scopus 로고
    • Structural deterioration in Carpentier-Edwards. Standard and supraannular porcine bioprostheses
    • Jamieson WR, Burr LH, Miyagishima RT, et al. Structural deterioration in Carpentier-Edwards. Standard and supraannular porcine bioprostheses. Ann Thorac Surg 1995;60: S241-7.
    • (1995) Ann Thorac Surg , vol.60
    • Jamieson, W.R.1    Burr, L.H.2    Miyagishima, R.T.3
  • 16
    • 0029088675 scopus 로고
    • Bioprosthetic valve longevity in the elderly: An 18-year longitudinal study
    • Pupello DF, Bessone LN, Hiro SP, et al. Bioprosthetic valve longevity in the elderly: an 18-year longitudinal study. Ann Thorac Surg 1995;60:S270-5.
    • (1995) Ann Thorac Surg , vol.60
    • Pupello, D.F.1    Bessone, L.N.2    Hiro, S.P.3
  • 17
    • 0029122702 scopus 로고
    • Durability of the Hancock MO bioprosthesis compared with standard aortic valve bioprostheses
    • Yun KL, Miller DC, Moore KA, et al. Durability of the Hancock MO bioprosthesis compared with standard aortic valve bioprostheses. Ann Thorac Surg 1995;60:S221-8.
    • (1995) Ann Thorac Surg , vol.60
    • Yun, K.L.1    Miller, D.C.2    Moore, K.A.3
  • 19
    • 0028189612 scopus 로고
    • The Carpentier-Edwards pericardial aortic valve: Intermediate results in 420 patients
    • Aupart M, Neville P, Dreyfus X, et al. The Carpentier-Edwards pericardial aortic valve: intermediate results in 420 patients. Eur J Cardiothorac Surg 1994;8:277-80.
    • (1994) Eur J Cardiothorac Surg , vol.8 , pp. 277-280
    • Aupart, M.1    Neville, P.2    Dreyfus, X.3
  • 20
    • 0028857246 scopus 로고
    • Comparative assessment of bioprosthesis durability in the aortic position
    • Grunkemeier GL, Bodnar E. Comparative assessment of bioprosthesis durability in the aortic position. J Heart Valve Dis 1995;4:49-55.
    • (1995) J Heart Valve Dis , vol.4 , pp. 49-55
    • Grunkemeier, G.L.1    Bodnar, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.